![Philips EP Series Service Manual Download Page 4](http://html.mh-extra.com/html/philips/ep-series/ep-series_service-manual_1539705004.webp)
6
7
Water circuit
Electric circuit
Coffee and machine specifications
Specific tools and equipment
Drinks
Low button
( ml)
Medium button
(ml)
High button
(ml)
Volume adjustment
(only at high button - ml)
Espresso
30
40
70
40-220
Coffee
100
120
200
120-220
Espresso lungo
60
80
180
80-220
Americano
(water)
40
(50)
40
(110)
40
(160)
40
(110-360)
Cappuccino
(milk)
30
(90)
40
(120)
60
(200)
40-220
(120-340)
Latte macchiato
(milk)
30
(120)
40
(200)
50
(340)
40-220
(200-340)
Hot water
60
150
360
150-360
Coffee grounds drawer
Description and values
Time-out for coffee grounds drawer
5 seconds
Reset dreg counter
Dreg emptying alarm, if the coffee grounds drawer is removed for
more than 5 seconds.
STANDBY
Description and values
Time (default)
15 minutes
Time programmed by Consumer/Service
NO
Boiler temperature during Standby
Boiler OFF
WATER TANK
Description and values
Water reserve (pulses) with water filter
125 ml (260 pulses)
Water reserve (pulses) with no water filter
125 ml (260 pulses)
Water reserve modifiable by Production/Service departments
NO
“Fill tank” alarm
YES
Connect to water mains
NO
Description
Notes
Flathead screwdriver
# 0, # 2
Torx screwdriver
(T10)
Pliers for Oetiker clamps
Digital Thermometer
Type K (accuracy for temperature of 0,05 % or ± 0,3°C)
Temperature probe
80PK-22 (80AK-A Thermocouple adapter required)
Scale
KERN EMB 500-1 or comparable device with a base accuracy of
0,05 % or ± 0,5 g
Power meter
Voltcraft EnergyCheck 3000 or comparable device with a base
accuracy of 1 % or ± 5W
Stopwatch
Basic model
Serkit
Tool needed for programming with our service tool
EP series cable
Cable for Philips EP1200-2200-3200 series
EPSC (Espresso Philips Service Center)
Tool used to flash the SW on the machines (for SW upgrade and
diagnostics mode). Refer to SDA_114585
Technical information
Technical information