Job Information
Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609
Calculite
®
HID Lensed Downlight
C4T4GD-MHT4R
Page 4 of 4
4 1/2" Aperture, GU6.5 Glasslite
6000
4500
3000
1500
1500
3000
4500
6000
30°
60°
1000
750
500
250
250
500
750
1000
30°
60°
7500
2500
10000
5000
2500
5000
7500
10000
30°
60°
2250
750
3000
1500
750
1500
2250
3000
30°
60°
Angle
Mean CP
Lumens
0
5807
5
4630
419
10
2504
15
1091
364
20
457
25
143
92
30
52
35
26
19
40
17
45
14
11
50
11
55
8
7
60
5
65
4
3
70
2
75
1
1
80
0
85
0
0
90
0
Angle
Mean CP
Lumens
0
1085
5
1050
98
10
928
15
717
201
20
476
25
270
134
30
138
35
70
49
40
32
45
21
18
50
18
55
16
14
60
12
65
8
9
70
6
75
3
4
80
1
85
0
0
90
0
Angle
Mean CP
Lumens
0
10898
5
8996
814
10
5237
15
2194
732
20
704
25
222
144
30
99
35
66
44
40
46
45
36
29
50
32
55
27
23
60
17
65
10
10
70
4
75
1
2
80
0
85
0
0
90
0
Angle
Mean CP
Lumens
0
3100
5
3104
276
10
2277
15
1586
458
20
1011
25
570
283
30
292
35
146
102
40
67
45
43
37
50
38
55
31
28
60
24
65
15
16
70
9
75
3
4
80
1
85
1
0
90
0
Zonal Lumens and Percentages
Zone
Lumens
%Lamp
%Luminaire
0-30
875
54.23
95.48
0-40
894
55.41
97.55
0-60
912
56.52
99.5
0-90
917
56.8
100
40-90
22
1.39
2.45
60-90
4
0.28
0.5
90-180
0
0
0
0-180
917
56.8
100
Zonal Lumens and Percentages
Zone
Lumens
%Lamp
%Luminaire
0-30
432
26.8
82.25
0-40
481
29.82
91.51
0-60
513
31.8
97.6
0-90
526
32.58
100
40-90
44
2.77
8.49
60-90
12
0.78
2.4
90-180
0
0
0
0-180
526
32.58
100
Zonal Lumens and Percentages
Zone
Lumens
%Lamp
%Luminaire
0-30
1690
49.72
94.01
0-40
1734
51
96.44
0-60
1786
52.54
99.33
0-90
1798
52.89
100
40-90
64
1.88
3.56
60-90
11
0.35
0.67
90-180
0
0
0
0-180
1798
52.89
100
Zonal Lumens and Percentages
Zone
Lumens
%Lamp
%Luminaire
0-30
1017
29.92
84.46
0-40
1119
32.92
92.95
0-60
1184
34.83
98.33
0-90
1204
35.42
100
40-90
84
2.5
7.05
60-90
20
0.59
1.67
90-180
0
0
0
0-180
1204
35.42
100
Luminance Summary
Angle
Mean CD/SQ M
45
1985
55
1336
65
868
75
398
85
0
Luminance Summary
Angle
Mean CD/SQ M
45
2918
55
2750
65
1957
75
1315
85
44
Luminance Summary
Angle
Mean CD/SQ M
45
5009
55
4601
65
2300
75
402
85
0
Luminance Summary
Angle
Mean CD/SQ M
45
5891
55
5361
65
3434
75
1086
85
592
** Efficiency = 56.8% ** SC = .3 Certified Test Report No. 3955FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
** Efficiency = 32.6% ** SC = .6 Certified Test Report No. 3954FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
** Efficiency = 52.9% ** SC = .3 Certified Test Report No. 3947FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
** Efficiency = 35.4% ** SC = .5 Certified Test Report No. 3948FR, Date: Oct 16, 2008. Computed by LSI Program **Test-Lite**
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
Wall 70 50 30 10
50 10
50 10
50 10
0
RCR
0 .68 .68 .68 .68
.66 .66
.63 .63
.60 .60
.57
1 .66 .65 .64 .63
.64 .62
.61 .60
.59 .59
.56
2 .64 .63 .61 .60
.62 .59
.60 .58
.58 .57
