60 Meridian 3
5. Color Temp confirmation
Connect the signal to the monitor, the monitor displays white-picture, use CA-210 to measure the Color Temp of the
screen center and select the OSD to make sure whether the Color Temps accord with the SPEC.
CIE coordinates
9300K
6500K/sRGB
sRGB
x 0.283±0.02
0.313±0.02
0.313±0.02
y 0.297±0.02
0.329±0.02
0.329±0.02
6. How to enter into the factory mode:
1. Connect the video source and power off the monitor.
2. Press
and
buttons at the same time, power on the monitor, and then press the menu again; the
picture will appear on the top left corner.
3. Select the “Factory” and press the “MENU” button to enter the factory mode.