background image

Job Information 

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609

Calculite

®

 HID Lensed Downlight

  C4T4GD-MHT4R

Page 2 of 4 

4 1/2" Aperture, T4.5 Ceramic Metal Halide, Glasslite

39W T4.5

 Ceramic MH, 

Narrow Flood

 Upper Reflector, Philips, Lumen Rating = 3400 LMS., Aromat Electronic Ballast

2,250

4,500

6,750

9,000

30°

60°

  ANGLE 

MEAN CP 

LUMENS

 

8996

 

7584

 

10 

4322

 

15 

2225

 

20 

1047

 

25 

452

 

30 

169

 

35 

81

 

40 

53

 

45 

39

 

50 

32

 

55 

26

 

60 

20

 

65 

12

 

70 

7

 

75 

5

 

80 

3

 

85 

0

 

90 

0

ZONAL LUMENS AND PERCENTAGES

  ZONE 

LUMENS  % LAMP  %LUMINAIRE

 

0-30 

1459 

42.92 

91.95

 

0-40 

1515 

44.58 

95.5

 

0-60 

1569 

46.16 

98.88

 

0-90 

1587 

46.68 

100

  40-90 

71 

2.1 

4.5

  60-90 

17 

0.52 

1.12

  90-180 

0

  0-180 

1587 

46.68 

100

LUMINANCE SUMMARY - CD. / SQ. M. 

 

ANGLE 

MEAN CD/SQ M

 

45 

7690

 

55 

6459

 

65 

3966

 

75 

2612

 

85 

0

**  Efficiency = 46.7%  **  SC = .3 

Certified Test Report No. 18678FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**

  

  

     CEILING 

80% 

70% 

50% 

30%

        WALL  

 70   50   30   10 

  50   10 

 50   10 

 50   10 

  0 

RCR
 

.56  .56  .56  .56 

.54  .54 

.52  .52 

.50  .50 

.47

 

.54  .53  .52  .51 

.52  .51 

.50  .49 

.48  .48 

.46

 

.52  .51  .50  .49 

.50  .48 

.49  .47 

.47  .46 

.44

 

.51  .49  .48  .47 

.48  .46 

.47  .46 

.46  .45 

.44

 

.50  .48  .46  .45 

.47  .45 

.46  .44 

.45  .44 

.43

 

.49  .46  .45  .43 

.46  .43 

.45  .43 

.44  .42 

.42

 

.48  .45  .43  .42 

.45  .42 

.44  .42 

.44  .42 

.41

 

.46  .44  .42  .41 

.44  .41 

.43  .41 

.43  .41 

.40

 

.46  .43  .41  .40 

.43  .40 

.42  .40 

.42  .40 

.39

 

.45  .42  .41  .39 

.42  .39 

.42  .39 

.41  .39 

.39

 

10 

.44  .41  .40  .38 

.41  .38 

.41  .38 

.40  .38 

.38

 

 

 

 

LUMINAIRE INPUT WATTS = 44

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% 

70W T4.5

 Ceramic MH, 

Narrow Flood

 Upper Reflector, Philips, Lumen Rating = 6200 LMS., Aromat Electronic Ballast

3,750

7,500

11,250

15,000

30°

60°

  ANGLE 

MEAN CP 

LUMENS

 

13659 

 

11121 

915

 

10 

6556 

 

15 

3509 

990

 

20 

1859 

 

25 

942 

441

 

30 

400 

 

35 

177 

125

 

40 

105 

 

45 

78 

62

 

50 

65 

 

55 

55 

49

 

60 

43 

 

65 

29 

30

 

70 

20 

 

75 

11 

12

 

80 

 

85 

2

 

90 

ZONAL LUMENS AND PERCENTAGES

  ZONE 

LUMENS  % LAMP  %LUMINAIRE

 

0-30 

2346 

37.85 

89.35

 

0-40 

2471 

39.87 

94.11

 

0-60 

2582 

41.65 

98.32

 

0-90 

2626 

42.36 

100

  40-90 

154 

2.49 

5.89

  60-90 

44 

0.71 

1.68

  90-180 

0

  0-180 

2626 

42.36 

100

LUMINANCE SUMMARY - CD. / SQ. M. 

