ColorBlast TRX Product Guide
4
Specifications
Due to continuous improvements and innovations, specifications may change without notice.
Item
Specification
10° Beam Angle
23° Beam Angle
Output
Beam Angle
10°
23°
Lumens
†
1577
1372
Electrical
Input Voltage
24 VDC
Power Consumption
50 W maximum at full output, steady state
Control
Interface
DMX via PDS-750 TRX, PDS-750 TR, PDS-375 TR PDS-150e, or
PDS-60 24V. Fixture firmware addressable 8- or 16-bit control,
RGBAW or RGB modes
Control System
Philips full range of controllers, including Light System Manager
and iPlayer 3, or third-party controllers
Physical
Dimensions
(Height x Width x Depth)
8 x 14 x 3 in (203 x 356 x 76 mm)
Weight
7.25 lb (3.3 kg)
Housing
Die-cast aluminium, powder-coated black finish
Lens
Clear glass
Frosted glass
Fixture Connections
6 ft (1.8 m) power / data cable with 4-pin XLR connector
Temperature Ranges
-40° – 122° F (-40° – 50° C) Operating
-
4
° – 122° F (-20° – 50° C) Startup
-40° – 176° F (-40° – 80° C) Storage
Humidity
0 – 95%, non-condensing
Maximum Cable Length
175 ft (53.3 m), with extension to built-in 6 ft (1.8 m) power
cable
Certification
and Safety
Certification
UL / cUL, FCC Class A, CE
LED Class
Class 2 LED product
Environment
Dry / Damp Location, IP22
†
Lumen measurement complies with IES LM-79-08
.
∅
0.5 in
(13 mm)
∅
0.2 in
(5 mm) 4x
∅
3.5 in
(89 mm)
2.2 in
(56 mm)
14 in
(356 mm)
5.75 in
(146 mm)
8 in
(203 mm)
6.875 in
(175 mm)
4.5 in
(114 mm)
3 in
(76 mm)
For details on the PDS-750 TR and PDS-750 TRX
power / data supplies, visit the City Theatrical Inc.
website at www.citytheatrical.com.
10º Beam Angle
23º Beam Angle
110º Rotation
110º
110º
Lumen Maintenance
Lumen maintenance values are based on
measurements that comply with IES LM-80-08 testing
procedures. See www.colorkinetics.com/support/
appnotes/lm-80-08.pdf for more information.
Ambient Temps.
L
70
*
L
50
†
5 RGBAW Channels Full On
@ 25° C
60,000 hours
100,000 hours
@ 50° C
50,000 hours
80,000 hours
* L
70
= 70% maintenance of lumen output (when light output drops below 70% of initial output).
† L
50
= 50% maintenance of lumen output (when light output drops below 50% of initial output).