Service Modes, Error Codes, and Fault Finding
EN 13
LGE PDP 2K6
5.
5.1.1
No Display
Check each section with following method.
If there is a problem, replace or repair that part.
If it is not found, go to the next section.
Connectors
Check all connectors (PSU, Y-SUS, CTRL, Z-SUS). The
module may not function normally by a misconnection (can not
send signal and/or power). Also misconnection for a long
period can cause a specific board to fail.
Figure 5-3 C Y-SUS board
Figure 5-4 C Z-SUS board
Figure 5-5 C X board
Figure 5-6 Signal input (LVDS)
Exhaust Tip
Check the Exhaust Tip for cracks with the naked eye to check
the vacuum state.
If there is a problem, replace the PDP module by a new one.
In case of vacuum breakdown, the module makes a shaking
noise because of inside gas ventilation.
There may be a small crack, which cannot be seen with the
naked eye. This noise is different from capacitor noise.
Figure 5-7 Exhaust tip "normal"