 

ANGLE 

MEAN CD/SQ M

 

45 

15547

 

55 

13566

 

65 

9819

 

75 

6013

 

85 

2289

**  Efficiency = 42.4%  **  SC = .3 

Certified Test Report No.18753FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**

  

  

     CEILING 

80% 

70% 

50% 

30%

        WALL  

 70   50   30   10 

  50   10 

 50   10 

 50   10 

  0 

RCR
 

.50  .50  .50  .50 

.49  .49 

.47  .47 

.45  .45 

.42

 

.49  .48  .47  .46 

.47  .46 

.45  .44 

.44  .43 

.41

 

.47  .46  .45  .44 

.45  .43 

.44  .42 

.43  .41 

.40

 

.46  .44  .43  .42 

.44  .41 

.43  .41 

.42  .40 

.39

 

.45  .43  .41  .40 

.42  .40 

.41  .39 

.41  .39 

.38

 

.44  .41  .40  .39 

.41  .38 

.40  .38 

.40  .38 

.37

 

.43  .40  .39  .37 

.40  .37 

.39  .37 

.39  .37 

.36

 

.41  .39  .37  .36 

.39  .36 

.38  .36 

.38  .36 

.35

 

.41  .38  .36  .35 

.38  .35 

.37  .35 

.37  .35 

.34

 

.40  .37  .36  .34 

.37  .34 

.37  .34 

.36  .34 

.34

 

10 

.39  .36  .35  .34 

.36  .34 

.36  .34 

.36  .33 

.33

 

 

 

 

LUMINAIRE INPUT WATTS = 78

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% 

39W T4.5

 Ceramic MH, 

Flood 

Upper Reflector, Philips, Lumen Rating = 3400 LMS. Aromat Electronic Ballast

 500 

 1000 

 1500 

 2000 

500

1,000

1,500

2,000

30°

60°

  ANGLE 

MEAN CP 

LUMENS

 

1992 

 

1944 

184

 

10 

1822 

 

15 

1660 

444

 

20 

1226 

 

25 

706 

322

 

30 

315 

 

35 

139 

95

 

40 

66 

 

45 

36 

31

 

50 

30 

 

55 

26 

23

 

60 

21 

 

65 

16 

16

 

70 

11 

 

75 

8

 

80 

 

85 

2

 

90 

ZONAL LUMENS AND PERCENTAGES

  ZONE 

LUMENS  % LAMP  %LUMINAIRE

 

0-30 

949 

27.94 

84.42

 

0-40 

1045 

30.74 

92.9

 

0-60 

1099 

32.34 

97.74

 

0-90 

1125 

33.09 

100

  40-90 

79 

2.35 

7.1

  60-90 

25 

0.75 

2.26

  90-180 

0

  0-180 

1125 

33.09 

100

LUMINANCE SUMMARY - CD. / SQ. M. 

 

ANGLE 

MEAN CD/SQ M

 

45 

7192

 

55 

6459

 

65 

5333

 

75 

3973

 

85 

2101

**  Efficiency = 33.1%  **  SC = .7 

Certified Test Report No.18679FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**

  

  

     CEILING 

80% 

70% 

50% 

30%

        WALL  

 70   50   30   10 

  50   10 

 50   10 

 50   10 

  0 

RCR

 

.39  .39  .39  .39 

.37  .38 

.38  .38 

.35  .35 

.33

 

.38  .37  .37  .36 

.35  .37 

.37  .35 

.34  .33 

.32

 

.37  .35  .34  .33 

.33  .36 

.35  .33 

.33  .32 

.30

 

.35  .34  .33  .31 

.32  .35 

.33  .31 

.32  .30 

.29

 

.34  .32  .31  .30 

.30  .34 

.32  .30 

.31  .29 

.28

 

.33  .31  .30  .28 

.29  .33 

.31  .28 

.30  .28 

.27

 

.32  .30  .28  .27 

.28  .32 

.30  .27 

.29  .27 

.26

 

.31  .29  .27  .26 

.27  .31 

.29  .26 

.28  .26 

.25

 

.30  .28  .26  .25 

.26  .30 

.27  .25 

.27  .25 

.25

 

.29  .27  .25  .24 

.25  .29 

.27  .24 

.26  .24 

.24

 

10 

.28  .26  .24  .23 

.24  .28 

.26  .23 

.25  .23 

.23

 

 

 

 

LUMINAIRE INPUT WATTS = 44

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% 

70W T4.5 

Ceramic MH, 

Flood

 Upper Reflector, Philips, Lumen Rating = 6200 LMS., Aromat Electronic Ballast

750

1,500

2,250

3,000

30°

60°

  ANGLE 

MEAN CP 

LUMENS

 

3172 

 

3144 

303

 

10 

3054 

 

15 

2810 

763

 

20 

2215 

 

25 

1361 

618

 

30 

668 

 

35 

279 

194

 

40 

125 

 

45 

67 

57

 

50 

55 

 

55 

47 

42

 

60 

39 

 

65 

29 

29

 

70 

20 

 

75 

13 

14

 

80 

 

85 

3

 

90 

0

ZONAL LUMENS AND PERCENTAGES

  ZONE 

LUMENS  % LAMP  %LUMINAIRE

 

0-30 

1684 

27.16 

83.2

 

0-40 

1878 

30.29 

92.79

 

0-60 

1977 

31.9 

97.71

 

0-90 

2024 

32.65 

100

  40-90 

145 

2.35 

7.21

  60-90 

46 

0.75 

2.29

  90-180 

0

  0-180 

2024 

32.65 

100

LUMINANCE SUMMARY - CD. / SQ. M. 

