ENGLISH

6

  The power supply cord cannot be replaced by the user. In case the power supply cord 

becomes damaged, contact Philips Respironics customer service for replacement (there  
is no service option).

  This device is for continuous use. Failure to operate appropriately may lead to  

device damage.

  Before performing any cleaning operation or filter replacement, disconnect the device from 

the main supply by unplugging it.

  Small parts can be inhaled, swallowed or dangerous. Cable, due to its length, may result in 

provoking strangulation or asphyxiation. Do not leave the device alone with a small child or 
physically challenged individual or an individual with learning difficulties.

  If you no longer use the device, dispose of according to the local regulations in force.

  Remember to:

•  Use only manufactured-supplied original accessories and components;
•  Do not use accessories, detachable parts and materials not described in these 

instructions for use;

•  Do not interconnect this equipment to other equipment not described in these 

instructions for use;

•  Use the accessories recommended by your doctor.

  Use of accessories other than manufactured-supplied original accessories could result 

in increased electromagnetic emissions or decreased electromagnetic immunity of this 
equipment and result in improper operation.

  This device is for indoor use only, device might not offer adequate protection to radio-

frequency communication services. The user might need to take mitigation measures, such 
as relocating or re-orienting the equipment.

 This device is not a toy. Do not use it as a toy.

Device safety system

Thermal protector

The device contains a thermal protector which will turn the device OFF if it overheats.

ATTENTION:

 Should the unit overheat, and the thermal protector activates, switch the unit 

to the off "O" position, then allow the device to cool down for at least 40 minutes before 
switching the unit back on.

  Electromagnetic information: Portable and RF communication devices such as cellular 

phones, pagers, etc. can interrupt operation of electrical medical equipment. For this 
reason, your compressor must be placed far enough away from these devices to prevent 
interference (no closer than 30cm/12 inches). This device meets IEC60601-1-2 standard 
for electromagnetic compatibility (EMC). 

  In case of failure and/or malfunction, read the “Troubleshooting” section. Do not open the 

compressor housing as this is not a serviceable product.

10

  The proper function of the device can be compromised if original replacement parts  

(e.g., filters) are not used.

11

  To reduce risk of electric shock, DO NOT DISASSEMBLE.

12

  Indoor use only.

13

  Do not use the device without the filter.

14

  Make sure that the electrical rating shown on the rating label on the bottom of the unit 

corresponds to your main voltage and frequency before plugging in the device.

15

  When using any electrical appliance, certain important safety measures must always be 

followed, including the following:

•  Use only manufactured-supplied original accessories and components;
• Never submerge the unit in water as the device is not protected against water penetration;
•  Never touch the unit when your hands are wet or moist;
•  Do not leave the unit outdoors;
• Place on a stable and horizontal surface when operating;
•  Make sure the air vent openings are not obstructed; never place the product on a soft 

surface, such as a bed or couch, where the air openings may be blocked. Keep the air 
openings free of lint, hair, and the like;

•  Do not allow unsupervised children or infirm individuals to use the unit;
• Do not turn off the unit by simply pulling out the plug from the electrical outlet;
•  Do not use in a ventilator circuit;
•  Do not use if the device has cracks or is damaged;
• Never drop or insert any object into any openings;
•  Do not position the product on an uneven surface or where it is difficult to disconnect  

the plug.

16

  Do not use any adapter, single or multiple, and/or extension cord.

  Do not leave the unit plugged in when not in use. Unplug the device from the electrical 

outlet when not in operation.

  Follow the manufacturer’s instructions for installing the device. The manufacturer cannot be 

held responsible for any damage caused by incorrect installation.

1133807R01_WillisTheWhaleCompressor_EN_SP_IFU_3.indd   6-7

6/8/17   1:25 PM

Summary of Contents for Willis the Whale

Page 1: ...Willis the Whale Compressor nebulizer system 1133807R01_WillisTheWhaleCompressor_EN_SP_IFU_3 indd 1 6 8 17 1 25 PM ...

Page 2: ...3 Index English EN 4 Español ES 14 1133807R01_WillisTheWhaleCompressor_EN_SP_IFU_3 indd 2 3 6 8 17 1 25 PM ...

Page 3: ...caused by improper incorrect or unreasonable use or if the unit is connected to electrical installations not complying with safety regulations It is recommended to have a backup device e g MDI or battery operated compressor for respiratory delivery in case a situation arises when your nebulizer cannot be used e g during a power outage or if your compressor becomes inoperable for any reason If the ...

Page 4: ... of electrical medical equipment For this reason your compressor must be placed far enough away from these devices to prevent interference no closer than 30cm 12 inches This device meets IEC60601 1 2 standard for electromagnetic compatibility EMC In case of failure and or malfunction read the Troubleshooting section Do not open the compressor housing as this is not a serviceable product 10 The pro...

