Baby unit

Connect the AC power adapter (A-9) to an AC mains socket, and then connect the cord to the DC
power supply socket (A-5) of the Baby unit.

If you want to use batteries, remove the battery compartment cover (A-7) using a screwdriver. Insert
four 1.5V, AA batteries (not included; we recommend non-chargeable Philips Alkaline batteries), noting
the + and - configuration inside the battery compartment. Put the cover back in place and tighten screw.

The Baby unit operates cordlessly for up to 30 hours on fresh batteries. The red 

POWER 

light (A-2)

flashes when battery power is low. If this happens install new batteries.

Note

: To switch off the Baby unit completely push the 

POWER 

button (A-4) .

Small Parent unit

The small Parent unit uses a rechargeable battery pack. This is already installed, but first it must be
charged for at least 14 hours as follows before using the unit outside the charging base:
• Connect the AC power adapter (B-11) to an AC mains socket, and then connect the cord to the DC

power supply socket (B-10) of the charging base (B-6).

• Place the small Parent unit inside the charging base. The red charging light (B-13) lights.

The small Parent unit can be operated now but you should leave it in the charging base until the
batteries are fully charged (at least 14 hours). When the batteries are fully charged, take the small Parent
unit out of the charging base and use cordlessly for up to 12 hours.

When the red 

POWER 

light (B-2) on the small Parent unit flashes, the battery power is low. Place the

small Parent unit inside the charging base to recharge the batteries.

Big Parent unit

Connect the AC power adapter (C-9) to an AC mains socket, and then connect the cord to the DC
power supply socket (C-8) of the big parent unit.

If you want to use batteries, remove the battery compartment cover (C-6) using a screwdriver. Insert
four 1.5V, AA batteries (not included; we recommend non-chargeable Philips Alkaline batteries), noting
the + and - configuration inside the battery compartment. Put the cover back in place and tighten screw.

The big Parent unit operates cordlessly for up to 30 hours on fresh batteries. The red 

POWER 

light (C-1)

flashes when battery power is low. If this happens install new batteries.

8

Problem

Possible Cause

Solution

Unit is not turned on.

Batteries are low.

Unit is not turned on.

AC adapter is not plugged in or
Batteries are exhausted.

AC adapter plugged into an
outlet that is not working.

Units are too close together.

Volume too high.

Battery life is at an end.

Volume control on Parent unit is
set too low.

Units are out of range.

Batteries are low or empty.

Mobile or cordless phones too
close to the baby monitor can
cause interference.

Both systems are using the same
frequencies

Units are out of range or there is
interference from another FM
source

Turn Volume control/Off switch
clockwise (B-4, C-4).

Recharge batteries.

Push the 

Power 

switch (A-4) to

switch on the unit.
Plug in AC adapter or replace
batteries.

If the power socket has a switch,
turn it on.

Move Parent unit away from
Baby unit.
Turn volume control on Parent
unit counter-clockwise.

Replace rechargeable battery
pack.

Turn volume control/Off switch
clockwise (B-4, C-4).

Move Parent unit closer to Baby
unit.

Parent unit:- recharge batteries.
Baby unit:- replace batteries or
connect to mains power.

Move the phones away from the
units.

Switch channels.

Move parent units closer to baby
unit to restore the link. Remove
the other FM source.

Power 

light does not light

(Parent unit).

Power 

light does not light

(Baby unit).

High pitched noise.

Parent unit batteries do not
charge.

No sound.

Power 

light blinking.

Interference or poor
reception.

Receiving signals from a
different baby monitor.

System check light flashing/
system check alarm activated

P

ROBLEM

 

SOLVING

IFUSC369ENbk.p65

14/10/2002, 11:29

5

Summary of Contents for SBC SC369/05

Page 1: ...tekening v d handelaar Forhandlerens navn adresse og unterskrift Nombre direccion y firma del distribudor Jälleenmyyjän nimi osoite ja allekirjoitus Nome indirizzo e firma del fornitore Nome morada e assinature da loja 0682 month guarantee on rechargeable batteries mois de garantie sur les piles rechargeables meses de garantía para las pilas recargables Monate Garantie auf wiederaufladbare Batteri...

Page 2: ...A C H A N N E L B POWER POWER TRANSMIT MIC A 1 2 3 4 7 5 6 B 8 11 369ENbk p65 14 10 2002 11 29 2 A CHANNEL B DC 9V LINK POWER CHARGE CHARGE 1 2 8 7 4 5 6 9 13 12 11 10 LINK POWER 28 07 2003 17 13 Pagina 2 ...

Page 3: ... in touch with each other B 2 Power light lights when unit is powered flashes when batteries are low B 4 Loudspeaker provides clear sound B 5 Loudspeaker Volume control Off switch set loudspeaker level switches off the power to the unit completely B 6 Charging base place unit in base to operate it on mains power and when batteries are low B 7 Belt clip handy clip for carrying the unit B 8 Channel ...

Page 4: ... on the Parent and Baby units are fixed do not try to extend them Never cover the Baby unit with a towel blanket etc 9 TECHNICAL SPECIFICATIONS Power supply Battery pack rechargeable NiMH for small Parent Unit included Optional batteries 4 x 1 5V AA alkaline for Baby Unit and big Parent unit not included AC power adapter 230V AC 50 Hz three included Output voltage 9V DC 200mA Only use the AC power...

Page 5: ...e battery compartment cover C 6 using a screwdriver Insert four 1 5V AA batteries not included we recommend non chargeable Philips Alkaline batteries noting the and configuration inside the battery compartment Put the cover back in place and tighten screw The big Parent unit operates cordlessly for up to 30 hours on fresh batteries The red POWER light C 1 flashes when battery power is low If this ...

Page 6: ...y unit are in touch with each other This light flashes if the Baby unit is out of range for more than 30 seconds or if the signal is blocked When the units are no longer in touch try one of the following Move the Parent unit closer to the Baby unit The maximum operating distance is 200m in ideal conditions Walls and floors can limit this distance Switch all units to the other channel Check that th...

Reviews: