Calculite
®
HID Lensed Downlight
C4T4GD-MHT4R
Page 2 of 4
4 1/2" Aperture, T4.5 Ceramic Metal Halide, Glasslite
39W T4.5
Ceramic MH,
Narrow Flood
Upper Reflector, Philips, Lumen Rating = 3400 LMS., Aromat Electronic Ballast
2,250
4,500
6,750
9,000
30°
60°
ANGLE
MEAN CP
LUMENS
0
8996
5
7584
10
4322
15
2225
20
1047
25
452
30
169
35
81
40
53
45
39
50
32
55
26
60
20
65
12
70
7
75
5
80
3
85
0
90
0
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
1459
42.92
91.95
0-40
1515
44.58
95.5
0-60
1569
46.16
98.88
0-90
1587
46.68
100
40-90
71
2.1
4.5
60-90
17
0.52
1.12
90-180
0
0
0
0-180
1587
46.68
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
7690
55
6459
65
3966
75
2612
85
0
** Efficiency = 46.7% ** SC = .3
Certified Test Report No. 18678FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
CEILING
80%
70%
50%
30%
WALL
70 50 30 10
50 10
50 10
50 10
0
RCR
0
.56 .56 .56 .56
.54 .54
.52 .52
.50 .50
.47
1
.54 .53 .52 .51
.52 .51
.50 .49
.48 .48
.46
2
.52 .51 .50 .49
.50 .48
.49 .47
.47 .46
.44
3
.51 .49 .48 .47
.48 .46
.47 .46
.46 .45
.44
4
.50 .48 .46 .45
.47 .45
.46 .44
.45 .44
.43
5
.49 .46 .45 .43
.46 .43
.45 .43
.44 .42
.42
6
.48 .45 .43 .42
.45 .42
.44 .42
.44 .42
.41
7
.46 .44 .42 .41
.44 .41
.43 .41
.43 .41
.40
8
.46 .43 .41 .40
.43 .40
.42 .40
.42 .40
.39
9
.45 .42 .41 .39
.42 .39
.42 .39
.41 .39
.39
10
.44 .41 .40 .38
.41 .38
.41 .38
.40 .38
.38
LUMINAIRE INPUT WATTS = 44
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
70W T4.5
Ceramic MH,
Narrow Flood
Upper Reflector, Philips, Lumen Rating = 6200 LMS., Aromat Electronic Ballast
3,750
7,500
11,250
15,000
30°
60°
ANGLE
MEAN CP
LUMENS
0
13659
5
11121
915
10
6556
15
3509
990
20
1859
25
942
441
30
400
35
177
125
40
105
45
78
62
50
65
55
55
49
60
43
65
29
30
70
20
75
11
12
80
6
85
1
2
90
0
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
2346
37.85
89.35
0-40
2471
39.87
94.11
0-60
2582
41.65
98.32
0-90
2626
42.36
100
40-90
154
2.49
5.89
60-90
44
0.71
1.68
90-180
0
0
0
0-180
2626
42.36
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
15547
55
13566
65
9819
75
6013
85
2289
** Efficiency = 42.4% ** SC = .3
Certified Test Report No.18753FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
CEILING
80%
70%
50%
30%
WALL
70 50 30 10
50 10
50 10
50 10
0
RCR
0
.50 .50 .50 .50
.49 .49
.47 .47
.45 .45
.42
1
.49 .48 .47 .46
.47 .46
.45 .44
.44 .43
.41
2
.47 .46 .45 .44
.45 .43
.44 .42
.43 .41
.40
3
.46 .44 .43 .42
.44 .41
.43 .41
.42 .40
.39
4
.45 .43 .41 .40
.42 .40
.41 .39
.41 .39
.38
5
.44 .41 .40 .39
.41 .38
.40 .38
.40 .38
.37
6
.43 .40 .39 .37
.40 .37
.39 .37
.39 .37
.36
7
.41 .39 .37 .36
.39 .36
.38 .36
.38 .36
.35
8
.41 .38 .36 .35
.38 .35
.37 .35
.37 .35
.34
9
.40 .37 .36 .34
.37 .34
.37 .34
.36 .34
.34
10
.39 .36 .35 .34
.36 .34
.36 .34
.36 .33
.33
LUMINAIRE INPUT WATTS = 78
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
