background image

Philips Semiconductors

Product specification

 TOPFET high side switch

BUK214-50Y 

 SMD version of BUK209-50Y

 

OVERLOAD PROTECTION CHARACTERISTICS

5.5 V 

 V

BG

 

 35 V, limits are at -40˚C 

 T

mb

 

 150˚C and typicals at T

mb

 = 25 ˚C unless otherwise stated.

Refer to 

TRUTH TABLE

.

SYMBOL

PARAMETER

CONDITIONS

MIN.

TYP.

MAX.

UNIT

Overload protection

V

BL

 = V

BG

I

L(lim)

Load current limiting

V

BG

 

 9 V

20

30

40

A

Short circuit load protection

V

BL(TO)

Battery load threshold voltage

1

V

BG

 = 16 V

8

10

12

V

V

BG

 = 35 V

15

20

25

V

t

d sc

Response time

2

V

BL

 > V

BL(TO)

-

180

250

µ

s

Overtemperature protection

T

j(TO)

Threshold junction

150

170

190

˚C

temperature

3

T

j(TO)

Hysteresis

-

10

-

˚C

SWITCHING CHARACTERISTICS

T

mb

 = 25 ˚C, V

BG

 = 13 V, for resistive load R

L

 = 13 

.

SYMBOL

PARAMETER

CONDITIONS

MIN.

TYP.

MAX.

UNIT

During turn-on

from input going high

t

d on

Delay time

to 10% V

L

-

45

70

µ

s

dV/dt

on

Rate of rise of load voltage

30% to 70% V

L

-

0.4

1.0

V/

µ

s

on

Total switching time

to 90% V

L

-

110

180

µ

s

During turn-off

from input going low

t

d off

Delay time

to 90% V

L

-

50

80

µ

s

dV/dt

off

Rate of fall of load voltage

70% to 30% V

L

-

0.7

1.1

V/

µ

s

off

Total switching time

to 10% V

L

-

75

120

µ

s

CAPACITANCES

T

mb

 = 25 ˚C; f = 1 MHz; V

IG

 = 0 V.  designed in parameters.

SYMBOL

PARAMETER

CONDITIONS

MIN.

TYP.

MAX.

UNIT

C

ig

Input capacitance

V

BG

 = 13 V

-

15

20

pF

C

bl

Output capacitance

V

BL

 = 13 V

-

200

300

pF

C

sg

Status capacitance

V

SG

 = 5 V

-

11

15

pF

The battery to load threshold voltage for short circuit protection is proportional to the battery supply voltage.  A graph showing V

BL(TO)

 versus

V

BG

 will be provided in the product specification.  After short circuit protection has operated, the input voltage must be toggled low for the

switch to resume normal operation.

Measured from when the input goes high.

After cooling below the reset temperature the switch will resume normal operation.

September 2002

6

Rev 2.000

Summary of Contents for BUK209-50Y

Page 1: ... FUNCTIONAL BLOCK DIAGRAM Vertical power TrenchMOS Low on state resistance CMOS logic compatible Very low quiescent current Overtemperature protection Load current limiting Latched overload and short circuit protection Overvoltage and undervoltage shutdown with hysteresis On state open circuit load detection Diagnostic status indication Voltage clamping for turn off of inductive loads ESD protecti...

Page 2: ...clamping IL 5 A EBL Non repetitive clamping energy Tj 150 C prior to turn off 100 mJ ESD LIMITING VALUE SYMBOL PARAMETER CONDITIONS MIN MAX UNIT VC Electrostatic discharge capacitor Human body model 2 kV voltage C 250 pF R 1 5 kΩ THERMAL CHARACTERISTICS SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNIT Thermal resistance4 Rth j mb Junction to mounting base 1 8 2 2 K W 1 For normal continuous operation ...

Page 3: ... 7 Tmb RON On state resistance 9 to 35 V 5 A 300 µs 25 C 45 60 mΩ 150 C 120 mΩ RON On state resistance 6 V 5 A 300 µs 25 C 55 75 mΩ 150 C 150 mΩ RG Internal ground resistance IG 10 mA 95 150 190 Ω 1 For a high side switch the load pin voltage goes negative with respect to ground during the turn off of an inductive load 2 On state resistance is increased if the supply voltage is less than 9 V Refer...

Page 4: ...b 25 C unless otherwise stated Refer to TRUTH TABLE SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNIT VSG Status clamping voltage IS 100 µA 5 5 7 8 5 V VSG Status low voltage IS 100 µA 1 V Tmb 25 C 0 7 0 8 V IS Status leakage current VSG 5 V 15 µA Tmb 25 C 0 1 1 µA IS Status saturation current1 VSG 5 V 2 7 12 mA Application information RS External pull up resistor 47 kΩ OPEN CIRCUIT DETECTION CHARACTER...

Page 5: ... H off H 0 0 0 0 0 ON H on normal H 0 0 1 0 0 ON L on low current detect H 1 0 X X X OFF H supply undervoltage lockout H 0 1 X 0 0 OFF H supply overvoltage shutdown H 0 0 0 1 X OFF L SC tripped H 0 0 0 0 1 OFF L OT shutdown3 KEY TO ABBREVIATIONS L logic low UV undervoltage H logic high OV overvoltage X don t care LC low current or open circuit load 0 condition not present SC short circuit 1 condit...

Page 6: ...10 VL 45 70 µs dV dton Rate of rise of load voltage 30 to 70 VL 0 4 1 0 V µs t on Total switching time to 90 VL 110 180 µs During turn off from input going low td off Delay time to 90 VL 50 80 µs dV dtoff Rate of fall of load voltage 70 to 30 VL 0 7 1 1 V µs t off Total switching time to 10 VL 75 120 µs CAPACITANCES Tmb 25 C f 1 MHz VIG 0 V designed in parameters SYMBOL PARAMETER CONDITIONS MIN TY...

Page 7: ...single ended surface mounted package Philips version of D2 PAK 5 leads one lead cropped SOT426 e e e e E b A1 A A1 Lp b c D max e A UNIT DIMENSIONS mm are the original dimensions E 11 mm 4 50 4 10 1 40 1 27 0 85 0 60 0 64 0 46 2 90 2 10 HD 15 80 14 80 Q 2 60 2 20 10 30 9 70 D1 1 60 1 20 1 70 98 12 14 99 06 25 1 3 2 4 5 mounting base D1 HD D Q Lp c 1 Epoxy meets UL94 V0 at 1 8 Net mass 1 5 g For so...

Page 8: ...en in the Characteristics sections of this specification is not implied Exposure to limiting values for extended periods may affect device reliability Application information Where application information is given it is advisory and does not form part of the specification Philips Electronics N V 2002 All rights are reserved Reproduction in whole or in part is prohibited without the prior written c...

Reviews: