13 December 2012
11
Power and Data Cabling Requirements
Power
The luminaire requires standard AC power distribution from 200-240 VAC, 50/60 Hz. Current
required is up to 12 Amps depending on the AC supply voltage and product model.
Note:
The mating Neutrik PowerCon connector is supplied, however, you will need to purchase or
construct a cable appropriate for your application.
Figure 2-1: Power Connector
Depending on the application, the luminaire’s AC input cable may require a different connector. If
required, install a new connector meeting your requirements using the following wire color code
reference:
WARNING:
DO NOT connect to three-phase Delta service in countries with 240 volt power.
Note:
The lamp will not strike below 180 volts RMS.
Neutrik PowerCon
Connector (supplied)
ENTER
MENU
DATA THRU
DATA IN
~
AC IN
AC Power Input
3-Pole Neutrik PowerCon
Locking Connector for AC
Input Power
Luminaire Enclosure Assembly
Wire*
Connection
Green/Yellow
AC Ground
Blue
AC Neutral
Brown
AC Line
* International (Harmonized) Standard