.55
3 .63 .61 .59 .58
.60 .57
.59 .57
.57 .56
.54
4 .61 .59 .57 .56
.59 .56
.58 .55
.56 .55
.53
5 .60 .58 .56 .54
.57 .54
.56 .54
.55 .53
.52
6 .59 .57 .55 .53
.56 .53
.55 .53
.55 .53
.52
7 .58 .55 .54 .52
.55 .52
.54 .52
.54 .52
.51
8 .57 .54 .52 .51
.54 .51
.53 .51
.53 .51
.50
9 .56 .53 .52 .50
.53 .50
.53 .50
.52 .50
.49
10 .55 .52 .51 .49
.52 .49
.52 .49
.52 .49
.49
Luminaire Input Watts = 25
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
Wall 70 50 30 10
50 10
50 10
50 10
0
RCR
0 .39 .39 .39 .39
.38 .38
.36 .36
.35 .35
.33
1 .37 .37 .36 .36
.36 .35
.35 .34
.34 .33
.31
2 .36 .35 .34 .33
.34 .33
.33 .32
.32 .31
.30
3 .35 .33 .32 .31
.33 .31
.32 .30
.31 .30
.29
4 .34 .32 .31 .30
.32 .29
.31 .29
.30 .29
.28
5 .33 .31 .29 .28
.30 .28
.30 .28
.29 .27
.27
6 .32 .29 .28 .27
.29 .27
.29 .27
.28 .26
.26
7 .30 .28 .27 .26
.28 .26
.28 .26
.27 .25
.25
8 .30 .27 .26 .25
.27 .25
.27 .25
.26 .24
.24
9 .29 .26 .25 .24
.26 .24
.26 .24
.26 .24
.23
10 .28 .25 .24 .23
.25 .23
.25 .23
.25 .23
.22
Luminaire Input Watts = 25
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
Wall 70 50 30 10
50 10
50 10
50 10
0
RCR
0 .63 .63 .63 .63
.61 .61
.59 .59
.56 .56
.53
1 .61 .60 .59 .59
.59 .58
.57 .56
.55 .54
.52
2 .60 .58 .57 .56
.57 .55
.55 .54
.54 .53
.51
3 .58 .56 .55 .53
.56 .53
.54 .52
.53 .52
.50
4 .57 .55 .53 .52
.54 .51
.53 .51
.52 .50
.49
5 .56 .53 .51 .50
.53 .50
.52 .50
.51 .49
.48
6 .55 .52 .50 .49
.52 .49
.51 .49
.51 .49
.48
7 .54 .51 .49 .48
.51 .48
.50 .48
.50 .48
.47
8 .53 .50 .48 .47
.50 .47
.49 .47
.49 .47
.46
9 .52 .49 .48 .46
.49 .46
.49 .46
.48 .46
.46
10 .51 .48 .47 .46
.48 .46
.48 .45
.48 .45
.45
Luminaire Input Watts = 45
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Coefficients of Utilization
Ceiling
80%
70%
50%
30%
Wall 70 50 30 10
50 10
50 10
50 10
0
RCR
0 .42 .42 .42 .42
.41 .41
.39 .39
.38 .38
.35
1 .41 .40 .39 .39
.39 .38
.38 .37
.37 .36
.34
2 .39 .38 .37 .36
.37 .36
.36 .35
.35 .34
.33
3 .38 .36 .35 .34
.36 .34
.35 .33
.34 .33
.32
4 .37 .35 .34 .33
.35 .32
.34 .32
.33 .32
.31
5 .36 .34 .32 .31
.33 .31
.33 .31
.32 .30
.30
6 .35 .32 .31 .30
.32 .30
.32 .30
.31 .29
.29
7 .34 .31 .30 .29
.31 .29
.31 .29
.30 .28
.28
8 .33 .30 .29 .28
.30 .28
.30 .28
.29 .27
.27
9 .32 .29 .28 .27
.29 .27
.29 .27
.29 .26
.26
10 .31 .28 .27 .26
.28 .26
.28 .26
.28 .26
.25
Luminaire Input Watts = 45
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
20W GU6.5
GE Constantcolor CMH Lamp,
Narrow Flood
Upper Reflector, Lumen Rating = 1615 lms, Aromat Electronic Ballast
20W GU6.5
GE Constantcolor CMH Lamp,
Flood
Upper Reflector, Lumen Rating = 1615 lms, Aromat Electronic Ballast
39W GU6.5
GE Constantcolor CMH Lamp,
Narrow Flood
Upper Reflector, Lumen Rating = 3400 lms, Aromat Electronic Ballast
39W GU6.5
GE Constantcolor CMH Lamp,
Flood
Upper Reflector, Lumen Rating = 3400 lms, Aromat Electronic Ballast