Mechanical Instructions
4.
Disassembly Slave Inverter
1.
Place the panel face down on the foam bars, and locate the
Inverter board.
2.
Remove the cover screws, and remove the cover.
Figure 4-70 Remove Inverter cover screws
3.
Unplug the lamp connector on the inverter. Be careful not
to pull and drag the wires. The use of a pair of pliers can be
helpful.
Figure 4-71 Remove Inverter connectors
4.
Unplug connector on the Inverter board (see figure below),
and remove the inverter panel.
Figure 4-72 Remove connector
Reassembly Slave Inverter
To reassemble, perform all processes in reverse order.
H_16901_021.ep
s
171007
H_16901_022.ep
s
171007
H_16901_02
3
.ep
s
171007