SERVICE MANUAL
LBB 3310/00, 3330/00 and 3331/00
page: 19
Date of issue:
4822 861 11006
July 1998
Nominal level, maximum level and bandwidth
Connect a sine-wave generator to one Trunk connectors (X11) and measure the output signal at the other Trunk
connector (X12) according to figure 7.
6
2
9
5
4
8
2
7
25
Ω
X205
X150
X110
X10
AC
24V DC
Power Supply
90 ... 264V AC
~
~
Loudspeaker
PCB CPSU
M110 M111
M121
M122 M124
M150 M151
(GND)
(GND)
(GND)
X11
M2
M1
GND
1
Audio Contr.
Trunk
SHIELD
L
R
IN
Rec-IN
Line-IN
Rec-IN
Telephone
X12
Trunk
+
-
A1
V
GND
3
M2
M3
G1
Sine-Wave
Generator
+
-
003_007.cdr
Figure 7
settings for G1
measurement results for A1
Amplitude
Frequency
Amplification
Nominal level
-36dBV (15.8 mVrms)
1kHz
-9.4dBV +/- 1dB (85dB SPL)
Overload level
-11dBV (281.8 mVrms)
1 kHz
+3dBV +/- 1dB (115dB SPL)
Bandwidth
-36dBV (15.8mVrms)
125 Hz
-2dB +/- 2dB related to nom. level at 1kHz
Bandwidth
-36dBV (15.8mVrms)
12.5 kHz
-1dB +/- 1dB related to nom. level at 1kHz.