89
Meridian 3
6. Environmental Characteristics
The following sections define the interference and susceptibility condition limits that might occur between
external environment and the display device.
6.1 Susceptibility of display to external environment
Operating
- Temperature:
0 to 40 degree C
-
Humidity:
80%
max
-
Altitude:
0
-3658
ft
- Air pressure:
600-1100 mBAR
Storage
- Temperature:
-20 to 60 degree C
-
Humidity:
95%
max
- Altitude:
0 -12192ft
- Air pressure:
300-1100 mBAR
Note
: recommend at 5 to 35
q
C, Humidity less than 60%.
6.2 Transportation tests
Refer to 5.15.2
6.3 Display disturbances from external environment
According to IEC 801-2 for ESD disturbances
6.4 Display disturbances to external environment
7. Reliability
7.1 Mean Time between Failures
System MTBF (Including the LCD panel and CCFL): 50,000 hrs
8. Quality Assurance Requirements
8.1 Acceptance test
According to MIL-STD-1916D Control II level
AQL: NA
(Please also refer to annual quality agreement)
Customer acceptance criteria: UAW0377/00
9. Philips’ Flat Panel Monitors Pixel Defect Policy
Philips’ Flat Panel Monitors Pixel Defect Policy
Bright Dot Defects
Acceptable Level
MODEL
221P3
1 lit sub-pixel
3
2 adjacent lit sub-pixels
1