x
Truck shipment-
Transportation request for all regions except China/India
A. Air shipment 1134*1180/1134*1050
B. 20’/40’/40’HQ Container loading for WW 704/1456/1820
Transportation request for China and India
A. Container loading for China and India 640/1312/1312
B. Truck
loading
Transportation request for EU
A. Land 45‘ Truck and Trailer (800X1200mm pallet) 1584
C. Land 45‘ Truck and Trailer (1000X1200mm pallet) for UK 1456
ENVIRONMENTAL CHARACTERISTICS
The following sections define the interference and
susceptibility condition limits that might occur
between external environment and the display device.
Susceptibility of display to external environment
Operating
- Temperature : 0 to 35 degree C
- Humidity : 80% max
- Altitude : 0-3658m
- Air pressure : 600-1100 mBAR
Storage
- Temperature : -20 to 60 degree C
- Humidity : 95% max
- Altitude : 0-12192m
- Air pressure : 300-1100 mBAR
Note: recommend at 5 to 35
q
C, Humidity less than 60 %
Transportation tests
Refer to 5.15.2
Display disturbances from external environment
According to IEC 801-2 for ESD disturbances
Display disturbances to external environment
RELIABILITY
Mean Time Between Failures
System MTBF (Including the LCD panel and CCFL) : 50,000 hrs
QUALITY ASSURANCE REQUIREMENTS
Acceptance test
According to MIL-STD-1916D Control III level
AQL: NA
(Please also refer to annual quality agreement)
Customer acceptance criteria: UAW0377/00
Summary of Contents for 273E3LSW/93
Page 5: ... 5 Meridian 3 1 Monitor Specifications Technical specifications ...
Page 30: ... 30 Meridian 3 9 Scaler Board Overview FFC Cable D SUB EEPROM DVI EEPROM DC DC Scaler IC ...
Page 38: ... 38 Meridian 3 Click Finish to complete the USB serial port driver installation ...
Page 41: ...41 Meridian 3 7 Start to program Click Auto to start programming ...
Page 47: ...47 Meridian 3 3 Select the EDID folder Select correct folder ...