background image

9

Zoom During VCR Playback
To zoom a quadrant in the recorded VCR display on the
MON-A monitor, select that quadrant as the active
quadrant by using the arrow buttons. An asterisk (*) will
indicate the active quadrant. Press ZOOM to zoom that
quadrant to full screen display. Once in Zoom mode, the
arrow buttons will act as Pan and Tilt controls. Press
ZOOM or the QUAD button to return to normal VCR
playback.

The MON-B monitor will continue to display the full VCR
signal continuously. The dual VCR input displays give the
user maximum flexibility to examine VCR playback.

To exit VCR mode: Press VCR.

5.2.8

SEQ Button

Starts or stops sequencing on the MON-A quad displays for
the TC8278 Series only. For full screen sequencing, refer to
Monitor B operation.

Quad Page Sequencing (TC8278 Series Only)

In this mode, the SEQ button may be used to toggle the
sequencing of the two quad pages on and off.

To start sequencing of the two quad pages on the MON-A
output, press SEQ. This will cause a quad display of cameras
1 thru 4 to sequence with a quad display of cameras 5 thru
8, at the quad sequence dwell time.

Note that an active quadrant must not be selected at the
time that quad page sequencing is selected. If there is an
active quadrant displayed on the screen, first press QUAD
and then SEQ to start full quad sequencing.

The quad sequence dwell time is menu programmable
between 1 and 99 seconds.

To stop quad page sequencing, the operator can either press
SEQ or press QUAD. Note that pressing an arrow button
to select an active quadrant during full quad display
sequencing will allow an operator to stop (or re-start) the
sequencing of any one quadrant at a time, as explained
below.

If sequencing is in progress on either monitor, it will be
indicated on-screen on the corresponding monitor(s) by the
indicator "SEQ".

Individual Quadrant Sequencing 
(TC8278 Series Only)
The operator can also sequence individual quadrants while
other quadrants remain static. The MON-A monitor must
NOT be in full-screen display mode when starting
sequencing. The full-screen or zoomed displays on the quad
monitor cannot be sequenced.

To start sequencing of an individual quadrant which is not
already sequencing, first press any arrow button once to
initiate the active quadrant mode, then use the arrow
buttons to select the quadrant and press SEQ. This will
immediately start sequencing in the active quadrant, while
the status of the other quadrants will not be affected.

If sequencing is required in other individual quadrants, use
the arrow buttons to select a new active quadrant and
press SEQ. The active quadrant automatically times out in 5
seconds after there is no button activity, so when all
quadrants have been programmed there is no further action
required by the operator to exit the active quadrant mode.
Alternatively, pressing QUAD at any time will end the active
quadrant mode.

Quadrants will sequence between the two input cameras
related to the quadrant, namely 1 and 5, 2 and 6, 3 and 7,
and 4 and 8 respectively.

To stop sequencing of one individual quadrant, use the
arrow buttons to select the appropriate quadrant and press
SEQ.

To stop sequencing of all quadrants, press QUAD.This stops
sequencing and automatically selects the camera 1 thru 4
quad display.

Note that on the TC8278 Series, by starting and stopping
sequencing in individual quadrants, the user can get page
displays different to the standard pages of cameras 1 - 4, and
5 - 8. For example, camera 6 can be displayed along with
cameras 1, 3 and 4. To return to the standard quad pages of
1 - 4 and 5 - 8, press QUAD which selects the first quad
page of cameras 1 - 4, and then select sequencing or the
alternate page as desired.

If the MON-A monitor is in full-screen display mode, the
SEQ button will be ignored. Full screen displays on the
MON-A monitor cannot be sequenced.

5.2.9

FREEZE Button

Freezes or unfreezes all quadrants of the MON-A monitor
display.

Only images displayed on the MON-A monitor output can
be frozen. The FREEZE button has no effect on MON-B
monitor displays.

The FREEZE button is used both to freeze and to unfreeze
displays.

The operator can freeze any image on the MON-A monitor.
Full-screen displays, one quadrant of a quad display, or all
quadrants of a quad display can be frozen via a front panel
FREEZE button for further investigation of the image.

Note: FREEZE always stops any sequencing in the frozen
quadrant(s) of the image. Selecting alternative modes by
pressing SEQ, QUAD or ZOOM also unfreezes the display.

Freezing All  Quadrants
When no active quadrant is selected on the MON-A
monitor output, FREEZE will cause all 4 quadrants of the
present quad display to be frozen. If the FREEZE button is
pressed again, it will unfreeze all quadrants.

Freezing Individual Quadrants
If an active quadrant has been selected (refer to Arrow
Buttons), the FREEZE button will cause only the active
quadrant to be frozen or unfrozen.

Freezing a Full-screen or Zoomed Image
If a full-screen or zoomed image has been selected on the
MON-A monitor output, FREEZE will cause the MON-A
monitor display to be frozen. If the FREEZE button is
pressed again, it will unfreeze the display.

Unfreezing a Display
Besides using the FREEZE button as indicated above, any
frozen display will be automatically unfrozen when a mode
change is requested by using the QUAD, SEQ,VCR or
ZOOM buttons.

Summary of Contents for VidQuad Color Video Processors TC8278

Page 1: ...TC8275 Series TC8277 Series TC8278 Series VidQuad Color Video Processors Philips Communication Security Systems Instructions for Use ...

