EN8
WelcomeEye Connect 2 / Touch / V1
4. Installation of the main or additional intercom panel
*
Note:
The product must not be connected to the power supply before the wiring has been
completed.
DES 9900 VDP
5
1 0 0 6
3
1 2 3 4 5 6
1
2
7 8
1
2
1
2
DES 9901 VDP
5
1 0 0 6
3
M
ad
e
in
P
.R
.C
IP44
20V 110mA
RFID 125kHz
1m60
1
1
2
2
1
2
4
7
5
3
6
8
9
Avidsen
19 avenue Marcel Dassault
37200 TOURS
FRANCE
1 - Remove the tamper-resistant screw from the intercom panel.
2 - Tip the intercom panel cover forward.
3 – The intercom’s lens should be approximately 1.60m above the ground.
4 – Mark the locations.
5 - Drill.
6 - Use pegs adapted to the nature of the support (the screws supplied are suitable for
solid walls).
7 – Connect the two wires from the monitor and, if necessary, connect the electric strike
plate and the gate (see section 1. Wiring). Configure the switches at the back of the
intercom panel (see section 2. Configuring the intercom).
8 – Insert the screws and refit the two caps concealing the retaining screws.
Note:
screw through the black covers on the back of the intercom panel without removing them.