8.0 TEST
PROCEDURES
8.1
Initial Functional Check for Fisio 620-CT3328 and Fisio 625-CT3329
Before to start the test procedure check the appearance of the humidity sticker located at the back of the phone.
Refer to CASES OUT OF WARRANTY GSM document to identify if the product is in/out of warranty.
8.1.1
Insert the Test Production Card into the SIM Reader at the back of the cellular phone and clip a charged
battery on the phone.
8.1.2 Press
the
«ON» button for 2 seconds at least and the LCD will show a message which contains information
of FA (Final Adjustment) status and 12NC.
8.1.3
Follow the instructions as mentioned below :
PAGE SELECTION 00
Step
Procedure
Observation
1
Press Key 1
Press Key 1 again.
Key without Test
Left corner displays 1
00
2
Press key 2
(Audio loop local effect)
Press key 2 again
"LocalEffect"
" XX XX XX“
“ XX XX”
Left corner displays 2
01
3
Press key 3
Audio loop test (Speak to Mic
and listen echo from Speaker)
Press key 3 again
"AUDIO xx xx xx xx”
"EEP xx xx xxxx ”
Left corner displays 3
02
4
Press key 4
Check for the Backlight
function in the same time.
Press key 4 again
Backlight must be on
Left corner displays 4
03
5
Press Key 5
(Checkerboard test)
Press Key 5 again
Checkerboard 1 pixel on
Left corner displays 5
04
6
Press Key 6
(Inverted Checkerboard)
Press Key 6 again
Checkerboard 2 pixel on
Left corner displays 6
05