39W T4.5
Ceramic MH,
Flood
Upper Reflector, Philips, Lumen Rating = 3400 LMS. Aromat Electronic Ballast
500
1000
1500
2000
500
1,000
1,500
2,000
30°
60°
ANGLE
MEAN CP
LUMENS
0
1992
5
1944
184
10
1822
15
1660
444
20
1226
25
706
322
30
315
35
139
95
40
66
45
36
31
50
30
55
26
23
60
21
65
16
16
70
11
75
7
8
80
4
85
1
2
90
0
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
949
27.94
84.42
0-40
1045
30.74
92.9
0-60
1099
32.34
97.74
0-90
1125
33.09
100
40-90
79
2.35
7.1
60-90
25
0.75
2.26
90-180
0
0
0
0-180
1125
33.09
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
7192
55
6459
65
5333
75
3973
85
2101
** Efficiency = 33.1% ** SC = .7
Certified Test Report No.18679FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
CEILING
80%
70%
50%
30%
WALL
70 50 30 10
50 10
50 10
50 10
0
RCR
0
.39 .39 .39 .39
.37 .38
.38 .38
.35 .35
.33
1
.38 .37 .37 .36
.35 .37
.37 .35
.34 .33
.32
2
.37 .35 .34 .33
.33 .36
.35 .33
.33 .32
.30
3
.35 .34 .33 .31
.32 .35
.33 .31
.32 .30
.29
4
.34 .32 .31 .30
.30 .34
.32 .30
.31 .29
.28
5
.33 .31 .30 .28
.29 .33
.31 .28
.30 .28
.27
6
.32 .30 .28 .27
.28 .32
.30 .27
.29 .27
.26
7
.31 .29 .27 .26
.27 .31
.29 .26
.28 .26
.25
8
.30 .28 .26 .25
.26 .30
.27 .25
.27 .25
.25
9
.29 .27 .25 .24
.25 .29
.27 .24
.26 .24
.24
10
.28 .26 .24 .23
.24 .28
.26 .23
.25 .23
.23
LUMINAIRE INPUT WATTS = 44
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
70W T4.5
Ceramic MH,
Flood
Upper Reflector, Philips, Lumen Rating = 6200 LMS., Aromat Electronic Ballast
750
1,500
2,250
3,000
30°
60°
ANGLE
MEAN CP
LUMENS
0
3172
5
3144
303
10
3054
15
2810
763
20
2215
25
1361
618
30
668
35
279
194
40
125
45
67
57
50
55
55
47
42
60
39
65
29
29
70
20
75
13
14
80
8
85
3
3
90
0
ZONAL LUMENS AND PERCENTAGES
ZONE
LUMENS % LAMP %LUMINAIRE
0-30
1684
27.16
83.2
0-40
1878
30.29
92.79
0-60
1977
31.9
97.71
0-90
2024
32.65
100
40-90
145
2.35
7.21
60-90
46
0.75
2.29
90-180
0
0
0
0-180
2024
32.65
100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE
MEAN CD/SQ M
45
13385
55
11655
65
9620
75
7313
85
4282
** Efficiency = 32.6% ** SC = .7
Certified Test Report No.18755FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**
CEILING
80%
70%
50%
30%
WALL
70 50 30 10
50 10
50 10
50 10
0
RCR
0
.39 .39 .39 .39
.38 .38
.36 .36
.35 .35
.33
1
.37 .37 .36 .35
.36 .35
.35 .34
.33 .33
.31
2
.36 .35 .34 .33
.34 .32
.33 .32
.32 .31
.30
3
.35 .33 .32 .31
.33 .31
.32 .30
.31 .30
.29
4
.34 .32 .30 .29
.31 .29
.31 .29
.30 .29
.28
5
.32 .30 .29 .28
.30 .28
.30 .28
.29 .27
.27
6
.31 .29 .28 .27
.29 .27
.29 .27
.28 .26
.26
7
.30 .28 .27 .26
.28 .25
.27 .25
.27 .25
.25
8
.29 .27 .26 .25
.27 .24
.27 .24
.26 .24
.24
9
.28 .26 .25 .24
.26 .24
.26 .23
.25 .23
.23
10
.28 .25 .24 .23
.25 .23
.25 .23
.25 .23
.22
LUMINAIRE INPUT WATTS = 78
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%