1.15
Signal format is as follows:
1
Data Format:
1,200 Baud / 8 Data Bit / No Parity / One
Stop Bit
2
Mode:
Half Duplex Mode (The unit is not Echo Received
Character.)
Table - (RS-232 Commands)
COMMAND
RS-232 CODE
VCR input
/VR
Enter the programming mode
/ME
Sequence/Reset
/SR
Camera 1/Up
/1U
Camera 2/Down
/2D
Camera 3/Left
/3L
Camera 4/Right
/4R
Quad display/Enter
/QE
6.2.10
Factory Default Settings
You can restore the unit to its factory default settings as follows:
n
Press and hold the
VCR
key and plug the power cord (turn
on power). This restores the unit to its initial values.
The initial Factory Defaults values are as follows:
n
CAMERA TITLES;
Display as "
1
", "
2
", "
3
", "
4
".
n
VCR OUT MODE;
It set up as "
Display Quad Only
"
Mode.
n
ALARM SETUP;
Alarm Channels are all
ON
, and Video
Loss Channels are all
OFF
. Dwell Time is set up as
5 sec
.
n
SEQ SETUP;
Each
2 seconds
(1~4 and Quad).
n
TIME/DATE;
Time and Date are not changed, Format is
set up as
MM/DD/YEAR.
n
PASSWORD SET;
Password is
disabled
.
7.
MAINTENANCE
The Quad unit requires no routine maintenance and is
designed for long, trouble-free use under normal
operating conditions. Repair should only be attempted
by qualified personnel.