No dimming
Dimming is on
Load off
Load hours
on
on
off
Dimming hours
on
off
N/A
Dimming output voltage
10 V
Voltage proportional to adjusted
dimming value
0 V
Corresponding relationship of 'Output voltage' and 'Dimming value'
Output voltage
0 V
1 V
2 V
3 V
4 V
5 V
6 V
7 V
8 V
9 V
10 V
Dimming value*
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
* : +/- 3% tolerance
Testing Function
Pushing the test button on the CIS-CU (Control Unit) will switch on load terminal for 1 minute.
Should pressing the button cause a load disconnect event (LVD/SOC, over current) then the load will be switched off immediately.
Safety Features
PV terminal
Battery terminal
Load terminal
Reverse polarity
Protected (1)
Not protected (2)
Protected (3)
Short circuit (4)
Protected
Protected (5)
Switches off immediately
Overcurrent
Limited
---
Switches off with a delay (6)
Reverse current
Protected (7)
---
---
Overvoltage
Max. 50 V (8)
Max. 50 V
Switches off above 15.5/31.0 V
19
Summary of Contents for CIS-MPPT 50/10
Page 6: ...4 Zum Kontroll Dimm Steuer eingang der LED Treiber Erdungs Stelle Sich erung...
Page 18: ...16 Connect to dimming control terminal of LED Driver Grounding post Fuse...
Page 42: ...40 Connectez au terminal de contr le du gradateur du pilote LED Mise la terre Fusi ble...
Page 54: ...52 Conecte ao terminal de controle de luminosidade do LED Driver Ponto de aterramento Fus vel...
Page 63: ...CIS MPPT 50 10 IP68 1 5 m 72 CIS CU 4 3 12 24 V CIS MPPT 50 10 61...
Page 64: ...CE CE MPPT 98 IP68 40 C 60 C 62...
Page 66: ...64...
Page 67: ...CIS MPPT 50 10 3 65...
Page 68: ...0 V 10 V 1 V 1000 Ohm CIS CU 1 CIS CU 2 N A 10 V 0 V 66...
Page 71: ...8 0 16 0 V 1 0 h 0 h 0 h 0 h 50 1 1 5 3 0 V 69...
Page 74: ...20140715 Phocos AG Germany www phocos com 72 ISO9001 RoHS...