Connecting Data and Power
A maximum of 32 luminaires may be connected in any one DMX data link.
Note:
This maximum limit applies to the luminaire "daisy chain" only. Your system or console may
require fewer luminaires on a single data link path. Consult your console documentation for more
information.
To connect power and data:
Step
1. Connect data cable from console to first luminaire in chain at DATA IN connector.
Step
2. If required, connect additional data cables from DATA THRU connectors to DATA IN
connectors of remaining luminaires in link.
Step
3. At last luminaire in link, install male termination connector at DATA THRU connector.
(Luminaires and other devices on the same DMX chain may not function properly without
termination.)
Figure 2-11: Data Link
Step
4. Connect AC Input Cable connector to power input source.
Step
5. Dress AC input and data cables and secure them so that they will not interfere with
luminaire head and yoke movement.
Data In
Termination
Data Thru
AC In
AC In
AC In
VL440 / VL770 / VL880 Luminaire Channel Requirements
Model
DMX512 Channels
VL440 Spot
30 Channels
VL770 Spot
30 Channels
VL880 Spot
30 Channels
Data Thru
Summary of Contents for VARI-LITE 400 Series
Page 1: ......
Page 13: ...FOREWORD 02 9687 0001 0 26 July 2011 xi ...
Page 14: ...VARI LITE VL440 VL770 VL880 LUMINAIRE USER S MANUAL xii 26 July 2011 02 9687 0001 0 ...
Page 18: ...VARI LITE VL440 VL770 VL880 LUMINAIRE USER S MANUAL 4 26 July 2011 02 9687 0001 0 Notes ...
Page 22: ...VARI LITE VL440 VL770 VL880 LUMINAIRE USER S MANUAL 4 26 July 2011 02 9687 0001 0 Notes ...
Page 80: ...VARI LITE VL440 VL770 VL880 LUMINAIRE USER S MANUAL 62 26 July 2011 02 9687 0001 0 Notes ...
Page 115: ......