WING WHITE LED WALL WASHER Operation Manual
Version 1: June 2011 ©2011 Philips Selecon All Rights Reserved
7of13
Installation
Electrical Installation
WARNING!!!
Risk of fire and electric shock. This product is to be installed by a qualified electrician only. Ensure
that the AC power is switched off before attempting to make any wiring connections.
This fixture employs a grounded type receptacle and is not intended for connection to a two-wire, ungrounded
source of supply.
To avoid the chance of product damage or malfunction, disconnect power before connecting wires, and do not
connect or disconnect cables (supply, data, lamps and interface cables) when voltage is supplied to the luminaire.
Mains Voltage:
120-277VAC. (unit must be direct switching mains only, not via a dimmer system).
When installing this fixture use wire conductor colour codes as follows:
Brown
- Phase, live
Blue
- Neutral, return
Green
/
Yellow
- Earth
Notes
:
1. For ceiling rose models – minimum 60°C supply conductors to be used.
2. Track adapter variants are only to be fitted to approved and compatible track systems.
Wing LED Applications
The Wing range has been designed to meet demanding quality light level applications such as museums and
galleries – multiple units are required to obtain a visually even wash of light.
Recommended spacing of luminaires is to have the luminaires at equal spacing to the distance from the wall. For
example if the luminaires are 1.5m away from the wall the optimum spacing between the luminaires for an even
wash of light would also be 1.5m.
For optimum light distribution the Wing has been designed to be installed
at a 45deg nominal angle as indicated.
Ambient Operating Temperature:
-10°C to 40°C
To guarantee product lifetime, the user should ensure that the ambient temperature remains within the
recommended temperature range.
The Wing White LED Wall Washer is a high power LED product with high optical output. Operators of the LED
modules should not look directly into the beam of the light source (especially not with magnifiers or similar optical
instruments) as this may cause damage to the eyes.
Further information relating to the lux levels, luminaire spacings and IES/ILUMUDAT files can be found at
www.seleconlight.com/ies
and
www.seleconlight.com/ilumudat