 

ANGLE 

MEAN CD/SQ M

 

45 

13385

 

55 

11655

 

65 

9620

 

75 

7313

 

85 

4282

**  Efficiency = 32.6%  **  SC = .7 

Certified Test Report No.18755FR, Date: April 2, 2004. Computed by LSI Program **Test-Lite**

  

  

     CEILING 

80% 

70% 

50% 

30%

        WALL  

 70   50   30   10 

  50   10 

 50   10 

 50   10 

  0 

RCR

 

.39  .39  .39  .39 

.38  .38 

.36  .36 

.35  .35 

.33

 

.37  .37  .36  .35 

.36  .35 

.35  .34 

.33  .33 

.31

 

.36  .35  .34  .33 

.34  .32 

.33  .32 

.32  .31 

.30

 

.35  .33  .32  .31 

.33  .31 

.32  .30 

.31  .30 

.29

 

.34  .32  .30  .29 

.31  .29 

.31  .29 

.30  .29 

.28

 

.32  .30  .29  .28 

.30  .28 

.30  .28 

.29  .27 

.27

 

.31  .29  .28  .27 

.29  .27 

.29  .27 

.28  .26 

.26

 

.30  .28  .27  .26 

.28  .25 

.27  .25 

.27  .25 

.25

 

.29  .27  .26  .25 

.27  .24 

.27  .24 

.26  .24 

.24

 

.28  .26  .25  .24 

.26  .24 

.26  .23 

.25  .23 

.23

 

10 

.28  .25  .24  .23 

.25  .23 

.25  .23 

.25  .23 

.22

 

 

 

 

LUMINAIRE INPUT WATTS = 78

Coefficients of Utilization

Zonal Cavity Method - Effective Floor Cavity Reflectance = 20% 

Summary of Contents for Calculite C4T4GD-MHT4R

Page 1: ...tes mounting to virtually any ceiling system using pre installed mounting bars or 1 2 EMT tubing by others Single locking feature secures all adjustments Alignment holes and markings allow fixture to be pre set prior to installation Final adjustment can be made from below from inside fixture 7 Mounting Bars Galvanized steel 0 048 18 ga pre installed telescoping bars extend to 30 long and lock secu...

Page 2: ...36 39 36 38 36 38 36 35 8 41 38 36 35 38 35 37 35 37 35 34 9 40 37 36 34 37 34 37 34 36 34 34 10 39 36 35 34 36 34 36 34 36 33 33 LUMINAIRE INPUT WATTS 78 Coefficients of Utilization Zonal Cavity Method Effective Floor Cavity Reflectance 20 39W T4 5 Ceramic MH Flood Upper Reflector Philips Lumen Rating 3400 LMS Aromat Electronic Ballast 500 1000 1500 2000 500 1 000 1 500 2 000 30 60 ANGLE MEAN CP ...

Page 3: ...4 6 SC 6 Certified Test Report No 3937FR Date Oct 16 2008 Computed by LSI Program Test Lite Coefficients of Utilization Ceiling 80 70 50 30 Wall 70 50 30 10 50 10 50 10 50 10 0 RCR 0 74 74 74 74 72 72 69 69 66 66 62 1 72 71 70 69 70 68 67 66 65 64 61 2 70 68 67 66 67 65 65 63 64 62 60 3 68 66 65 63 65 63 64 62 63 61 59 4 67 65 63 61 64 61 63 60 62 60 58 5 66 63 61 60 62 59 61 59 61 58 57 6 65 62 6...

Page 4: ...ficiency 35 4 SC 5 Certified Test Report No 3948FR Date Oct 16 2008 Computed by LSI Program Test Lite Coefficients of Utilization Ceiling 80 70 50 30 Wall 70 50 30 10 50 10 50 10 50 10 0 RCR 0 68 68 68 68 66 66 63 63 60 60 57 1 66 65 64 63 64 62 61 60 59 59 56 2 64 63 61 60 62 59 60 58 58 57 55 3 63 61 59 58 60 57 59 57 57 56 54 4 61 59 57 56 59 56 58 55 56 55 53 5 60 58 56 54 57 54 56 54 55 53 52...