background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • B0609

Job Information 

Type:

Job Name: 

Cat. No.: 

Lamp(s): 

Notes:

Calculite

®

 HID Lensed Downlight

  C4T4GD-MHT4R

Page 1 of 4 

4 1/2" Aperture, T4 Ceramic Metal Halide, Glasslite

For complete fixture order: Trim Kit (Glasslite) + Upper Ref Frame-In Kit. Sold Separately

Glasslite Trim Kit + Upper Reflector

Frame-In Kit

Lamping 

(Ceramic Metal Halide)

 MHT4RS

 (Spot Upper Reflector)

MHT4RNF

 (Narrow Flood Upper Reflector)

MHT4RF

 (Flood Upper Reflector)

C4A20BT5PGJ5E1
C4A20T4GU65EU
C4A20T4EU
C4A39T4GU65EU
C4A39T4E1
C4A39T4E2
C4A70T4E1
C4A70T4E2

Electronic 120V
Electronic 120V/277V
Electronic 120V/277V
Electronic 120V/277V
Electronic 120V
Electronic 277V
Electronic 120V
Electronic 277V

22W Philips MiniMasterColor
20W GE ConstantColor
20W T4.5
39W Philips MiniMasterColor
39W T4.5
39W T4.5
70W T4.5
70W T4.5

Features

1.  Upper Reflector: 

Specular faceted aluminum; select 12° Spot (MHT4RS) 25° 

Narrow Flood (MHT4RNF) or 40° Flood (MHT4RF); interchangeable.

2.  Glasslite Trim Kit: 

One piece borosilicate etched glass. 

3.  Lamp Holder: 

Unitized construction assures proper alignment of lamp to 

optics for consistent optical performance.

4.  Socket Housing:

 Galvanized steel, pre-wired with G8.5 pulse rated 

socket. Snaps onto yoke for secure attachment without tools; unitized 
construction assures proper alignment of lamp to optics for consistent optical 
performance.

5.  Frame Housing:

 Steel, 0.029" (22-Ga.), matte black finish. Removable cover 

for top re-lamping.

6.  Frame Vertical Adjustment Mechanism:

 Accommodates mounting to 

virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT 
tubing (by others). Single locking feature secures all adjustments. Alignment 
holes and markings allow fixture to be pre-set prior to installation. Final 
adjustment can be made from below from inside fixture. 

7.  Mounting Bars: 

Galvanized steel, 0.048" (18-ga.), pre-installed telescoping 

bars extend to 30" long and lock securely into position. Built-in locking tabs 
provide positive attachment to common T-bar systems. Self-centering feature 
simplifies installation in 24" O.C. grid systems. Attaches to steel or wood 
joists without accessories.

8.  Retention Springs:

 Rust resistant springs secure trim for quick, tool-less 

installation.

9.  Ballast / Cover Assembly: 

Accessible from below and removable without 

tools for inspection and ballast replacement .

10. Junction Box: 

0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 

90° C through branch circuit conductors. Allows inspection from below. 

11. Optional Accessory Holder:

 Catalog # CAH4 Sold separately; die-formed 

steel, matte black finish, slide-in installation. Accepts up to two 3 3/4" dia. 
media.

Features 

(continued)

12. Thermal Protector:

 (Not Shown) Meets NEC and UL requirements. Do not 

install insulation above nor within 3" (76mm) of any part of the luminaire.

Electrical

Electronic Ballast:

 120V or 277V, 50/60 Hz., encased, high power factor, T.H.D. 

<15%, thermally and transient protected, RMI/RFI complies with FCC Part 18 
non-consumer limits, shut-down circuit at end of lamp life, sound rating “A”, 
-5° F minimum starting temperature, Type 1 Outdoor rating.

  Ballast 

ANSI Code  Voltage  Max. Amps  Input Watts

  20W MH  M156 

120/277 

0.21/0.10 

23

  39W MH  M130 

120/277 

0.39/0.17  

44

  70W MH  M139 

120/277 

0.67/0.29  

78

Options and Accessories

Chicago Plenum:

 Consult Factory.

Labels

UL (Suitable for Wet Locations), CSA, I.B.E.W.

Ceiling Cutout: 

5 1/8” (130 mm) Dia.

Summary of Contents for Calculite C4T4GD-MHT4R

Page 1: ...tes mounting to virtually any ceiling system using pre installed mounting bars or 1 2 EMT tubing by others Single locking feature secures all adjustments Alignment holes and markings allow fixture to be pre set prior to installation Final adjustment can be made from below from inside fixture 7 Mounting Bars Galvanized steel 0 048 18 ga pre installed telescoping bars extend to 30 long and lock secu...

Page 2: ...36 39 36 38 36 38 36 35 8 41 38 36 35 38 35 37 35 37 35 34 9 40 37 36 34 37 34 37 34 36 34 34 10 39 36 35 34 36 34 36 34 36 33 33 LUMINAIRE INPUT WATTS 78 Coefficients of Utilization Zonal Cavity Method Effective Floor Cavity Reflectance 20 39W T4 5 Ceramic MH Flood Upper Reflector Philips Lumen Rating 3400 LMS Aromat Electronic Ballast 500 1000 1500 2000 500 1 000 1 500 2 000 30 60 ANGLE MEAN CP ...

Page 3: ...4 6 SC 6 Certified Test Report No 3937FR Date Oct 16 2008 Computed by LSI Program Test Lite Coefficients of Utilization Ceiling 80 70 50 30 Wall 70 50 30 10 50 10 50 10 50 10 0 RCR 0 74 74 74 74 72 72 69 69 66 66 62 1 72 71 70 69 70 68 67 66 65 64 61 2 70 68 67 66 67 65 65 63 64 62 60 3 68 66 65 63 65 63 64 62 63 61 59 4 67 65 63 61 64 61 63 60 62 60 58 5 66 63 61 60 62 59 61 59 61 58 57 6 65 62 6...

Page 4: ...ficiency 35 4 SC 5 Certified Test Report No 3948FR Date Oct 16 2008 Computed by LSI Program Test Lite Coefficients of Utilization Ceiling 80 70 50 30 Wall 70 50 30 10 50 10 50 10 50 10 0 RCR 0 68 68 68 68 66 66 63 63 60 60 57 1 66 65 64 63 64 62 61 60 59 59 56 2 64 63 61 60 62 59 60 58 58 57 55 3 63 61 59 58 60 57 59 57 57 56 54 4 61 59 57 56 59 56 58 55 56 55 53 5 60 58 56 54 57 54 56 54 55 53 52...