background image

1

Instructions for Use

Wisp Nasal Mask

Intended Use

The Wisp Youth Nasal Mask is intended to provide an interface for application of CPAP or bi-level 

therapy to patients. The mask is for single patient use in the home or multi-patient use in the hospital/

institutional environment. The mask is to be used on patients 7 years or older (>40 lbs/18kg) for whom 

CPAP or bi-level therapy has been prescribed.

The Wisp Nasal Mask is intended to provide an interface for application of CPAP or bi-level therapy to 

patients. The mask is for single patient use in the home or multi-patient use in the hospital/institutional 

environment. The mask is to be used on patients (>66lbs/30kg) for whom CPAP or bi-level therapy has 

been prescribed.

 

Notes:

 

Exhalation is built into this mask so a separate exhalation device is not required. 

 

This mask is not made with natural rubber latex or DEHP. 

 

Caution: 

U.S. Federal law restricts this device to sale by or on the order of a physician.

Symbols

Warning or Caution

Note

 Tip

Not Made with Natural Rubber Latex

X1

System One Resistance Control

 Warnings

 

This mask is not suitable for providing life support ventilation.

 

Hand wash prior to use. Inspect the mask for damage or wear (cracking, crazing, tears, etc). Discard and 

replace any components as necessary.

 

Some users may experience skin redness, irritation, or discomfort. If this happens, discontinue use and 

contact your healthcare professional.

 

Consult a physician or dentist if you encounter tooth, gum, or jaw soreness.  Use of a mask may 

aggravate an existing dental condition.

 

Consult a physician if you experience the following symptoms while using the mask or after removing 

it: Drying of the eyes, eye pain, eye infections, or blurred vision. Consult an ophthalmologist if 

symptoms persist.

 

The mask material should be away from your eyes.

 

Do not block or seal off the exhalation ports.

 

Do not overtighten the headgear straps. Watch for signs of overtightening, such as excessive 

redness, sores, or bulging skin around the edges of the mask. Loosen the headgear straps to alleviate 

symptoms.

 

This mask is designed for use with CPAP or bi-level systems recommended by your health care 

professional or respiratory therapist. Do not wear this mask unless the CPAP or bi-level system is 

turned on and operating properly. Do not block or try to seal the exhalation port. 

Explanation of 

the Warning:

 

CPAP systems are intended to be used with special masks with connectors which have 

vent holes to allow continuous flow of air out of the mask. When the CPAP machine is turned on and 

functioning properly, new air from the CPAP machine flushes the exhaled air out through the attached 

Summary of Contents for Respironics Wisp Youth

Page 1: ...tears etc Discard and replace any components as necessary Some users may experience skin redness irritation or discomfort If this happens discontinue use and contact your healthcare professional Consult a physician or dentist if you encounter tooth gum or jaw soreness Use of a mask may aggravate an existing dental condition Consult a physician if you experience the following symptoms while using t...

Page 2: ...re At a fixed flow rate of supplemental oxygen flow the inhaled oxygen concentration will vary depending on the pressure settings patient breathing pattern mask selection and the leak rate This warning applies to most types of CPAP and bi level machines At low CPAP or EPAP pressures the flow through the exhalation port may be inadequate to clear all exhaled gas from the tubing Some rebreathing may...

Page 3: ...ions Do not clean the mask with bleach alcohol solutions containing bleach or alcohol or solutions containing conditioners or moisturizers Inspect the mask for damage or wear cracking crazing tears etc Discard and replace any components as necessary Any deviation from these instructions will impact the performance of the product Institutional Disinfection For multi patient use in the hospital inst...

Page 4: ... Adjust side straps evenly f 8 Headgear Adjust bottom straps evenly g The mask should rest comfortably against face h Note Do not overtighten the headgear Using Tube Management Optional The flexible tubing may be placed over head 9 Slide the mask tubing through the headgear crown loop i before attaching the flexible tubing Using the Mask 10 Connect the flexible tubing included with the CPAP or bi ...

Page 5: ... the cushion will match the alignment cutouts of mask frame m Attaching the Elbow and Tubing Push the elbow into the cushion until the Quick Release Tabs click into place k Attaching the Headgear 1 Hold the crown strap upward 2 Make sure the wide strap marked with Philips Respironics is outward 3 Slide the headgear tabs into the longer frame arm slots 4 Connect the headgear clips to the frame or s...

