ColorBlast TRX Product Guide
3
Photometrics
Photometric data is based on test results from an independent NIST traceable testing lab.
IES data is available at www.colorkinetics.com/support/ies.
For lux multiply fc by 10.7
Center Beam fc
Beam Width
4.0 ft
8.0 ft
12.0 ft
16.0 ft
20.0 ft
24.0 ft
1877 fc
469 fc
209 fc
117 fc
75 fc
52 fc
0.8 ft
1.6 ft
2.4 ft
3.2 ft
4.0 ft
4.7 ft
0.8 ft
1.6 ft
2.3 ft
3.1 ft
3.9 ft
4.7 ft
�
�
Vert. Spread: 11.3º
�
�
Horiz. Spread: 11.1º
Illuminance at Distance
ColorBlast TRX
10° beam angle
Candela Table
0.0 22.5 45.0 67.5 90.0
0 30035 30035 30035 30035 30035
5 17025 16960 16878 16659 16703
15 965 1016 1073 1001 832
25 57 60 61 61 108
35 19 20 17 20 54
45 8 7 8 9 11
55 3 4 2 3 5
65 2 2 0 1 0
75 0 0 0 0 0
85 0 0 0 0 0
90 0 0 0 0 0
Polar Candela Distribution
Effective Floor Cavity Reflectance: 20%
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 119119119119 116116116116 111111111 106106106 102102102 100
1 116114113112 114112111110 108107107 105104103 101101100 99
2 114111108107 112109107105 106105103 103102101 101100 99 98
3 111108105103 110107104102 104102101 102100 99 100 99 98 97
4 109105102100 108104102100 102100 99 101 99 98 99 98 97 96
5 107103100 98 106102100 98 101 99 97 100 98 96 98 97 95 95
6 106101 99 96 105101 98 96 100 97 96 99 97 95 97 96 94 94
7 104100 97 95 103 99 97 95 98 96 94 98 96 94 97 95 94 93
8 103 99 96 94 102 98 96 94 97 95 93 97 95 93 96 94 93 92
9 102 97 95 93 101 97 94 93 96 94 92 96 94 92 95 93 92 91
10 101 96 94 92 100 96 93 92 95 93 92 95 93 91 94 93 91 91
Coefficients Of Utilization -
Zonal Cavity Method
Zonal Lumen Summary
0- 30 1550 98.3
0- 40 1567 99.3
0- 60 1576 99.9
0- 90 1577 100.0
90-180 0 0.0
0-180 1577 100.0
Zone Lumens %Fixture
Zonal Lumen
173.5 ft (52.9 m)
1 fc maximum distance
Cd: 0
5,167
10,333
15,500
20,667
25,833
31,000
VA: 0º
10º 20º
30º
40º
90º
80º
70º
60º
50º
�
- 0º H
�
- 90º H
LED
Lumens Efficacy
RGB
1577
27.0
Center Beam fc
Beam Width
4.0 ft
8.0 ft
12.0 ft
16.0 ft
20.0 ft
24.0 ft
314 fc
79 fc
35 fc
20 fc
13 fc
9 fc
1.7 ft
3.4 ft
5.1 ft
6.7 ft
8.4 ft
10.1 ft
1.7 ft
3.3 ft
5.0 ft
6.7 ft
8.3 ft
10.0 ft
�
�
Vert. Spread: 23.8º
�
�
Horiz. Spread: 23.5º
Illuminance at Distance
ColorBlast TRX
23° beam angle
Candela Table
0.0 22.5 45.0 67.5 90.0
0 5028 5028 5028 5028 5028
5 4438 4438 4424 4418 4410
15 1748 1752 1745 1734 1731
25 499 501 501 501 503
35 173 174 176 179 183
45 82 82 84 86 89
55 47 47 48 51 52
65 26 27 28 30 31
75 11 12 13 14 15
85 1 1 1 2 2
90 0 0 0 0 0
Polar Candela Distribution
Effective Floor Cavity Reflectance: 20%
RC 80 70 50 30 10 0
RW 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
0 119119119119 116116116116 111111111 106106106 102102102 100
1 114111109107 111109107105 105103102 101100 99 98 97 96 94
2 109104101 97 107103 99 96 99 97 94 97 94 92 94 92 90 89
3 104 98 94 90 102 97 93 90 94 91 88 92 89 87 90 87 85 84
4 100 93 88 84 98 92 88 84 90 86 83 88 85 82 86 83 81 80
5 96 89 83 80 94 88 83 79 86 82 79 84 81 78 83 80 77 76
6 92 85 79 76 91 84 79 75 82 78 75 81 77 74 80 77 74 73
7 89 81 76 72 88 80 75 72 79 75 72 78 74 71 77 74 71 70
8 86 78 73 69 85 77 72 69 76 72 69 75 71 68 74 71 68 67
9 83 75 70 66 82 74 70 66 73 69 66 73 69 66 72 68 66 65
10 80 72 67 64 79 72 67 64 71 67 64 70 66 64 70 66 63 62
Coefficients Of Utilization -
Zonal Cavity Method
Zonal Lumen Summary
Zone Lumens %Fixture
0- 30 1102 80.3
0- 40 1216 88.7
0- 60 1328 96.8
0- 90 1372 100.0
90-180 0 0.0
0-180 1372 100.0
Zonal Lumen
71 ft (21.6 m)
1 fc maximum distance
Cd: 0
850
1,700
2,550
3,400
4,250
5,100
VA: 0º
10º 20º
30º
40º
90º
80º
70º
60º
50º
�
- 0º H
�
- 90º H
LED
Lumens Efficacy
RGB
1372
23.5