FL
SWITCH
EP74…
PHOENIX CONTACT
4083_en_A
4.5
Connections
Voltage supply conductors are connected directly to the rear of the switch, not the power
supply modules.
WARNING:
Ensure the voltage supply is turned off before connecting the voltage supply conduc-
tors to the terminals on the switch.
Disconnect all power sources. Device may have multiple power sources.
Ensure the supplied terminal block cover is installed before reapplying power.
NOTE:
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
(+/L)
(-/N)
PWR 1
PWR2
Alarm Relay
24VDC, 1A
Options
(+/L)
(-/N)
NO NC C
HV Specs: 100-240 VAC, 1A, 50/60Hz, 100-240 VDC, 1A
MV Specs: 48 VDC, 1.25A
LV Specs: 24 VDC, 2.5A
Do not connect AC power cables to the FL SWITCH EP7400-PS-MV or FL SWITCH
EP7400-PS-LV modules. Discard and replace modules if this occurs.
Figure
4-5
Terminal block connections
4.5.1
AC power
1
3
5
7
9
11
13
15
2
4
6
8
10
12
14
16
NO
PE
PE
PE
L
N
NC
L
AC
N
AC
L = Line
N = Neutral
PE = Protective earth
NO = Normally open
NC = Normally closed
Figure
4-6
AC power connections
For 100-240 V AC rated equipment, protection for earth fault is provided by a 20
A maximum
branch circuit from AC input in the building installation. The protection in the building instal-
lation is relied upon for short-circuit backup protection.
–
The specification for AC breaker is 5
A, 2P, 277
V
AC (min) circuit breaker, thermomag-
netic or equivalent type.
–
The plug connector and wire gauge sizing is to be selected with appropriate design as
per the electrical code for a 60
W, 1-phase device.
All equipment must be installed according to applicable local wiring codes and standards.
Summary of Contents for 1144175