86BDL6051C
35
•
{On}
-
Enable the function.
•
{Off}
-
Disable the function and Audio Out Volume will
be grayed out.
Speaker Setting
Enable/disable speaker.
NOTE:
This function is available only when “Audio Out
Sync” is on.
6.2.4. Configuration menu
Switch on state
Select the display status that will be applied when you
connect the power cord next time.
•
{Power off}
- The display will remain off when the power
cord is connected to a wall outlet.
•
{Forced on}
- The display will turn on when the power
cord is connected to a wall outlet.
•
{Last status}
- The display will return to the previous
power status (on/off/standby) when removing and
replacing the power cord.
Panel saving
Choose to enable the panel saving functions and thus
reduce the risk of image persistence or ghost imaging.
•
{Brightness}
- Select {
On
} and the image brightness will
be reduced to 30%.
•
{Pixel shift}
- Select the time interval (
{Auto}
/
{10
~
900}
seconds ) for the display to slightly expand the image
size and shift the position of pixels in four directions (up,
down, left, or right). Activating Pixel Shift will disable H
Position, V Position and Zoom Mode in the screen menu.
NOTES:
•
Auto is 60 seconds.
•
Only supports external input source (HDMI, VGA, DP,
OPS, DVI)
RS232 routing
Select the network control port.
Choose from:
{RS232}
/
{LAN->RS232}
/
{OPS RS232 (OPS
model only)}
/
{STANDALONE}
.
Boot on source
Choose to select source when booting up.
Last Input : keep last input when booting up.
Input: select input source(follow S12 Input source) when
booting up.
Playlist: select playlist index for Media player, Browser.
0: No playlist. Same as switching source from OSD.
1
~
7: playlist number.
8: MediaPlayer autoplay.
No failover function, sysytem will keep source even the
source has no signal input.
WOL
Choose to turn on or off the wake on LAN function.
Choose from :
{Off}
/
{On}
.
DP Version
Change DP version. 1.1 or 1.2.
HDMI Version
Change HDMI version. 1.4 or 2.0.
Information OSD
Set the period of time the information OSD display on the
screen. The options are {Off, 1-60} seconds.
Monitor ID
Set the ID number for controlling the display via the RS232C
connection.
Each display must have a unique ID number when multiple
sets of the display are connected. Monitor ID number range
is between 1 to 255.
The option are:
{Monitor group}
.
Monitor ID
Monitor ID
Monitor group
1
1
•
{Monitor group}
The option are:
{Off}
/
{1-254}
•
{Off}
–
{Monitor group}
are not supported.
•
{1-254}
–
{Monitor group}
are supported. The default
setting is 1.
1
2
5
6
3
4
7
8
9
10
11
12
13
14
15
16
Heat status
This function allows you to check the thermal status and fan
speed of the display.
63°C
65°C
76°C
78°C
FAN
X
V
V
V
Warning MSG
X
X
V
X
PD Power Off
X
X
X
V