Technical specifications

0

System monitor

Picture tube

14", 90° deflection, 0.65mm pitch TV grade

Resolution (Line pairs)

340 TVL

TV standard

PAL, 625 lines, 50Hz, 2:1

Mains supply voltage

100 - 240V

AC

+/-10%, 50/60Hz

Power consumption

70W max. (without cameras)
110W max. (with 4 cameras at 200m.)

Camera power supply

16-32V

DC

, short-circuit protected

System synchronisation

Monitor locks to the mains
Cameras lock to H and V of the monitor

Camera inputs

4 (system interface)

Slave monitor output

1 (system interface)

Microphone

electret

Frequence range

300 - 3kHz

Alarm output

4-pole screwblock

N.O./N.C. c system ground

Contact rating

24V

DC

, 2A

VCR

Video input

BNC (1Vpp, input impedance 75Ohm)

Audio input

Cinch (0.5Vpp, input impedance 10kOhm)

Video output

BNC (1Vpp, output impedance 75Ohm)

Audio output

Cinch (0.5Vpp, output impedance 1kOhm)

AUX.

Video output

BNC (1Vpp, output impedance 75Ohm)

Audio output

Cinch (0.5Vpp, output impedance 1kOhm)

System cable

4-wire dual twisted pair ‘telephone’ cable

Weight

12kg

Dimensions (hxwxd)

320x350x370mm.

Ambient temperature

Operating

+10...+45°C

Storage

-25...+70°C

Ambient humidity

93...98%RH max.

Specifications may change without notice.

122

Summary of Contents for VSS7370/00T

Page 1: ...operate observation and security system Operation and programming of the system is performed through On Screen Display OSD menus With these menus you can adapt the system to your own convenience If you follow the installation and operation instructions as described in the following sections you will quickly learn how to adjust and operate your observation system The following items are included in...

Page 2: ... Menu off This button selects the next camera input video image sound Menu on This button increases or changes the value of a selected menu item 7 Auto next N There are two possibilities Menu off This button switches the auto sequence function on off Remark Auto sequence is only functional when you have installed more than one camera Menu on This button selects the next menu item 8 View J Press th...

Page 3: ...e scanned again Therefore always switch off the system when a camera or accessory is added or removed Only operating the power save button is not sufficient Camera To ease the installation of the camera take it and the system monitor to the area you want to observe With the monitor on site you can check whether the camera covers the required area For the installation of the camera you should consu...

Page 4: ...n on the intercom box is pressed a buzzer sounds and the symbol u is visible at the upper left hand side of the monitor screen The monitor switches to the camera input the intercom box is designated to Remark The talk button and doorbell function are only functional in combination with an intercom box optional Action function Press I for instance to open a door As long as I is pressed a buzzer sou...

Page 5: ...s are lost Use the AUTO INSTALL function see Installation Menu to scan the system The system monitor will register the camera configuration again How do the menus work With the On Screen Display menus you can adjust various system control functions The following menus can be selected The menu control buttons The menus are operated with the following control buttons 1 M Switches the main menu on of...

Page 6: ...NT is highlighted Press K or L to deactivate OFF or activate ON the silent function 4 Alarm history list HISTORY When you select HISTORY a list with the date time kind of alarm and the camera input number of the last 9 alarm events is displayed Select HISTORY from the Main Menu Press N until the symbol Y next to HISTORY is highlighted Press K or L r The history list appears Press M when you want t...

Page 7: ...ll Menu Press N until the symbol Y next to AUTO INSTALL is highlighted Press K or L to start the installation procedure r The text SYSTEM CHECK appears on the monitor screen After approximately 20 seconds the following texts can appear on the monitor screen AUTO INSTALL COMPLETED r The system is installed correctly After approximately 30 seconds or when a button is pressed the Install Menu returns...

Page 8: ...n is pressed the message will disappear from the monitor screen Remark Although the cameras will work none of the accessories in any line will be functioning No valid camera input selection The camera number of an intercom box or Alarm Action box cannot be set to a camera input to which no camera is connected If the system monitor detects an invalid camera input selection it shows the following me...

Page 9: ...tector PIR Remark One camera line can contain up to two intercom boxes and two Alarm Action boxes with or without PIR Interface box By means of the interface box it is possible to add or extract standard video and audio signals from the system cable e g to connect third party cameras or a cash register interface Mains power adaptor If the camera cable is more than 200m 600ft this adaptor must be u...

Page 10: ...utput 1 system interface Microphone electret Frequence range 300 3kHz Alarm output 4 pole screwblock N O N C contact system ground Contact rating 24VDC 2A VCR Video input BNC 1Vpp input impedance 75Ohm Audio input Cinch 0 5Vpp input impedance 10kOhm Video output BNC 1Vpp output impedance 75Ohm Audio output Cinch 0 5Vpp output impedance 1kOhm AUX Video output BNC 1Vpp output impedance 75Ohm Audio o...

Reviews: