background image

iColor Flex LMX gen2

Flexible strands of high-intensity LED nodes with intelligent color light

Summary of Contents for iColor Flex LMX gen2

Page 1: ...iColor Flex LMX gen2 Flexible strands of high intensity LED nodes with intelligent color light ...

Page 2: ...lies Optional mounting tracks ensure straight linear runs while snap on spacers hide cabling and mounting hardware between nodes for a clean finished look Single node mounts can be positioned individually to provide anchor points for installations with uneven node spacing or complex geometries Optional glare shields can block unwanted spill light or prevent light sources from being visible in cert...

Page 3: ...ion with iColor Flex LMX now specified as iColor Flex LMX gen2 strands of flexible high intensity full color LED nodes designed for extraordinary effects and expansive installations Mounting tracks were used to secure 812 50 node iColor Flex LMX strands to the building s façade The strands were placed 300 mm 11 8 in apart vertically and 1 5 m 4 9 ft apart horizontally The result is surreal and stu...

Page 4: ... polycarbonate Translucent UV protected polycarbonate Luminaire Connections Integrated watertight 3 pin connector Temperature Ranges 40 to 50 C 40 to 122 F Operating 20 to 50 C 4 to 122 F Startup 40 to 80 C 40 to 176 F Storage 0 C 32 F Handling Humidity 0 to 95 non condensing Maximum Luminaires Per Power Data Supply PDS 60ca 24V 1 strand sPDS 480ca 24V 8 strands sPDS 60ca 24V 1 strand CM 150 CA 1 ...

Page 5: ...7 mm 0 66 in Ø 18 mm 0 71 in Clear Flat Lens 7 9 mm 0 31 in 31 76 mm 1 25 in 31 45 mm 1 24 in 18 mm 0 71 in 16 2 mm 0 64 in 16 7 mm 0 66 in 28 17 mm 1 11 in Ø 18 mm 0 71 in Ø 14 47 mm 0 57 in Translucent Dome Lens 7 9 mm 0 31 in 31 76 mm 1 25 in 31 45 mm 1 24 in 18 mm 0 71 in 16 2 mm 0 64 in 16 7 mm 0 66 in 26 99 mm 1 06 in Ø 18 mm 0 71 in Narrow Beam Lens ...

Page 6: ... 3 mm 2 53 in 1219 2 mm 4 ft 48 3 mm 1 9 in 45 mm 1 77 in 34 79 mm 1 37 in 34 5 mm 1 36 in 45 mm 1 77 in 8 5 mm 0 33 in 19 5 mm 77 in 52 mm 2 05 in Ø 26 mm 1 2 in 51 65 mm 2 03 in Marquee Bulb Base marquee bulb Mounting Track marquee bulb 27 07 mm 1 07 in 45 mm 1 7 in 8 33 mm 0 33 in 19 33 mm 0 76 in 45 mm 1 7 in 35 13 mm 1 38 in 35 18 mm 1 38 in 44 88 mm 1 77 in 14 92 mm 0 59 in 4 mm 0 16 in Glar...

Page 7: ...28 26 Coefficients Of Utilization Zonal Cavity Method ZONE LUMENS FIXT 0 30 8 6 29 2 0 40 14 1 47 9 0 60 24 2 81 9 0 90 28 0 94 8 90 180 1 6 5 2 0 180 29 5 100 0 Zonal Lumen iColor Flex LMX gen2 Translucent Dome Lens Center Beam fc Beam Width 4 ft 8 ft 12 ft 16 ft 20 ft 24 ft 0 fc 0 fc 0 fc 0 fc 0 fc 0 fc 62 9 ft 125 7 ft 188 6 ft 251 5 ft 314 3 ft 377 2 ft 80 6 ft 161 2 ft 241 9 ft 322 5 ft 403 1...

Page 8: ...0 98 0 96 0 96 0 94 0 92 0 92 0 91 0 89 0 87 1 04 0 98 0 92 0 88 1 01 0 96 0 91 0 79 0 92 0 88 0 85 0 88 0 85 0 82 0 85 0 82 0 80 0 78 0 97 0 89 0 83 0 78 0 95 0 87 0 82 0 72 0 84 0 79 0 76 0 81 0 77 0 74 0 79 0 75 0 72 0 71 0 91 0 82 0 75 0 70 0 89 0 80 0 74 0 65 0 78 0 72 0 68 0 75 0 71 0 67 0 73 0 69 0 66 0 64 0 86 0 76 0 69 0 63 0 84 0 74 0 68 0 60 0 72 0 67 0 62 0 70 0 65 0 61 0 68 0 64 0 60 ...

