REPAIR INSTRUCTIONS                                                                                                               

GC8651 

 

Due to the high wattage of the iron, only the specified cord set must be used. 

 Should damage be observed on the HOSE-CORD ASSY or CORDSET 

14

, they must be replaced. 

Continued usage is not allowed. 

 When replacing the MICROSWITCH ASSY 

4

, please dress the 2 attached wires such that they are free of tension. 

Pulling force on the wires may affect the steam triggering. 

 To avoid damage to the sealing & components of the BOILER ASSY

 33

NEVER clean the boiler assy with vinegar, 

descaling agent or other corrosive chemicals. 

 When replacing ELECTROVALVE

 28

 or PUMP ASSY 

39

, please be reminded to apply loctite at the joints for good 

sealing. 

 After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations 

as laid down & officially established at this moment. 

 The following tests are common checks that are conducted on a repaired product before it is returned to the consumer. 

1. Soleplate temperature 

Check that soleplate temperature is within IEC requirement. 

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 

15 minutes. The table below shows the temperature requirement. 

 

2. Leakage current 

Check that leakage current is within IEC requirement. 

Measure leakage current between LIVE/NEUTRAL & EARTH. 

IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA. 

3. Water leakage / Functionality 

Check that there is no water leakage from any part of the product during operation. 

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working 

properly. 

4. Loose part 

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction. 

 

 

Summary of Contents for PerfectCare Aqua GC8651

Page 1: ...TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power 2400 W Dimension F box 362 D x 270 W x 263 H mm Weight of iron 1 kg Weight of iron base 4 5 kg Water Advice Suitable for tap water use Advice to mix with equal portion of distilled water or use only distilled water if the tap water is very hard Soleplate Steam Glide New SteamGlide soleplate is the best Philips soleplate It has great ...

Page 2: ...7 Disassemble Plastic washer 1x 8 Remove Screw E1 E2 Remove F Disassemble Decoration cap printed 9 Ryton ring 10 Deviator housing molded 11 Iron thermistor assy 12 Plstic washer 2x 8 Rear Hose cord mounted assy 14 Housing printed 15 Soleplate mounted assy 16 Remove Screw A Disassemble Light strip 1 Remove Screw B Disassemble Inlay and light strip assy 2 Disassemble Reflector molded 3 Remove Screw ...

Page 3: ... LED microswitch holder assy 5 423901454961 Trigger spring 6 423902649752 Trigger molded 7 423901012911 Mica plate 8 423902649501 Plastic washer 9 423902170741 Decoration cap printed 10 423901570153 Ryton ring 11 423902649491 Deviator housing molded 12 423902169942 Iron thermistor assy 14 423902170703 Hose cord mounted assy 15 423902170692 Housing printed 16 423902170651 Soleplate mounted assy ...

Page 4: ...EXPLODED VIEW IRON GC8651 ...

Page 5: ...Water tank assy 23 Remove Safety cap 25 Release Inox clamp 26 2x Disassemble Braided rubber hose Boiler 27 Release Hose clip Disconnect Wires Disassemble Electrovalve 28 Remove Screw O1 O2 P Remove Spacer top 29 Remove Screw Q Disassemble Rinse housing cap printed 30 Remove Screw R Disassemble Rinse housing molded 31 Disassemble O ring 32 Disassemble Boiler assy 33 Disassemble Boiler support brack...

Page 6: ...01010261 Inox clamp 27 423901559771 Braided rubber hose Boiler 28 423901712802 Electrovalve 29 423902651241 Spacer top 30 423902172612 Rinse housing cap printed 31 423902649732 Rinse housing molded 32 423901559751 O ring 33 423902169891 Boiler assy 34 423902642581 Boiler support bracket 35 423902632181 Spacer bottom 36 423902169951 Boiler thermistor assy 37 423902170772 Power button printed 38 423...

Page 7: ...EXPLODED VIEW STAND GC8651 L2 ...

Page 8: ...WIRING DIAGRAM GC8651 ...

Page 9: ...ally established at this moment The following tests are common checks that are conducted on a repaired product before it is returned to the consumer 1 Soleplate temperature Check that soleplate temperature is within IEC requirement Measure the temperature of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperatur...

Reviews: