FL
SWITCH
EP74…
PHOENIX CONTACT
4083_en_A
Electrostatic discharge
IEC 61850-3 clause 6.7.3, IEC 61000-4-2,
IEEE 1613 clause 8, IEEE 1613.1 clause 8,
8
kV contact 15
kV air
Radiated radio frequency magnetic field
IEC 61850-3 clause 6.7.3, IEC 61000-4-3,
IEEE 1613 clause 7, IEEE 1613.1 clause 7,
20
V/m
Fast transient/burst
IEC 61850-3 clause 6.7.3, IEC 61000-4-4,
IEEE 1613 clause 6, IEEE 1613.1 clause 5,
4
kV
Surge
IEC 61850-3 clause 6.7.3, IEC 61000-4-5,
IEEE 1613.1 clause 6
Signal ports: ±2 kV LE, ±1 kV LL
Power ports (AC or DC): ±4
kV LE, ±2 kV LL
Conducted disturbance induced by RF fields
IEC 61850-3 clause 6.7.3, IEC 61000-4-6, IEEE 1613.1
clause 9, 10 V
Main frequency voltage, common mode disturbances
IEC 61850-3 clause 6.7.3, IEC 61000-4-16, IEEE 1613.1
clause 12, 30
V continuous, 300
V 1 s
Power frequency magnetic field
IEC 61850-3 clause 6.7.3, IEC 61000-4-8, IEEE 1613.1
clause 10, 100 A/m continuous, 1000 A/m for 3 s
Voltage dips and drops (AC/DC)
IEC 61850-3 clause 6.7.3, IEC 61000-4-29, IEC 61000-4-11
Damped oscillatory magnetic field
IEEE 1613.1 clause 11, IEC 61000-4-10, 100 A/m (peak)
Flammability
V1, IEC 61850-3 clause 6.6.6
Environmental specifications and approvals according to IEC 61850-3 Ed 2, IEEE 1613
Summary of Contents for 1144175
Page 1: ...User manual UM EN FL SWITCH EP74 HDWE Hardware and installation for FL SWITCH EP74...
Page 24: ...FL SWITCH EP74 24 40 PHOENIX CONTACT 4083_en_A...
Page 34: ...FL SWITCH EP74 34 40 PHOENIX CONTACT 4083_en_A...
Page 36: ...FL SWITCH EP74 36 40 PHOENIX CONTACT 4083_en_A...
Page 38: ...FL SWITCH EP74 38 40 PHOENIX CONTACT 4083_en_A...