Page 9: ...et UK Cord 109 000021 05 912400133636 sPDS 480ca 24V Power Data Supply Ethernet 109 000026 01 912400133528 CM 150 CA 24V Power Data Supply DMX Ethernet 4 Wire DIN Rail Mount 109 000033 00 912400135766 DMX Ethernet 3 Wire DIN Rail Mount 109 000033 02 912400135768 DMX Ethernet 4 Wire Surface Mount 109 000034 00 912400135770 DMX Ethernet 3 Wire Surface Mount 109 000034 02 912400135772 Use Item Number...

Page 10: ...splays involves additional considerations such as how to space iColor Flex LMX gen2 nodes to achieve the desired pixel pitch minimum and maximum viewing distances sampling and display resolution All installations involve three main steps 1 Create a lighting design plan and layout grid 2 Mount strands 3 Address configure and test strands Owner User Responsibilities It is the responsibility of the c...

Page 11: ... as the distance to the display increases Likewise images appear less visible as the distance decreases The spacing between pixels known as the pixel pitch determines the minimum and maximum viewing distances for discernible video output Pixel pitch is measured center to center For an iColor Flex LMX gen2 strand you determine pixel pitch by measuring from the center of one node to the center of th...

Page 12: ...digital video output This method is especially effective when creating an installation that covers a building which by necessity already has spacing between lines of video due to windows and other architectural features Create a Lighting Design Plan and Layout Grid Even for relatively simple installations it s good practice to create a lighting design plan For complex installations displaying ligh...

Page 13: ...inning with the node closest to the leader cable Orientation of the power data supply is therefore especially critical when using dynamic effects In Ethernet environments each power data supply is identified with a unique IP address We recommend recording the IP address of each power data supply on a layout grid For complex installations with many power data supplies we recommend assigning meaning...

Page 14: ... gen2 Strands You can mount iColor Flex LMX gen2 strands directly to a mounting surface or you can mount them using optional mounting hardware available separately Mounting tracks ensure straight runs in linear applications If using strands with standard 4 in or 12 in on center spacing you can snap spacers to the mounting tracks for a clean finished look that hides cables and mounting hardware bet...

Page 15: ...ting Track 1 Cut mounting track to the desired length with a saw or snips 2 Using flathead screws suitable for the mounting surface drive screws through the plastic track into the attaching surface Recommended maximum spacing between screws is 406 mm 16 in 3 Snap the iColor Flex LMX gen2 nodes into the mounting track 3 If using strands with standard 4 in or 12 in on center spacing snap optional sp...

Page 16: ...nting Tracks and Accessory Spacers Mounting tracks ensure straight runs in linear applications If using strands with standard 4 in or 12 in on center spacing you can snap spacers to the mounting tracks for a clean finished look that hides cables and mounting hardware between nodes Mounting iColor Flex LMX gen2 Strands with Accessories Directly to a Mounting Surface 1 Using a pencil or chalk line m...

Page 17: ... diameter hole saw to cut openings in the substrate Openings should be a minimum of 35 6 mm 1 4 in in diameter and a maximum of 38 mm 1 5 in in diameter 2 Peel the backing from a lens or glare shield holder to expose the adhesive surface 3 Insert the lens or glare shield holder through an opening in the substrate and temporarily affix the lens holder by pressing the adhesive surface to the back of...

Page 18: ...n the glare shield with the slots in the glare shield holder and snap the glare shield onto the glare shield holder 5 Repeat steps 2 4 for each opening 6 Once all accessories are installed on the substrate mount iColor Flex LMX gen2 strands by inserting one node into the back of each lens or glare shield holder Press until the nodes snap firmly into the lens or glare shield holders ...

Page 19: ...rack to hide mounting hardware and wires Make Power and Data Connections iColor Flex LMX gen2 strands are designed to work with 24 VDC power data supplies from Philips Color Kinetics Power data supplies send power and data to iColor Flex LMX gen2 strands over a leader cable PDS 60ca 24V is an IP66 rated power data supply suitable for use in damp and wet locations Although sPDS 480ca 24V and sPDS 6...

Page 20: ... data supply for outdoor applications 1 Remove the power data supply cover 2 Remove the cover of the transmitter PCA junction box by expanding the four tabs on the side and sliding the cover from the base 3 Connect line common ground and data to the provided terminal block then replace the cover of the transmitter PCA junction box 4 Connect the leader cable connector to an available port inside th...

Page 21: ...ed in a DMX universe is 170 170 x 3 510 When using an sPDS 60ca 24V power data supply with DMX control you program the power data supply rather than addressing the iColor Flex LMX gen2 strands directly You use SmartJack Pro or iPlayer 3 with QuickPlay Pro addressing software to set a base DMX address for the power data supply and to specify the node quantity of each attached iColor Flex LMX gen2 s...

Page 22: ... and troubleshooting When readdressing power data supplies you will need the layout grid you created when you recorded each power data supply s IP address during installation planning For complete details on addressing and configuring strands controllers and power data supplies refer to the Addressing and Configuration Guide at www colorkinetics com support addressing or the User Guide or Specific...

Reviews: