![Philips IRT 9090 User Manual Download Page 19](http://html.mh-extra.com/html/philips/irt-9090/irt-9090_user-manual_317745019.webp)
SpaceWise for Industrial Applications
v. 1.6
Philips Lighting North America
18
9.
Activate / Deactivate occupancy sensor
Occupancy sensor is active by default. Changes have to be performed on each
luminaire in the group.
a.
Point remote to any luminaire and press
“unlock,” once.
Wait for LED to stop blinking (apx. 10
seconds).
Point remote to any of the luminaires
and press “send.”
Red LED on remote will start
blinking.
Red LED on remote will stop
blinking.
The luminaire will FLASH twice
and group light level will go to
50%.
b.
Press “pir” button.
While the LED is still blinking red, enter
the numbers:
“10”: Enable occupancy sensing
“12”: Disable occupancy sensing (lights
will stay at 100%)
Red LED on remote will start
blinking.
Red LED on remote will stop
blinking.