Please take note of the following points when performing the Database Scanning function:
1.
The remote will NOT exit the Database Scanning mode, except for the following occurrence:
1. If no key selected within 30 seconds.
2. If stuck key timed out (not applicable for pressing “UP” key).
3. If “BACK” key is pressed.
4. If “LEFT” key is pressed after the 1st codeset in the search had last transmitted.
5. If “RIGHT” key is pressed after the last codeset in the search had last transmitted.
2.
If failed to program codeset in Step 7, the previous programmed codeset (if any) will be
retained.
3.
If the PowerToggle IR command for all codesets in the list is transmitted in Step 3, the TV
POWER LED will give 10 fast blinks to indicate “End-Of-Search”.
4.
When database scanning is in progress, RF functions are disabled (e.g. keys on KEYBOARD
side are locked). Only after exiting from Database Programming mode, the RF functions are
resumed.
5
The learn codes or default IR codes (RC6 Mode 6A) underlying each of IR keys will be replaced
with the IR codes from the valid codeset ID being programmed into the RC.
4.4 Infrared (IR) Factory Reset
The user is able to reset all the IR keys back to factory default settings. These keys will transmit the
default IR code (RC6 Mode 6A).
This is done by pressing the “MUTE” key and “AV” key simultaneously for 3 seconds. SYSTEM
POWER key will turn ON and user has to release all keys. The RC starts erasing all learned data and
programmed codeset ID and returns to its original settings; i.e. before any learning or autosearch was
performed. Upon successful erasure, SYSTEM POWER LED will give 2 slow blinks, otherwise 3 fast
blinks to indicate failure.