Page 6: ...hieved and leak or variation in the rate of leak may affect device function Pressure Flow Curve 0 10 20 30 40 50 60 0 5 10 15 20 25 30 Flow Rate SLPM Pressure cm H2O Resistance Drop in Pressure at 50 SLPM 100 SLPM All sizes 0 8 cm H2 O 3 2 cm H2 O Deadspace Volume P 37 mL S M 49 mL L 73 mL XL adult only 85 mL Sound Levels A weighted Sound Power Level 27 dBA A weighted Sound Pressure Level at 1 m 1...

Page 7: ...ING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS SPECIFICALLY DISCLAIMED SOME STATES DO NOT ALLOW DISCLAIMERS OF IMPLIED WARRANTIES SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE To exercise your rights under this limited warranty contact your local authorized Res...

Page 8: ...on Explication de l avertissement Les systèmes de PPC sont prévus pour être utilisés avec des masques spéciaux dont les connecteurs sont équipés d orifices d évacuation autorisant un flux d air continu sortant du masque Lorsque l appareil de PPC est activé et fonctionne correctement l air frais qu il envoie chasse l air expiré à travers la valve d expiration intégrée au masque Toutefois lorsque l ...

Page 9: ...isation Lavez l intégralité du masque à la main a Lavez le visage N enduisez pas vos mains ou votre visage de lotion ou de crème hydratante Procédez à une inspection du masque Remplacez le coussinet s il a durci ou s il s est déchiré Remplacez les pièces endommagées ou usées Instructions de nettoyage Au quotidien lavez à la main les pièces non textiles Toutes les semaines lavez à la main les pièce...

Page 10: ...ort aisé et confortable Avant de mettre le masque 1 Choix de la taille Sélectionnez le coussinet adapté à la largeur de votre nez sans bloquer les narines Le haut du coussinet doit se trouver entre l arête et le bout de votre nez Positionnement du masque 2 Languette ou clip du harnais Débranchez en un ou les deux b Tirez sur les languettes du harnais en les éloignant des sangles puis tirez à trave...

Page 11: ...du masque 10 Fixez le tube flexible inclus avec votre appareil de PPC ou à deux niveaux au raccord 11 Mettez l appareil de thérapie sous tension Allongez vous Respirez normalement 12 Essayez différentes positions pour dormir Trouvez la position la plus confortable En cas de fuites d air excessives procédez à des réglages supplémentaires La présence de petites fuites est normale Conseils de confort...

Page 12: ...rs l extérieur 3 Faites glisser les languettes du harnais dans les fentes du bras de coque le plus long 4 Accrochez les clips du harnais sur la coque ou faites glisser les languettes dans les fentes pour les bras de la plus petite coque si vous n utilisez pas les clips du harnais Contrôle de résistance Philips Respironics System One Lorsqu il est utilisé conjointement à un appareil Philips Respiro...

Page 13: ... l espace mort P 37 ml S M 49 ml L 73 ml XL uniquement pour adultes 85 ml Niveau sonore Niveau de puissance acoustique pondérée A 27 dBA Niveau de pression acoustique pondérée A à 1 m 19 dBA Mise au rebut Éliminez ce produit conformément aux réglementations locales Conditions d entreposage Température 20 C à 60 C 4 à 140 F Humidité relative 15 à 95 sans condensation Pression cm H2 O Débit SLPM ...

Page 14: ...t été réparé ou modifié par quiconque ne faisant pas partie du personnel de Respironics Respironics ne peut pas être tenue pour responsable des pertes économiques pertes de bénéfices coûts directs ou indirects et autres dommages consécutifs spéciaux ou accidentels susceptibles de résulter de la vente ou de l utilisation du Produit La limitation ou l exclusion de certains dommages accessoires ou co...

Page 15: ...15 ...

Page 16: ...16 1098148 R07 LZ 04 07 2015 2015 Koninklijke Philips N V All rights reserved Respironics Inc 1001 Murry Ridge Lane Murrysville PA 15668 USA ...

Reviews: