![Philips EP Series Service Manual Download Page 11](http://html.mh-extra.com/html/philips/ep-series/ep-series_service-manual_1539705011.webp)
20
21
Removal of the Gear motor
1.
Take out the brew unit motor cover removing the 2 screws
Be aware there is an empty hole (in the red circle). Do not insert any screw inside
Removal of the Boiler
1.
Remove all the electrical and water circuit connections
2. Take out the 2 screws from the boiler support.
Removal of the Flowmeter
1.
Remove the electric connection
2. Press on the holder to pull out the flowmeter, then remove water connections.
Removal of the Mainboard
1.
Remove all the electric connections
2. Keep pressing on the left holder to be able to release the board.
The mainboard contains several fixed wires which cannot be disconnected from the board.
The UI cable is also fixed to the mainboard.
To completely remove the mainboard from the appliance, disconnect all fixed wires from their destination component.
Removal of the Pump
1. Pull the pump holder to the right
2. Remove all the connection
When reassembling the pump, ensure to use hot melt to fix the thermal fuse.
Disassembly - and Reassembly advice
Disassembly - and Reassembly advice