Page 2: ...objects of any kind into this unit through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the unit 16 Servicing Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 17 Da...

Page 3: ...tilisateur de la présence dans la documentation qui accompagne l appareil de consignes d utilisation et de maintenance importantes Attention L installation doit être effectuée uniquement par du personnel de service qualifié conformément à la réglementation du Code Electrique National ou à la réglementation locale Disjonction de l alimentation Les appareils avec ou sans commutateurs ON OFF sont ali...

Page 4: ...s El símbolo de exclamación dentro de un triángulo equilátero se muestra con el objetivo de alertar al ususario de que instrucciones de operación y mantenimiento importantes acompañan al equipo Atención La instalación de este equipo debe ser realizada por personal capacitado solo en acuerdo y en cumplimiento de normas del National Electric Code Código Eléctrico Nacional ó las normas del Gobierno N...

Page 5: ...screen text or status indications It has no alarm inputs or other status I O and there are no front panel controls The full featured four channel TC8277 Series and eight channel TC8278 Series have looping camera inputs and a VCR input plus two monitor outputs Both monitor outputs have switching capability and both include on screen text display capability for camera ID and titles date and time and...

Page 6: ...ny DIP switch adjustments These settings should only be performed by a qualified installer or service center See Location of DIP Switches under ILLUSTRATIONS 4 4 2 TC8277 Series Connect up to four cameras to the unit See Back Panel TC8277 Series under ILLUSTRATIONS There are two BNC connectors on the rear panel for each of the four camera inputs Use either one of these connectors as a camera input...

Page 7: ...operator The factory setting for the password is SELECT SELECT SELECT Note that the SELECT button is not normally a valid password button and cannot be used in a new password when it is set by the operator The only time that this button is used in the password is as a factory default on new units Buttons which are used in normal MENU operation the MENU SELECT and ARROW buttons are not valid as pas...

Page 8: ... to the whole page of the quad display Active Quadrant De selection The active quadrant display indication stays visible for approximately 5 seconds after the last keystroke after which it is automatically reset and the unit reverts to quad mode Pressing the QUAD button at any time will exit the active quadrant mode 5 2 5 ZOOM Button Operates only on the MON A monitor Used to switch from quad disp...

Page 9: ...ess SEQ The active quadrant automatically times out in 5 seconds after there is no button activity so when all quadrants have been programmed there is no further action required by the operator to exit the active quadrant mode Alternatively pressing QUAD at any time will end the active quadrant mode Quadrants will sequence between the two input cameras related to the quadrant namely 1 and 5 2 and ...

Page 10: ...rogrammable via the menu The sequence list can include any camera or the MON A display in the list several times and in random order To start stop sequencing on the MON B output select MON B followed by SEQ 5 3 Alarm Input Operation The product is equipped with 4 alarm inputs TC8277 Series or 8 alarm inputs TC8278 Series each associated with its corresponding video input System action during an ac...

Page 11: ...uence lists are not automatically changed as a result of video loss Cameras with video loss can still be selected for display on the MON B monitor screen which will be blanked while that video loss input is selected but will still display the camera title time date and other status text T e r m i n a t i o n S w i t c h e s O f f O n O f f O n S 2 S 1 M o s t c o m p o n e n t s r e m o v e d f o ...

Page 12: ...75 Series C a m e r a 1 C a m e r a 2 C a m e r a 3 C a m e r a 4 V i d e o 1 V i d e o 3 V i d e o 4 V i d e o 2 M a i n M o n i t o r S 9 4 0 4 0 0 3 A E C A M 1 C A M 2 C A M 3 C A M 4 Q U A D V I D E O O U T Typical Application TC8275 Series ...

Page 13: ...o r S w i t c h A d d i t i o n a l C a m e r a s C a m e r a 2 C a m e r a 3 1 6 11 2 7 12 3 8 13 4 9 14 5 10 15 S929A45AE Typical Application TC8278 Series Alarm Accessory Connector Pin Out Pin Function Pin Function Pin Function 1 Ground 6 Alarm 1 11 Alarm 2 2 Alarm 3 7 Alarm 4 12 Alarm 5 3 Alarm 6 8 Alarm 7 13 Alarm 8 4 Alarm Clear 9 Alarm Relay NO 14 Alarm Relay NC 5 No Connection 10 No Connec...

Page 14: ...A 3 C A M E R A 4 C A M E R A 5 S E L E C T T O S E L E C T S E Q U E N C I N G M E N U M O N B L I S T M O N B D W E L L Q U A D D W E L L E X I T S E L E C T T O S E L E C T M O N B S E Q L I S T 1 2 3 4 5 6 7 8 Q S E L E C T C A M E R A M O V E C U R S O R S E L E C T T O E X I T M O N B S E Q D W E L L T I M E 0 0 5 S E C O N D S C H A N G E N U M B E R S E L E C T T O E X I T T I M E 0 0 5 S ...

Page 15: ...15 Notes ...

Page 16: ...8 42 1998 Philips Electronics N V Printed In U S A 1998 Philips Communication Security Systems Inc All Rights Reserved Philips is a registered trademark of Philips Electronics N V Data subject to change without notice ...

Reviews: