44 Meridian 3
11. Repair Flow Chart
1. No Power
OK
NG
No power
Check power cable is
tightened?
Check Power “On/Off”
is “On”?
Re-plug the power cable
Replace main board and check connections
Check the LED
indicator is OK?
Check the AC power
Replace the power board and check connections
OK
NG
OK
NG
NG
Turn on the Power “On/Off” switch
Replace key board and check connections
NG