13. DDC Instruction
General
DDC Data Re-programming
In case the main EEPROM with Software DDC which store all factory settings were replaced because a defect,
repaired monitor’ the serial numbers have to be re-programmed.
It is advised to re- soldered the main EEPROM with Software DDC from the old board onto the new board if circuit
board have been replaced, in this case the DDC data does not need to be re-programmed.
Additional information about DDC (Display Data Channel) may be obtained from Video Electronics Standards
Association (VESA). Extended Display Identification Data (EDID) information may be also obtained from VESA.
1. An i486 (or above) personal computer or compatible.
2. Microsoft operation system Windows 95/98/2000/XP.
3. “PORT95NT.exe, WinDDC.exe” program.
4. Software SN Alignment kits
The kit contents:
a. DDC Board x1(715GT034-B)
b. Printer cablex1
c. VGA cable x 1
d. 12V DC power source
e. Power cord
Note: The DDC instruction for 191V2&221V2 is the same with 241E1, so take the 241E1 for example.
13.1. Install the “PORT95NT.EXE”, and restart the computer.
13.2 Connect the DDC Board as follow:
AC 220V
PC LPT
Printer Cable
Power Cord
715LT035-A
12VDC
VGA Cable
715GT034-B
Summary of Contents for C221V2SB/01
Page 37: ...37 Meridian 2 ...
Page 48: ...48 Meridian 2 Step 5 Remove the AC SHIELD VGA DVI and PANEL 191V2 221V2 FFC cable ...
Page 50: ...50 Meridian 2 Step 7 Remove the WIRES as marked ...
Page 51: ...Meridian 2 51 ...
Page 59: ...Meridian 2 59 d Click icon e Successfully if the graphic is show as below ...
Page 61: ...Meridian 2 61 Take analog DDC write for example as follow a Double click appear as follow ...