4
September 2018
Application Guide - Philips GreenPower LED production module
Dimensions
W1
L1
L3
D2 (Ø)
D1 (Ø)
H1
L2
10 / 0.39
W1
32 / 1.26
40 / 1.57
H1
4
.5 / 0
.18
Technical specifications
Product name
Product dimensions (mm/inch)
Product
weight
(kg/lbs)
EU
NAM
L1
L2
L3
D1 Ø
D2 Ø
D2 Ø
W1
H1
GP LED production module 120
1213 / 47.76
700 / 27.5
64 / 2.52
19 / 0.75
8.7 / 0.34
7.6 / 0.3
40.5 / 1.59
40.2 / 1.58
1.4 / 3.1
GP LED production module 150
1513 / 59.57
700 / 27.5
64 / 2.52
19 / 0.75
8.7 / 0.34
7.6 / 0.3
40.5 / 1.59
40.2 / 1.58
1.7 / 3.7
Type
Photobiological hazard
2
Photon flux
Efficacy typical
1
Power
consumption
Radiation
hazard
Minimum viewing distance
3
All other radiation
hazards
(μmol/s)
(μmol/J)
(W)
Retinal Blue
(m)
(inch)
PM 120
DR/B 120 LB HO
66
3.0
22
Risk Group 2
0.35
14
Exempt group
DR/B/FR 120 LB HO
66
3.0
22
Risk Group 2
0.35
14
Exempt group
DR/B/FR_2 120 MB HO
64
2.7
24
Risk Group 2
0.8
32
Exempt group
DR/W 120 LB HO
66
2.6
25
Risk Group 2
0.5
20
Exempt group
DR/W/FR 120 LB HO
66
2.6
25
Risk Group 2
0.5
20
Exempt group
DR/W 120 LB LO
25
2.5
10
Exempt group
N/A
N/A
Exempt group
PM 150
DR/B 150 LB HO
83
3.0
28
Risk Group 2
0.35
14
Exempt group
DR/B/FR 150 LB HO
83
3.0
28
Risk Group 2
0.35
14
Exempt group
DR/W 150 LB HO
83
2.6
32
Risk Group 2
0.5
20
Exempt group
DR/W/FR 150 LB HO
83
2.6
32
Risk Group 2
0.5
20
Exempt group
DR/W 150 LB LO
31.5
2.5
12.5
Exempt group
N/A
N/A
Exempt group
DR/W 150 LB
62.5
2.6
24
Risk Group 2
0.3
12
Exempt group
FR 150
62.5
2.1
30
Exempt group
N/A
N/A
Exempt group
Specifications
Details
Optical
Rated average lifetime
1,4
35.000 hrs, L90B50 (90% flux maintenance)
Electrical
Input voltage
120 - 277 V AC, 50-60 Hz
Power factor
> 0,9 (> 0,8 for LO versions @ 277 V)
Inrush current
3.0 A - 0.8 ms 120 V
5.5 A - 0.8 ms 230V
7.0 A - 0.8 ms 277V
Environment
Ambient storage temperature
-20 to 85 °C / -4 to 185 °F (T
storage
)
Ambient operating temperature
0 to 40 °C / 40 to 104 °F (T
operating
)
Max. case temperature
1
40 °C / 104 °F (T
case
)
Cooling
Passively air-cooled
Relative humidity
5-95% RH, no condensation allowed during storage,
operation and application
Ingress protection rating
IP66
UL/CSA rating
Dry, damp and wet locations
Legend:
GP = GreenPower
PM = Production Module
DR = Deep Red
B = Blue
W = White
FR = Far Red
LB = Low Blue
HO = High Output
LO = Low Output
1
Efficacy typical / Rated average lifetime / Max. case temperature
@ T
ambient
= 25 °C / 77 °F
2
For more information about photobiological hazard see page 5
3
The luminaire should be positioned at minimum viewing distance,
so that prolonged staring into the light source is not expected.
4
All measured lifetimes are industry standard measurements
indicating average length of operation and not a performance
claim specific to any individual product.
Product information