background image

1. 

Products are not intended and shall not be used in applications or activities which may cause death, personal injury and/or d amage 

to the environment 

 

2. 

Products not designed and/or intended to be used to disinfect medical devices or for medical purposes; Signify excludes any a nd all 

liability for any such improper use.

3. The UV-C of this product is much stronger than normal sunlight. If you're exposed to UV-C light, it will cause a severe sunburn on 
your skin, which can also damage your retina.
4. 

Plants and/or materials that are exposed to UV-C and/or ozone for a long time may become damaged and/or discolored.

5. Do not put valuables, such as calligraphy and painting, antiques, etc. into the disinfection chamber for disinfection. Signify is not 
responsible for any related damages.
6. Children shall be supervised to ensure that they do not play with the appliance. And do not put people, animals or plants in  the 
chamber.
7. To avoid accidental start of UVC lamps, do not carry magnetics close to the control panel when power is on.
8. Please make sure the glass door is fully closed before start the disinfection.
9. Hard objects are prohibited to collide with the UV lamp tube and its shade.
10. If the UV lamp is damaged, it must be replaced with the Philips lamp tube.(TUV PL-L 18W/4P).
11. Please use the socket with rated current above 5A and with reliable grounding wire.
12. The power cord is Y-type connection. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 
similarly qualified persons in order to avoid a hazard.
13. If it is found that the light emitted by the ultraviolet light tube can be seen directly through without any object (such as glass 
brocken, etc.), the operation shall be stopped immediately and inform professional maintenance service.
14. If it is found that abnormal smell, high temperature on the housing, noise and smoke), plug must be disconnected and inform 
professional maintenance service.
15. Do not disassemble and repair without permission. It must be repaired by the manufacturer or its maintenance department and 
other similar professionals.
16. Do not immerse the disinfection chamber in water or spray water on it.
17. Objects shall be placed on the tray when doing disinfection.
18. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack 
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person 
responsible for their safety.

 Do not spray water on the chamber.

 Do not let water in the vicinity of lamp holder.

 Power off during maintenance or cleaning.

 When maintenance or cleaning, open the door completely, then take out the shelf.

 External: the chamber can be cleaned with a wet towel. Strong solvents or detergents are not recommended.  But neutral mild 

cleaners are recommended

no residual cleaners after cleaning.

 Interior: clean the interior walls with ethanol (reagent grade) and soft towel to avoid scratching the surface. Be careful not to spray 

or apply chemicals directly on the UV lamp tube. This may damage the product.

 Please maintain in strict accordance with the above requirements.  

   

. Maintenance

  

. Troubleshooting

Note: UV lamp and ballast shall be handled according to local laws and regulations. For more information, please visit Signif y 

website

https://www.lighting.philips.com/main/products/uv-disinfection/object

Fault Phenomenon

Possible Causes

Processing Method

Bad contact between plug and socket

Plug in again

Fuse blow

Change the fuse

Power cord was broken

Change the power cord

No electricity in the socket

Check the power supply line

The door is not closed

Close the door 

The internal components of UVC chamber are 
damaged

Contact dealer

The lamp tube is damaged

Contact dealer

The PCB borad is damaged

Contact dealer

Internal wiring problem

Contact dealer

The ballast is damaged

Contact dealer

May have protective oil smell for the first use

Clean the cavity

The Chamber is not clean

Clean the chamber

The disinfection chamber emits smoke or 
burning smell

The internal components of chamber are damaged

Contact dealer

UVC lamp tube aged

Change the lamp tube correctly 
according to the manual

Incorrect operation

Follow the instructions correctly

UVC chamber does not work

UVC lamp not work

Peculiar smell in the disinfection chamber 

Failed to pass UV dose verification