10.2.11 The mode switch
By use of a combination of different voltage levels at CTRL-L1 and CTRL-L2 each mode of the CPSU can be passed on
to the Delegate and Chairman units.
6
2
9
5
4
8
2
7
25
Ω
X205 Mx*
Mx
Signal
M30
*
M31
M32
M33
M4
M5
BIT 0
BIT 1
BIT 3
CTRL-L1
CTRL-L2
BIT 2
X150
X110
S240
X10
AC
24V DC
Power Supply
90 ... 264V AC
~
~
Loudspeaker
PCB CPSU
M110 M111
M121
M122 M124
M150 M151
M2
GND
(GND)
(GND)
(GND)
+
-
A1
V
L
R
IN
Rec-IN
Line-IN
Rec-IN
Telephone
003_013.cdr
Figure 13
Set the “mode switch” (S240) is each position and measure the voltages at M30, M31, M32, M33, M4 and M5 related to
M2 (GND).
Mode switch
Measurement values for A1 (V)
position (S240)
M33 (bit 3)
M32 (bit 2)
M31 (bit 1)
M30 (bit 0)
M4 (Control-L1)
M5 (Control-L2)
Auto-1
0
10
0
0
2.5
2.9
Auto-2
0
10
0
10
2.5
2.9
Auto-3
0
10
10
0
2.5
2.9
Auto-4
0
10
10
10
2.5
2.9
Open-1
0
15
0
0
2.5
5.7
Open-2
0
15
0
10
2.5
5.7
Open-3
0
15
10
0
2.5
5.7
Open 4
0
15
10
10
2.5
5.7
Override
10
10
0
0
1.0
5.7
Chairman only
10
10
0
10
1.0
>14
Test
10
10
10
0
2.5
1.0
Tolerances:
10V ±500 mV
15V ±750mV