Mechanical instructions
GB 9
FTV1.9DE
4.
1.
Some testpoints are accessible at the B-side [1].
2.
If this is not sufficient, remove the 3 fixation screws of the
panel [2].
3.
Panel now can be hinged on the left side to access the A-
side (soldering side) [3].
4.1.4
PRECONDITIONER panel.
Figure 4-5
1.
Disconnect the 2 grounding wires from the shielding plate
by pressing the small lever on the connector while pulling
[1].
2.
Remove the 2 ferrite ring cores from their fixations [2].
3.
Remove the 5 fixation screws of the panel [3].
4.
Place panel on the 2 hinges, which are located, near the
left corners of the panel [4].
5.
Reconnect grounding wires to the extra connectors on the
shielding plate at the left side [5].
6.
The copperside becomes accessible now from the right
side.
4.1.5
AUDIO VIDEO CONTROL panel.
Figure 4-6
This panel has no service position for accessing the A-side,
however all service test points are accessible at the B-side (see
Service Manual).
In case some components must be (de)soldered, all fixation
screws (6 for the panel, 5 at the metal connector plate) and all
cables must be removed to access the A-side.
4.1.6
PDP LIMESCO panel.
Figure 4-7
All SMC's are located on the B-side, so all testpoints are
accessible. In case some components must be (de)soldered,
the hinge construction can be used to access the A-side.
1.
Remove the 4 fixation screws of the panel [1].
2.
Panel can now be hinged to access soldering side [2].
4.1.7
YUV/YC INPUT panel.
Figure 4-8
This panel has no pre-defined service position. For access of
the A-side, the panel has to be removed:
1.
Remove the 4 screws at the metal connector plate [1].
2.
Remove the 2 fixation screws of the panel [2].
3.
Panel can be removed now to access the A-side [3].
5
CL 96532069_135.EPS
120899
1
1
2 2
3
5
5
4
4
Pre-conditioner
CL 96532069_136.EPS
120899
AV Control
CL 96532069_137.EPS
120899
1
1
1
1
2
PDP Limesco
YUV/YC Input
2
1
3
CL 96532069_138.EPS
120899
SVHS
BNC
2