Page 5: ...6 kPa Noise level 60 dBA at 3 25 feet Instructions for use Remove the compressor from carrying case if supplied before use After unpacking the device check the compressor and accessories for visible damage or defects such as cracks in the plastic housing which could expose electrical components Contact Philips Respironics customer service or your product distributor to report any damaged product W...

Page 6: ...trical hazards DOUBLE INSULATED The nebulizer mouthpiece nebulizer medication cup nebulizer tubing mask if used and On Off switch are applied parts Warranty Philips Respironics Inc warrants the Willis the Whale compressor nebulizer system to be free from defects in materials and workmanship under normal use and operation for a period of 5 years from date of purchase from Philips Respironics Inc Th...

Page 7: ... off from normal level it may be necessary to use uninterruptible power supply or a battery Power frequency 50 60Hz magnetic field IEC 61000 4 8 Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment 6 Radiated RF EM fields IEC 61000 4 3 10V m 80MHz 2 7GHz 80 AM at 1kHz 10V m 80MHz 2 7GHz 80 AM at 1kHz 3V 0 15MHz 80M...

Page 8: ...ponsable por los daños causados por el uso impropio incorrecto o irrazonable o si la unidad se ha conectado a instalaciones eléctricas que no cumplen con las reglamentaciones de seguridad Se recomienda contar con un equipo de reserva por ejemplo un inhalador de dosis medidas MDI o compresor de funcionamiento a pila para la entrega respiratoria en caso de surgir una situación en que el nebulizador ...

Page 9: ...ito de ventilación no lo use si el dispositivo tiene grietas o está dañado nunca deje caer ni inserte ningún objeto en las aberturas no coloque el producto sobre una superficie irregular o en lugares donde sea difícil desconectar el enchufe 16 No use un adaptador ya sea simple o múltiple y o una extensión eléctrica No deje la unidad enchufada mientras no la use Desenchufe el dispositivo del tomaco...

Page 10: ...deben ser reemplazados de acuerdo con sus instrucciones Remplazo del filtro remplace el filtro cuando esté sucio o húmedo Los filtros de repuesto están disponibles donde usted compró este producto paquete de 5 número de repuesto 1083128 Para cambiar el filtro haga girar la tapa del filtro y quite el filtro jalando el filtro debe reemplazarse cuando esté descolorido No lave ni vuelva a usar el filt...

Page 11: ...ales por un período de 5 años desde la fecha de la compra a Philips Respironics Inc La garantía se limita a reparar o reemplazar a opción exclusiva de Philips Respironics Inc cualquier componente o equipo considerado como defectuoso cuando se demuestre que la reclamación es de buena fe según la evaluación hecha por Philips Respironics Inc Esta garantía no se extiende a los componentes o equipos so...

Page 12: ...rica 50 60 Hz campo magnético IEC 61000 4 8 Los campos magnéticos de la frecuencia eléctrica deben estar a los niveles característicos de una localización típica en un ambiente comercial u hospitalario típico 6 Campos irradiados RF EM IEC 61000 4 3 10V m 80MHz 2 7GHz 80 AM a 1kHz 10V m 80MHz 2 7GHz 80 AM a 1kHz 3V 0 15MHz 80MHz 6V en ISM y bandas de radioaficionados entre 0 15MHz y 80MHz 80 AM a 1...

Page 13: ... Nivel de prueba de INMUNIDAD V m Nivel de conformidad 385 380 390 TETRA 400 Modulación de impulsos 18 Hz 1 8 0 3 27 27 450 430 470 GMRS 460 FRS 460 FMc 5kHz de desviación 1 kHz seno 2 0 3 28 28 710 745 780 704 787 LTE Banda 13 17 Modulación de impulsos 217 Hz 0 2 0 3 9 9 810 870 930 800 960 GSM 800 900 TETRA 800 Iden 820 CDMA 850 LTE Banda 5 Modulación de impulsos 18 Hz 2 0 3 28 28 1720 1845 1970...

Page 14: ...1133807R01_WillisTheWhaleCompressor_EN_SP_IFU_3 indd 26 27 6 8 17 1 25 PM ...

Page 15: ...ronics Inc and Respironics Respiratory Drug Delivery UK Ltd are Philips companies Made in China Manufactured for Respironics Respiratory Drug Delivery UK Ltd Chichester Business Park City Fields Way Tangmere Chichester PO20 2FT UK www philips com respironics PN 1133807 R01 1133807R01_WillisTheWhaleCompressor_EN_SP_IFU_3 indd 28 6 8 17 1 25 PM ...

Reviews: