background image

GC4430

REPAIR INSTRUCTIONS & ELECTRICAL DIAGRAM

-  Due to the high wattage of the iron, only the specified cord set must be used.

-  Should damage be observed on the 

CORDSET 26

, it must be replaced. 

Continued usage is not allowed.

- If 

COVER 1

 is provided without type plate information eg. type number, voltage etc. When replacing the cover, engrave the type 

number & voltage on the type plate with a sharp object.

-  After the product has been repaired, it should function properly and has to meet the safety requirements & legal regulations as 

laid down & officially established at this moment.

-  The following tests are common checks that are conducted on a repaired product before it is returned to the consumer.

1. 

Soleplate temperature

Check that soleplate temperature is within IEC requirement.

Measure the temperature of the soleplate after the iron has reached steady state i.e connected to the mains for at least 15 
minutes. The table below shows the temperature requirement.

Marking

Soleplate temperature (Deg C)

Material, for example

Test-
point

==

Minimum Maximum N Tolerance

 (1 

dot)

  70

120

  95 ± 25

Acetate, elastane, polyamide, polyproylene

••

 (2 

dots)

100

160

130 ± 30

Cupro, polyester, silk, triacetate, viscose, wool

•••

 (3 dots)

140

210

175 ± 35

Cotton, linen

2. 

Leakage current

Check that leakage current is within IEC requirement.

Measure leakage current between LIVE/NEUTRAL & EARTH.
IEC requirement is that at 230 V supply, the EARTH leakage current must be less than 0.75 mA.

3. 

Water leakage / Functionality

Check that there is no water leakage from any part of the product during operation.

Check that the functionality of the product (product dependent) eg. steaming, variable steam, SOS, ASO etc is working 
properly.

4. 

Loose part

Check that there are no loose parts eg. extra screw in the product that can cause short-circuit or product malfunction.

Brown

L

E

INPUT

Blue

N

White

ASO

Control

Unit

Red

Black

Heating
Element

Thermostat Thermal

Fuse

Ionizer

Module

3-5

Summary of Contents for GC4430

Page 1: ...ce Suitable for tap water use Advice to mix with equal portion of distilled water or use only distilled water if the tap water is very hard Ionic Deep Steam Ionization process produces smaller steam particles The finer steam leads to deeper better penetration into fabrics SteamGlide Soleplate The specially treated SteamGlide soleplate is designed with 2 distinctly different types of steam vents 1 ...

Page 2: ...HETIC RING 31 SOFTTOUCH SNAP ON 35 LI NN E B W OL LE WO LLE NYLO N NYLO N YLL E SEID E SILK E BO MU LE LE IN EN Remove Thermostat dial Remove Screws C1 C2 Remove Screws D1 D2 Remove HOUSING 22 WATERTANK ASSY 14 PUMP ASSY 16 SPRAY NOZZLE ASSY 17 STEAM SHAFT ASSY 18 DOSING CAM 19 CLAMP BRACKET 20 Remove Screws E1 E2 Remove Screw F Remove WATER TANK ASSY 14 Remove Screws G1 G2 Remove CLAMP BRACKET 20...

Page 3: ...connected to the mains for at least 15 minutes The table below shows the temperature requirement Marking Soleplate temperature Deg C Material for example Test point Minimum Maximum Nominal Tolerance 1 dot 70 120 95 25 Acetate elastane polyamide polyproylene 2 dots 100 160 130 30 Cupro polyester silk triacetate viscose wool 3 dots 140 210 175 35 Cotton linen 2 Leakage current Check that leakage cur...

Page 4: ... ice Cover sprayed inscribed Tonic ice East EU Cover sprayed inscribed Tonic ice Swiss Soleplate mounted assy 120 V Soleplate mounted assy 230 V SOS seal Ryton spacer Dosing seal Heat shield Backplate White Ball swive White Backplate cover Transparent grey Filling door assy Transparent grey Inlay assy White Lamp cover Steam slider Transparent grey Water tank assy Transparent grey Water tank assy T...

Page 5: ...GC4430 EXPLODEDVIEW MAX G2 C1 C2 D2 D1 B1 B2 B2 B2 A G1 E1 E2 H3 H2 H1 29 23 33 9 27 14 12 8 28 6 1 32 22 35 4 2 31 18 36 7 19 20 38 5 3 15 17 21 25 24 30 10 26 11 13 34 16 5 5 ...

Reviews: