GC7422

7-8

REPAIR INSTRUCTIONS

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

HOSE-CORD ASSY 3

 or 

CORDSET 55

, they must be replaced. 

Continued usage is not allowed.

-  When replacing the 

MICROSWITCH ASSY

, please dress the 2 attached wires such that they are free of tension. Pulling force on 

the wires may affect the steam triggering.

-  To avoid damage to the sealing & components of the 

BOILER ASSY 38

NEVER

 clean the boiler assy with vinegar, descaling 

agent or other corrosive chemicals.

- When replacing 

ELECTROVALVE 40

 or 

PUMP ASSY 45

, please be reminded to apply loctite at the joints for good sealing.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 minutes. 
The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

Summary of Contents for GC7422

Page 1: ...uld function properly and has to meet the safety requirements as officially laid down as this moment TECHNICAL INFORMATION Voltage 220 240 V Frequency 50 60 Hz Power Iron 800 W Boiler 1370 W Dimension F box 350 x 350 x 250 mm L x W x H Weight 6 4 kg Water advice If the tap water in your area is very hard it is advisable to mix the tap water with an equal amount of demineralised water Easy to rinse...

Page 2: ... Disassemble INLAY Disassemble SOS KNOB 10 Disengage Ribs of light ring Disassemble LAMP ASSY Remove Screw B Disassemble Switch holder Disassemble MICROSWITCH ASSY 4 Remove Screws C1 C2 C3 Disassemble HOSE CORD CABLE ASSY 13 Disassemble THERMOSTAT DIAL 20 Remove Screws D1 D2 D3 D4 Disassemble HOUSING PRINTED 6 Remove Screw E Disassemble SUB HOUSING Disassemble STEAM DEVIATOR ASSY 12 Remove Screws ...

Page 3: ...5 6 10 11 12 13 18 19 20 21 4239 021 51301 4239 015 70150 4239 026 38621 4239 021 44410 4239 026 13220 4239 021 56061 4239 026 38671 4239 015 57400 4239 021 31780 4239 021 56081 4239 026 38681 4239 014 54690 4239 021 56091 4239 026 38701 Soleplate mounted assy Ryton ring Cover SOS molded Microswitch assy Thermostat bush Housing printed SOS knob SOS seal Steam deviator assy Hose cord mounted assy T...

Page 4: ...PLODED VIEW IRON 10 20 18 6 3 1 11 Light ring Switch holder 12 5 4 21 2 13 19 F2 F1 F3 E D3 D4 D1 C1 C2 C3 A D2 B Screw Dimension A C E Ø 3 5 mm x 13 mm B D Ø 2 6 mm x 9 6 mm F1 M4 0 mm x 10 mm F2 F3 M4 0 mm x 16 mm ...

Page 5: ... Remove Screws K1 K2 K3 K4 Disconnect INLET TUBE PUMP Disconnect DE AIR TUBE Disassemble WATER TANK ASSY 34 Disassemble BRAIDED RUBBER HOSE BOILER Disassemble PUMP ASSY 45 Remove Torx screws L1 L2 L3 Disassemble TOP SPACER Disassemble BOILER ASSY 38 PARTS LIST STAND Note For Pos 45 please replace both components together when either one is faulty The 2 components come as a service kit Pos Service ...

Page 6: ...GC7422 6 8 EXPLODED VIEW STAND F1 K1 H1 H2 K2 K4 K3 F2 G F3 40 56 38 42 34 36 52 50 65 55 44 45 Cord clamp Clamping plate 37 L2 L3 L1 30 33 58 67 ...

Page 7: ...ed to the consumer 1 Soleplate temperature Check that soleplate temperature is within IEC requirement Measure the temperature of the soleplate after the iron has reached steady state i e connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 9...

Page 8: ...GC7422 8 8 REPAIR INSTRUCTIONS Pump Assy Wire connections Connector positions in DOTTED circle cannot be interchanged Single wire connector BLACK BLACK A LIGHT GREY Dual wire connector ...

Reviews: