background image

OEM Catalogue 2009/2010

3.94

HPL Comfort

Performance diagram

%

t

0

40

80

120

160

200

10

2

4

6

8

I

la

W

la

V

la

HPL

Lamp performance during run up

Lumen maintenance diagram

50

60

70

80

90

100

16000

Lumen in 

%

Burning hours

4000

12000

0

8000

20000

HPL 50W/80W/125W/250W/400W

Life expectancy diagram

50

60

70

80

90

100

16000

Survivals in 

%

Burning hours

4000

12000

0

8000

20000

HPL 50W/80W/125W/250W/400W

Photometric diagram

180

°

150

°

210

°

0

°

30

°

330

°

60

°

90

°

120

°

300

°

270

°

240

°

180

°

150

°

210

°

0

°

30

°

330

°

60

°

90

°

120

°

300

°

270

°

240

°

100

50

50

100

HPL Comfort 250W

Cap Base

27

E27

40

E40

Operating position

any

Summary of Contents for 220-230-240V

Page 1: ...HID Lamps and Gear ...

Page 2: ...3 2 OEM Catalogue 2009 2010 ...

Page 3: ...e and energy efficiency and every lamp must have a long lifetime Reliability is essential as traffic congestion during spot replacement of premature failures can be very expensive The recommended HID families that anticipate upon these lamp specifications are MASTER SON PIA MASTER SOX and Ceramic Metal Halide Urban lighting Covers streets parks and squares shopping and leisure areas in city center...

Page 4: ...3 4 OEM Catalogue 2009 2010 ...

Page 5: ... to avoid glare and light spill professional sports lighting must cater for the needs of colour TV coverage and photography This requires extremely high light levels three times those used in commercial offices and superb colour rendering Because of the limited burning period lamp lifetime is a less important consideration than reliability Dedicated lamps for these applications are the MASTER MHN ...

Page 6: ...ystems with high precision optics for good beam control and minimal spill light Very good colour rendering creates a pleasant ambience with high visual comfort for players and spectators Continuous spectral distribution offers a superior solution for semi professional stadiums with regular TV coverage Application Professional sports lighting and floodlighting Luminaires MHN SA lamps require UV abs...

Page 7: ...60 p15 MASTER MHN SA 1800W 956 230V XW P SFC UNP 155000 86 Daylight 5600 90 330 339 p15 MASTER MHN SA 1800W 956 P SFC 400V UNP 160000 86 Daylight 5600 90 330 339 p15 MASTER MHN SA 2000W 956 400V XW UNP 200000 98 Daylight 5600 90 330 362 p15 Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTER MHN SA 1800W 856...

Page 8: ...V 4 8 12 16 20 400 500 600 700 nm W nm MHN SA 2000W 956 400V Performance diagram t 0 40 80 120 160 200 5 1 2 3 4 Ila Wla Vla MHN SA Lamp performance during run up Lumen maintenance diagram 50 60 70 80 90 100 4000 Lumen in Burning hours 1000 3000 0 2000 5000 MHN SA 1800W 856 956 230V 400V 50 60 70 80 90 100 4000 Lumen in Burning hours 1000 3000 0 2000 5000 MHN SA 2000W 956 400V ...

Page 9: ...gram 50 60 70 80 90 100 4000 Survivals in Burning hours 1000 3000 0 2000 5000 MHN SA 1800W 856 956 230V 400V MASTER MHN SA 50 60 70 80 90 100 4000 Survivals in Burning hours 1000 3000 0 2000 5000 MHN SA 2000W 956 400V Cap Base 18 P SFC Operating position p15 ...

Page 10: ...ll light Good colour rendering creates a pleasant ambience with high visual comfort for players and spectators Continuous spectral distribution offers options for semi professional stadiums and for professional stadiums with regular TV coverage Application Professional and semi professional sports lighting and floodlighting Luminaires MHN LA lamps require UV absorbing and protective front glass an...

Page 11: ...UNP 90000 86 5 Daylight 5600 90 330 339 p5 MASTER MHN LA 2000W 842 400V XWH UNP 220000 108 Cool White 4200 80 370 370 p5 MASTER MHN LA 2000W 956 400V XWH UNP 190000 93 Daylight 5600 90 330 339 p5 Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTER MHN LA 1000W 842 230V XWH UNP MN 1000 E K H 8711500200785 0 1...

Page 12: ...run up Lumen maintenance diagram 50 60 70 80 90 100 8000 Lumen in Burning hours 2000 6000 0 4000 10000 MHN LA 1000W 842 956 230V 50 60 70 80 90 100 Lumen in Burning hours 3000 9000 0 6000 12000 MHN LA 2000W 842 956 400V Life expectancy diagram 50 60 70 80 90 100 8000 Survivals in Burning hours 2000 6000 0 4000 10000 MHN LA 1000W 842 956 230V 50 60 70 80 90 100 Survivals in Burning hours 3000 9000 ...

Page 13: ...OEM Catalogue 2009 2010 3 13 HID Lamps MASTER MHN LA ...

Page 14: ... Allows compact and efficient luminaire systems with precision optics for good beam control and minimal light spill Long lifetime and high reliability in Short Base outer dimensions to minimise service needs and maintenance costs Good colour rendering for a pleasant ambience with high visual comfort Application Semi professional sports area and floodlighting Luminaires Requires UV absorbing and pr...

Page 15: ...ight 5600 90 325 355 p15 Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MHN SB 2000W 956 400V K12s 7 WH UNP MN 2000 E Cable H 8711500206732 0 08 kg 8711500206732 43 cm x 9 5 cm x 8 5 cm 8711500206732 206732 00 Spectral power distribution 4 8 12 16 20 400 500 600 700 nm W nm MHN SB 2000W 956 Performance diagram...

Page 16: ...rs a natural white colour appearance and good colour stability Product Benefits High safety and comfort level maintained over life Minimal maintenance cost Application Sports lighting floodlighting of buildings and monuments area lighting e g harbours and building sites Luminaires HPI T lamps require a protective front glass Recommended gear page 3 170 www philips com OEM D L C O HPI T 1000W Type ...

Page 17: ...olour Designation Colour Temperature K Colour Rendering Index Ra Chromaticity Coordinate X Chromaticity CoordinateY Operating Position HPI T 1000W 643 E40 220V CRP 85000 86 Cool White 4300 65 370 380 p20 HPI T 2000W 642 E40 380V CRP 210000 107 Cool White 3800 65 397 403 p20 HPI T 2000W 646 E40 220V CRP 189000 96 Cool White 4200 65 375 385 p75 Ordering and packing data Type ILCOS EAN code 1 piece W...

Page 18: ... 100 8000 Lumen in Burning hours 2000 6000 0 4000 10000 HPI T 1000W 2000W 643 646 50 60 70 80 90 100 8000 Lumen in Burning hours 2000 6000 0 4000 10000 HPI T 2000W 642 Life expectancy diagram 50 60 70 80 90 100 8000 Survivals in Burning hours 2000 6000 0 4000 10000 HPI T 1000W 2000W 643 646 50 60 70 80 90 100 8000 Survivals in Burning hours 2000 6000 0 4000 10000 HPI T 2000W 642 Cap Base 40 E40 Op...

Page 19: ...OEM Catalogue 2009 2010 3 19 HID Lamps HPI T ...

Page 20: ...ation Sports lighting floodlighting of buildings and monuments area lighting e g harbours and building sites canopy lighting e g petrol stations horticultural lighting Luminaires HPI T Plus lamps require a protective front glass System Can be run on HPI gear as well as on SON gear Plus concept The results in both light output and colour temperature are different Environment Good environmental choi...

Page 21: ...5 E40 SLV 35000 89 Cool White 4500 65 362 370 p20 Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTER HPI T Plus 250W 645 E40 SLV MT 250 45 2B H E40 H 8711500179890 0 161 kg 12 31 7 cm x 19 6 cm x 27 7 cm 8711500182975 179890 15 MASTER HPI T Plus 250W 645 E40 SLV MT 250 45 2B H E40 H 8711500179890 0 161 kg 8...

Page 22: ...mance during run up Lumen maintenance diagram 50 60 70 80 90 100 16000 Lumen in Burning hours 4000 12000 0 8000 20000 HPI T 250W 400W 643 645 Life expectancy diagram 50 60 70 80 90 100 16000 Survivals in Burning hours 4000 12000 0 8000 20000 HPI T 250W 400W 643 645 Photometric diagram HPI T Cap Base 40 E40 Operating position p20 ...

Page 23: ...OEM Catalogue 2009 2010 3 23 HID Lamps MASTER HPI T Plus ...

Page 24: ...g options with Plus concept and S and P types Adjustable atmosphere creation by using appropriate colour temperature Application High bay lighting e g industrial workshops exhibition halls hypermarkets shopping malls DIY stores churches airports and train stations Luminaires HPI Plus BU P and BUS P suitable for use in open luminaires For other HPI Plus lamps a protective front glass is required Sy...

Page 25: ...R HPI Plus 250W 745 BU E40 CRP ME 250 45 2A H E40 V 8711500181145 0 192 kg 20 58 3 cm x 40 1 cm x 24 6 cm 8711500210852 181145 05 MASTER HPI Plus 250W 745 BU E40 CRP ME 250 45 2A H E40 V 8711500181145 0 192 kg 24 58 3 cm x 40 1 cm x 24 6 cm 8711500200709 181145 30 MASTER HPI Plus 250W 745 BU P E40 CRP ME S 250 45 2A H E40 V 8711500202062 0 19 kg 12 47 5 cm x 30 6 cm x 24 6 cm 8711500202079 202062 ...

Page 26: ...00 5 1 2 3 4 Ila Wla Vla HPI Lamp performance during run up Lumen maintenance diagram 50 60 70 80 90 100 16000 Lumen in Burning hours 4000 12000 0 8000 20000 HPI 250W 400W 743 767 Life expectancy diagram 50 60 70 80 90 100 16000 Survivals in Burning hours 4000 12000 0 8000 20000 HPI 250W 400W 743 767 Photometric diagram 180 150 210 0 30 330 60 90 120 300 270 240 180 150 210 0 30 330 60 90 120 300 ...

Page 27: ...OEM Catalogue 2009 2010 3 27 HID Lamps MASTER HPI Plus ...

Page 28: ...HPL installations with gear exchange Application City centres shopping centres and pedestrian areas residential areas road lighting and floodlighting Luminaires In the highly unlikely event of lamp breakage by incorrect use vandalism or end of life effects the luminaire housing should be able to contain heated glass metal and or ceramic particles System Must be used with a SON gear and SON ignitor...

Page 29: ...emperature K Colour Rendering Index Ra Chromaticity Coordinate X Chromaticity CoordinateY Operating Position MASTER CityWhite CDO TT 70W 828 E27 SLV 6300 88 Warm White 2800 83 452 402 any MASTER CityWhite CDO TT 100W 828 E40 SLV 8800 91 Warm White 2800 83 460 394 any MASTER CityWhite CDO TT 150W 828 E40 SLV 13500 92 Warm White 2800 85 460 403 any MASTER CityWhite CDO TT 250W 828 E40 SLV 22500 92 W...

Page 30: ... in 50 60 70 80 90 100 2000 12000 10000 18000 6000 16000 4000 14000 8000 CDO TT 70W 100W 150W Burning hours Lumen in 50 60 70 80 90 100 2000 12000 10000 16000 6000 4000 14000 8000 100 CDO TT 250W Life expectancy diagram Burning hours 100 50 60 70 80 90 100 Survivals in 2000 12000 10000 18000 6000 16000 4000 14000 8000 CDO TT 70W 100W 150W Burning hours 50 60 70 80 90 100 Survivals in 2000 12000 10...

Page 31: ...OEM Catalogue 2009 2010 3 43 HID Lamps MASTER CityWhite CDO TT ...

Page 32: ... High luminous output in comparison with white metal halide lamps using an additional colour filter Eliminates the need for expensive and fragile colour filters Application Decorative lighting of buildings landmarks statues monuments parks resorts and attractions Multi functional lighting for promotional seasonal and festive purposes at special events etc Luminaires Must be used in a closed lumina...

Page 33: ...000 p20 Ordering and packing data Type EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 Artcolour MH T 400W Blue E40 SLV 8711500201591 0 201 kg 6 24 7 cm x 19 cm x 35 6 cm 8711500201607 201591 10 Artcolour MH T 400W Green E40 SLV 8711500201638 0 201 kg 6 24 7 cm x 19 cm x 34 cm 8711500201645 201638 10 Artcolour MH T 400WViolet E40 SLV 8711500201652...

Page 34: ...5000 MH T 400W GR 50 60 70 80 90 100 4000 Lumen in Burning hours 1000 3000 0 2000 5000 MH T 400WVI Life expectancy diagram 50 60 70 80 90 100 4000 Survivals in Burning hours 1000 3000 0 2000 5000 MH T 400W BL 50 60 70 80 90 100 4000 Survivals in Burning hours 1000 3000 0 2000 5000 MH T 400W GR 50 60 70 80 90 100 4000 Survivals in Burning hours 1000 3000 0 2000 5000 MH T 400WVI Cap Base 40 E40 Oper...

Page 35: ...OEM Catalogue 2009 2010 3 31 HID Lamps Artcolour MH T ...

Page 36: ...creates a pleasant ambience with high visual comfort for players and spectators Continuous spectral distribution offers options for semi professional stadiums and area lighting Application Recreational sports and area floodlighting Luminaires MHN FC lamps require a protective UV absorbing front glass and correct thermal behaviour for optimal lamp performance Environment This product is RoHS compli...

Page 37: ...Y Operating Position MASTER MHN FC 1000W 740 230V XW UNP 93000 91 White 4100 65 379 383 p5 MASTER MHN FC 2000W 740 400V XW UNP 210000 102 White 4200 60 380 419 p5 Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTER MHN FC 1000W 740 230V XW UNP MD 1000 40 2B H XW 8711500214249 0 14 kg 1 43 cm x 9 5 cm x 8 5 c...

Page 38: ... Lumen in Burning hours 4000 6000 0 10000 2000 8000 MHN FC 1000W 740 750 50 60 70 80 90 100 Lumen in Burning hours 4000 6000 0 10000 2000 8000 MHN FC 2000W 740 Life expectancy diagram 50 60 70 80 90 100 Survivals in Burning hours 4000 6000 0 10000 2000 8000 MHN FC 1000W 740 750 50 60 70 80 90 100 Survivals in Burning hours 4000 6000 0 10000 2000 8000 MHN FC 2000W 740 Operating position p5 ...

Page 39: ...OEM Catalogue 2009 2010 3 35 HID Lamps MASTER MHN FC ...

Page 40: ...e burnershape allows optimised optic and luminaire design Optimal lamp service lifetime and energy savings initially and over lifetime Robust dedicated outdoor electronic Xtreme gear for long and reliable operation ensuring future proof outdoor installation Application Urban Public Lighting for city centres residential areas and roads System Designed for use with electronic gear only Lamps and gea...

Page 41: ...PGZ12 1CT 6800 114 White 2730 66 453 402 any MASTER CosmoWhite CPO TW 90W 728 PGZ12 1CT 10450 116 White 2880 66 444 403 any MASTER CosmoWhite CPO TW 140W 728 PGZ12 1CT 16500 118 White 2860 66 444 401 any Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTER CosmoWhite CPO TW 45W 628 PGZ12 1CT MT 45 28 2B H PGZ...

Page 42: ...00 600 50 150 250 100 200 700 300 W m n 5 m l nm CPO TW 90W CPO TW 140W Lumen maintenance diagram Lumen in 50 60 70 80 90 100 Burning hours 8000 20000 0 12000 24000 4000 16000 CPO TW Life expectancy diagram Survivals in 50 60 70 80 90 100 Burning hours 8000 20000 0 12000 24000 4000 16000 CPO TW Operating position any ...

Page 43: ...OEM Catalogue 2009 2010 3 39 HID Lamps MASTER CosmoWhite CPO TW ...

Page 44: ...trian areas residential areas road lighting and floodlighting Luminaires In the highly unlikely event of lamp breakage by incorrect use vandalism or end of life effects the luminaire housing should be able to contain heated glass metal and or ceramic particles System Must be used with a SON gear and SON ignitor Warm restart time can be up to fifteen minutes T15 ignitors are therefore advised Dimmi...

Page 45: ... 12500 86 Warm White 2800 82 460 403 any Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTER CityWhite CDO ET 70W 828 E27 SLV ME 70 28 1B H E27 8711500205445 0 052 kg 24 45 5 cm x 30 7 cm x 17 2 cm 8711500205452 205445 30 MASTER CityWhite CDO ET 100W 828 E40 SLV ME 100 28 1B H E40 8711500206794 0 128 kg 24 5...

Page 46: ...and floodlighting Luminaires In the highly unlikely event of lamp breakage by incorrect use vandalism or end of life effects the luminaire housing should be able to contain heated glass metal and or ceramic particles System Must be used in combination with a gear and an ignitor Must be used with a SON gear and SON ignitor in accordance with SON IEC standards ignition pulse between 1 8 kV and 2 5 k...

Page 47: ...Operating Position MASTERColour CDM TT 70W 942 E27 SLV 6400 85 Cool White 4200 90 369 370 any MASTERColour CDM TT 150W 942 E40 SLV 12000 83 Cool White 4200 90 386 369 any Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTERColour CDM TT 70W 942 E27 SLV MT 70 42 1A H E27 8711500209658 0 047 kg 12 16 6 cm x 13 ...

Page 48: ...ormance during run up t sec 0 40 80 120 160 200 600 120 240 360 480 Ila Wla Vla CDM TT 150W 942 Lamp performance during run up Photometric diagram 180 150 210 0 30 330 60 90 120 300 270 240 180 150 210 0 30 330 60 90 120 300 270 240 1000 500 1500 1000 500 1500 CDM TT 150W 180 150 210 0 30 330 60 90 120 300 270 240 180 150 210 0 30 330 60 90 120 300 270 240 500 250 750 500 250 750 CDM TT 70W Cap Ba...

Page 49: ...OEM Catalogue 2009 2010 3 49 HID Lamps MASTERColour CDM TT ...

Page 50: ... ZrAl getter ensures high lumen maintenance and few early failures Product Benefits Optimised performance for horticultural applications especially at lower lighting levels Optimizing plant development and quality with good leaf and bloom colour and extra branching Application Horticultural applications plant irradiation Environment Good environmental choice because of high energy efficiency and l...

Page 51: ...1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTER Agro 400W E40 SLV ST 400 H E E40 8711500707505 0 192 kg 12 16 9 cm x 22 5 cm x 31 1 cm 8711500183019 707505 15 Spectral power distribution Power 300 400 500 600 100 300 500 200 400 700 600 nm SON T Agro 400W Performance diagram Ila Wla Vla t 0 40 80 120 160 200 10 2 4 6 8 SON T Agro 400W Lamp performan...

Page 52: ...ficacy translated into high light output Product Benefits Optimised performance for horticultural applications High lumen maintenance safeguards a constant crop quality and quantity over life Application Horticultural applications plant irradiation Environment Good environmental choice because of high energy efficiency and long reliable life This product is RoHS compliant This product is covered b...

Page 53: ...STER GreenPower CGT 400W E40 SLV ST 400 H S E40 8711500201966 0 18 kg 12 22 5 cm x 16 9 cm x 31 1 cm 8711500201973 201966 15 MASTER GreenPower CGT 400W E40 UNP ST 400 H S E40 8711500202451 0 18 kg 60 60 cm x 40 cm x 32 5 cm 8711500202468 202451 75 MASTER GreenPower CGT 600W E40 SLV ST 600 H S E40 8711500202024 0 182 kg 12 22 5 cm x 16 9 cm x 31 1 cm 8711500202031 202024 15 MASTER GreenPower CGT 60...

Page 54: ...N T 100W 150W 250W 400W 50 60 70 80 90 100 Lumen in Burning hours 8000 24000 0 16000 32000 SON T 600W Life expectancy diagram 50 60 70 80 90 100 Survivals in Burning hours 8000 24000 0 16000 32000 SON T 100W 150W 250W 400W 50 60 70 80 90 100 Survivals in Burning hours 8000 24000 0 16000 32000 SON T 600W Cap Base 40 E40 Operating position any ...

Page 55: ...OEM Catalogue 2009 2010 3 55 HID Lamps MASTER GreenPower ...

Page 56: ...fetime High energy efficacy and absence of lead Pb makes this a sound environmental offer High luminous efficacy makes this the most energy efficient HPS lamp Application Road and residential lighting Decorative floodlighting illumination Industrial area lighting Recreational sports facilities indoor and outdoor Horticultural lighting Environment Good environmental choice because of high energy ef...

Page 57: ...tion MASTER SON T PIA Plus 50W 220 E27 SLV 4400 88 2000 25 540 420 any MASTER SON T PIA Plus 70W 220 E27 SLV 6600 91 2000 25 540 420 any MASTER SON T PIA Plus 100W 220 E40 SLV 10700 107 2000 25 535 420 any MASTER SON T PIA Plus 150W 220 E40 SLV 17500 110 2000 25 535 420 any MASTER SON T PIA Plus 250W 220 E40 SLV 33200 128 2000 25 530 420 any MASTER SON T PIA Plus 400W 220 E40 SLV 56500 138 2000 25...

Page 58: ...ram Ila Wla Vla t 15 0 5 10 20 40 80 100 120 140 60 20 SON T Plus 50W 70W E27 Lamp performance during run up t Ila Wla Vla 15 0 5 10 20 40 80 100 120 140 60 SON T Plus 100W 150W 250W E40 Lamp performance during run up t 15 0 5 10 20 40 80 100 120 140 60 20 Ila Wla Vla SON T Plus 400W E40 Lamp performance during run up Ila Wla Vla t 15 0 5 10 20 40 80 100 120 140 60 20 SON T Plus 600W E39 E40 Lamp ...

Page 59: ...ning hours 8000 24000 0 16000 32000 SON T 50W 70W 50 60 70 80 90 100 Survivals in Burning hours 8000 24000 0 16000 32000 SON T 100W 150W 250W 400W 50 60 70 80 90 100 Survivals in Burning hours 8000 24000 0 16000 32000 SON T 600W Photometric diagram 180 150 210 0 30 330 60 90 120 300 270 240 180 150 210 0 30 330 60 90 120 300 270 240 100 50 100 50 SON T Cap Base 27 E27 40 E40 Operating position any...

Page 60: ...oduct Benefits Superior technology results in a long and reliable lifetime high lumen maintenance and a reliable ignition over lifetime High energy efficacy and absence of lead Pb makes this a sound environmental offer High luminous efficacy makes this the most energy efficient HPS lamp Application Road and residential lighting Industrial lighting both indoor and outdoor Recreational sports facili...

Page 61: ... 250W 220 E40 SLV 31100 120 2000 25 530 420 any MASTER SON PIA Plus 400W 220 E40 SLV 55500 135 2000 25 525 425 any Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTER SON PIA Plus 70W 220 I E27 SLV SE 70 H I E27 8711500204264 0 055 kg 24 45 5 cm x 30 7 cm x 16 8 cm 8711500204271 204264 30 MASTER SON PIA Plus...

Page 62: ...SON PIA 50W 70W 50 60 70 80 90 100 Lumen in Burning hours 8000 24000 0 16000 32000 SON PIA 100W 150W 250W 400W Life expectancy diagram 50 60 70 80 90 100 Survivals in Burning hours 8000 24000 0 16000 32000 SON PIA 50W 70W 50 60 70 80 90 100 Survivals in Burning hours 8000 24000 0 16000 32000 SON PIA 100W 150W 250W 400W Operating position any ...

Page 63: ...OEM Catalogue 2009 2010 3 63 HID Lamps MASTER SON PIA Plus ...

Page 64: ...d reliable lifetime high lumen maintenance and a reliable ignition over lifetime Absence of mercury and lead makes this a environmentally sound offer Application Road and residential lighting Decorative floodlighting illumination Industrial area lighting Recreational sports facilities indoor and outdoor Environment Good environmental choice because of high energy efficiency long reliable life and ...

Page 65: ...eY Operating Position MASTER SON T PIA Hg Free 100W 221 E40 SLV 9000 88 2150 25 525 436 any MASTER SON T PIA Hg Free 150W 221 E40 SLV 15000 100 2150 25 525 436 any MASTER SON T PIA Hg Free 250W 221 E40 SLV 28000 110 2150 25 516 436 any MASTER SON T PIA Hg Free 400W 221 E40 SLV 48000 120 2150 25 519 436 any Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bul...

Page 66: ...e 400W E40 Lamp performance during run up Lumen maintenance diagram 50 60 70 80 90 100 Lumen in Burning hours 8000 24000 0 16000 32000 SON T 100W 150W 250W 400W Life expectancy diagram 50 60 70 80 90 100 Survivals in Burning hours 8000 24000 0 16000 32000 SON T 100W 150W 250W 400W Photometric diagram 180 150 210 0 30 330 60 90 120 300 270 240 180 150 210 0 30 330 60 90 120 300 270 240 100 50 100 5...

Page 67: ...OEM Catalogue 2009 2010 3 67 HID Lamps MASTER SON T PIA Hg Free ...

Page 68: ...um mercury amalgam Completely lead free lamps Product Benefits Superior technology results in a long and reliable lifetime high lumen maintenance and a reliable ignition over lifetime Absence of mercury and lead makes this a environmentally sound offer Application Road and residential lighting Industrial area lighting Recreational sports facilities indoor and outdoor Environment Good environmental...

Page 69: ...STER SON PIA Hg Free 250W 221 E40 SLV 27000 108 2150 25 516 436 any MASTER SON PIA Hg Free 400W 221 E40 SLV 48000 120 2150 25 519 436 any Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 MASTER SON PIA 50W 220 E27 SLV SE 50 H E E27 8711500201447 0 051 kg 24 45 5 cm x 30 7 cm x 16 8 cm 8711500201454 201447 30 MAS...

Page 70: ...00 32000 SON PIA 100W 150W 250W 400W Life expectancy diagram 50 60 70 80 90 100 Survivals in Burning hours 8000 24000 0 16000 32000 SON PIA 50W 70W 50 60 70 80 90 100 Survivals in Burning hours 8000 24000 0 16000 32000 SON PIA 100W 150W 250W 400W Photometric diagram 180 150 210 0 30 330 60 90 120 300 270 240 180 150 210 0 30 330 60 90 120 300 270 240 100 50 50 100 SON PIA Cap Base 27 E27 40 E40 Op...

Page 71: ...OEM Catalogue 2009 2010 3 71 HID Lamps MASTER SON PIA Hg Free ...

Page 72: ...olution in High Pressure Sodium offering good value for money Technical Features High Pressure Sodium lamp with clear outer bulb Clear tubular outer bulb Robust construction is vibration and shock resistant leading to a reliable life Dimming possible with dedicated gear Recommended gear page 3 170 www philips com OEM SON T Type C D L O SON T 70W 156 37 102 42 SON T 100W 210 46 132 44 SON T 150W 21...

Page 73: ...ct ID Lamp Voltage V Bulb Shape Bulb Finish Dimmable Lamp Current EM A Luminous Efficacy Lamp EM lm W SON T 70W 90 T31 Clear Yes 0 98 86 SON T 100W 100 T46 Clear 1 2 90 SON T 150W 100 T46 Clear Yes 1 8 100 SON T 250W 100 T46 Clear Yes 3 112 SON T 400W 100 T46 Clear Yes 4 6 120 SON T 1000W 105 T65 Clear Yes 10 6 130 Product ID Lamp Wattage EM W Recommended Ballast Net weight per piece g System Desc...

Page 74: ...n in High Pressure Sodium offering good value for money Technical Features Ovoid internally white coated outer bulb Robust construction is vibration and shock resistant leading to a reliable life Dimming possible with dedicated gear Require a ballast and ignitor except for SON 70W I lamps which have an internal ignitor Recommended gear page 3 170 www philips com OEM SON E27 Type C D SON 70W 156 71...

Page 75: ...p Voltage V Bulb Shape Bulb Finish Dimmable Lamp Current EM A Luminous Efficacy Lamp EM lm W SON 70W 90 B70 Coated Yes 0 98 80 SON 70W 90 B70 Coated Yes 0 98 80 SON 150W 100 BD90 Coated Yes 1 8 99 SON 250W 100 BD90 Coated Yes 3 108 SON 400W 105 BD120 Coated Yes 4 45 120 Product ID Lamp Wattage EM W Recommended Ballast Net weight per piece g System Description Luminance Average EM cd cm2 Ignition S...

Page 76: ...vibration and shock resistant leading to a reliable life Product Benefits The ideal balance between colour impression and energy efficacy Application City centres and residential areas Decorative floodlighting Commercial and industrial applications Recreational sports facilities indoor and outdoor Recommended gear page 3 170 www philips com OEM D L C O SON T Type CMax DMax LNom ONom SON T Comfort ...

Page 77: ...OS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 SON T Comfort 150W 621 E40 SLV STM 150 H E E40 8711500192288 0 134 kg 12 24 cm x 16 7 cm x 22 1 cm 8711500192707 192288 15 SON T Comfort 250W 621 E40 SLV STM 250 H E E40 8711500179852 0 166 kg 12 22 5 cm x 16 9 cm x 29 3 cm 8711500183187 179852 15 SON T Comfort 400W 621 E40 SLV STM 400 H E E40 871...

Page 78: ...acceptable colour rendering to create a pleasant ambience Robust construction is vibration and shock resistant leading to a reliable life Product Benefits The ideal balance between colour impression and energy efficacy Application City centres and residential areas Commercial and industrial applications Recommended gear page 3 170 www philips com OEM D C SON Type CMax DMax SON Comfort 150W 250W 62...

Page 79: ... 513 419 any SON Comfort 400W 621 E40 SLV 37000 93 2150 65 513 419 any Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 SON Comfort 150W 621 E40 SLV SEM 150 H E E40 8711500182166 0 172 kg 12 40 3 cm x 30 5 cm x 26 9 cm 8711500182173 182166 15 SON Comfort 250W 621 E40 SLV SEM 250 H E E40 8711500182197 0 18 kg 12 ...

Page 80: ...ion is vibration and shock resistant leading to a reliable life Product Benefits Instant and cost effective upgrade of light level and reduction of energy use replacing HPL Application Road and residential lighting Commercial and industrial applications System Require an HPL gear without ignitor Recommended gear page 3 170 www philips com OEM D C SON H Type CMax DMax SON H 68W 220 E27 SLV 164 4 71...

Page 81: ...0400 92 2000 25 532 416 any SON H 220W 220 E40 SLV 20000 91 2000 25 530 410 any SON H 350W 220 E40 SLV 34000 97 2000 25 525 415 any Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 SON H 68W 220 E27 SLV SEQ 70 H E27 8711500213990 0 055 kg 24 45 6 cm x 30 8 cm x 17 cm 8711500214171 213990 30 SON H 110W 220 E27 SL...

Page 82: ...50 60 70 80 90 100 16000 Lumen in Burning hours 4000 12000 0 8000 24000 6000 SON H 220W 350W Life expectancy diagram 50 60 70 80 90 100 28000 Survivals in Burning hours 8000 20000 0 16000 32000 12000 4000 24000 SON H 110W 50 60 70 80 90 100 16000 Survivals in Burning hours 4000 12000 0 8000 24000 6000 SON H 220W 350W Cap Base 27 E27 40 E40 Operating position any ...

Page 83: ...OEM Catalogue 2009 2010 3 83 HID Lamps SON H ...

Page 84: ...es these the most efficient light sources Application Road lighting railway marshalling yards and crossings airports harbours and docks quarries foundries and rolling mills Security and orientation lighting System On HF electronic gear SOX E have even higher efficacy saving up to 40 system energy Environment Good environmental choice because of highest energy efficiciency This product is covered b...

Page 85: ... EOC 8711500 MASTER SOX E 18W BY22d 1SL LSE E18 BY22d 8711500192806 150 gr 12 24 cm x 18 cm x 27 5 cm 8711500193407 192806 15 MASTER SOX E 26W BY22d SLV LSE E26 BY22d 8711500179746 225 gr 12 25 cm x 19 cm x 39 cm 8711500182692 179746 15 MASTER SOX E 36W BY22d SLV LSE E36 BY22d 8711500179760 300 gr 12 25 cm x 19 cm x 50 5 cm 8711500182739 179760 15 MASTER SOX E 66W BY22d SLV LSE E66 BY22d H 8711500...

Page 86: ...ance diagram 50 60 70 80 90 100 Lumen in Burning hours 6000 18000 0 12000 24000 SOX E Life expectancy diagram 50 60 70 80 90 100 Survivals in Burning hours 6000 18000 0 12000 24000 SOX E Photometric diagram 180 150 210 0 30 330 60 90 120 300 270 240 180 150 210 0 30 330 60 90 120 300 270 240 100 50 100 50 SOX E Cap Base 22 BY22d Operating position h110 p20 ...

Page 87: ...OEM Catalogue 2009 2010 3 87 HID Lamps MASTER SOX E ...

Page 88: ...oduct Benefits High luminous efficacy leads to low energy consumption Application Road lighting railway marshalling yards and crossings airports harbours and docks quarries foundries and rolling mills Security and orientation lighting System On HF electronic gear SOX have even higher efficacy saving up to 40 system energy Recommended gear page 3 170 www philips com OEM D C SOX Type CMax DMax SOX 3...

Page 89: ...k packing EOC 8711500 SOX 35W BY22d 1SL LS 35 BY22d 8711500179739 217 gr 12 25 cm x 19 cm x 39 cm 8711500182678 179739 15 SOX 55W BY22d 1SL LS 55 BY22d 8711500179753 300 gr 12 25 cm x 19 cm x 50 5 cm 8711500182715 179753 15 SOX 90W BY22d 1SL LS 90 BY22d H 8711500179777 483 gr 12 30 cm x 22 5 cm x 61 cm 8711500182753 179777 15 SOX 135W BY22d 1SL LS 135 BY22d H 8711500179791 708 gr 12 30 cm x 22 5 c...

Page 90: ...en maintenance diagram 50 60 70 80 90 100 Lumen in Burning hours 6000 18000 0 12000 24000 SOX Life expectancy diagram 50 60 70 80 90 100 Survivals in Burning hours 6000 18000 0 12000 24000 SOX Cap Base 22 BY22d Operating position h110 p20 ...

Page 91: ...OEM Catalogue 2009 2010 3 91 HID Lamps SOX ...

Page 92: ...dering Higher efficacy than standard HPL Product Benefits Creates a comfortable atmosphere at limited investment High safety level thanks high light output Application Public roads and residential areas factories transport sector and industrial area lighting Recommended gear page 3 170 www philips com OEM D C HPL E26 E27 E40 Type CMax DMax HPL Comfort 50W 534 E27 SG SLV 130 56 HPL Comfort 80W 534 ...

Page 93: ... any HPL Comfort 250W E40 HG CRP 14200 57 White 3300 51 419 392 any HPL Comfort 400W E40 HG CRP 24200 61 White 3500 47 413 392 any Ordering and packing data Type ILCOS EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 HPL Comfort 50W 534 E27 SG SLV QE 50 35 3 H E27 8711500180872 0 045 kg 24 24 5 cm x 18 5 cm x 27 cm 8711500194077 180872 30 HPL Comfo...

Page 94: ...6000 Lumen in Burning hours 4000 12000 0 8000 20000 HPL 50W 80W 125W 250W 400W Life expectancy diagram 50 60 70 80 90 100 16000 Survivals in Burning hours 4000 12000 0 8000 20000 HPL 50W 80W 125W 250W 400W Photometric diagram 180 150 210 0 30 330 60 90 120 300 270 240 180 150 210 0 30 330 60 90 120 300 270 240 100 50 50 100 HPL Comfort 250W Cap Base 27 E27 40 E40 Operating position any ...

Page 95: ...OEM Catalogue 2009 2010 3 95 HID Lamps HPL Comfort ...

Page 96: ...cury lamp Equipped with 1 electrode to ensure quick and reliable ignition Single ended gas filled glass bulb HG SG with a quartz mercury vapour discharge tube Internally coated ovoid outer bulb providing a cool bluish white light with reasonable colour qualities Recommended gear page 3 170 www philips com OEM HPL N Type C D HPL N 50W 129 55 HPL N 80W 154 70 HPL N 125W 172 75 HPL N 250W 227 90 HPL ...

Page 97: ...7496 HPL N 400W 542 E40 6 45 3900 22000 ANY 9280 535 07496 Product ID Lamp Voltage V Bulb Finish Lamp Current EM A Luminous Efficacy Lamp EM lm W Lamp Wattage EM W Soft Glass Hard Glass HPL N 50W 542 95 Coated 0 61 36 50 SG HPL N 80W 542 115 Coated 0 8 44 5 84 SG HPL N 125W 542 125 Coated 1 15 50 125 SG HPL N 250W 542 135 Coated 2 1 51 250 HG HPL N 400W 542 140 Coated 3 25 55 400 HG Product ID Rec...

Page 98: ...s on mains voltage without additional gear Combines a continuous spectrum from the incandescent source and a line spectrum from the high pressure mercury source It is recommended to protect ML against water splashes ML lamps are not dimmable Recommended gear page 3 170 www philips com OEM ML B22 Type C D 160W B22 165 75 100W E27 154 70 160W E27 172 75 250W E27 216 90 250W E40 226 90 500W E40 289 1...

Page 99: ...00 9280 962 57296 ML250W E40 12 SG 65 3400 5400 9286 010 09288 ML500W E40 6 HG 48 3700 13000 9280 970 57796 Product ID Voltage Bulb Finish Lamp Current EM A Luminous Efficacy lamp EM Lm W Net weight per piece g Ignition Supply Voltage min V ML100W 220 230V coated 0 46 10 5 52 180 ML160W 220 230V coated 0 76 19 64 180 ML160W 220 230V coated 0 76 19 61 180 ML250W 225 235V coated 1 2 21 184 180 ML250...

Page 100: ......

Page 101: ... gear Electronic HID gear Many of the latest lamps can only be operated on modern electronic control gear The use of electronic gear is generally advised for most lamp types because of the many advantages it brings to our end users High system efficiency to save energy Lower maintenance costs due to enhanced lumen maintenance and practical lamp life Compact size and low weight provide design flexi...

Page 102: ...MASTERColour New 3 102 OEM Catalogue 2009 2010 ...

Page 103: ...ium gear Philips offers conventional ballasts with internal thermal protection These types can be recognised by the TS indication For the whole range of lamps a full range of electronic ignitors is offered Philips prefers and advice customers to use the so called by Philips developed semi parallel ignitors also called impulser type Together with the gear these ignitors induces ignition pulses whic...

Page 104: ... connections with push button release Simple installation and cabling Applications Road tunnel lighting Residential lighting Indoor and outdoor applications recommended outdoor luminaire classification IP 23 Quality Philips Quality assures optimum quality regarding System supplier As manufacturers of lamps and electronic control gear Philips ensures that from the earliest development stage optimum...

Page 105: ...bient Ignition Voltage kV Cable Cap outputwires mutual pF HID P 70 S SON CDO 220 240V 1 70 50 60 220 240 90 100 50 4 5 120 HID P 100 S SON CDO 220 240V 1 100 50 60 220 240 90 100 50 4 50 120 HID P 150 S SON CDO 220 240V 1 150 50 60 220 240 90 100 50 4 50 120 Ordering and packing data Type EAN code 1 piece Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 HID P 70 S ...

Page 106: ...ine and Neutral Ensure that the Neutral is reconnected again after abovementioned test is carried out and before the installation is put into operation Inrush current Conversion table for max quantities of drivers on other types of Miniature Circuit Breaker MCB type Rating Relative number of drivers B 16 A 100 see table above B 10 A 63 C 16 A 170 C 10 A 104 L I 16 A 108 L I 10 A 65 G U II 16 A 212...

Page 107: ...OEM Catalogue 2009 2010 3 107 HID Gear HID PrimaVision SON and CDO ...

Page 108: ...ditions such as overtemperature and end of lamp life Suitable for use in outdoor luminaires Cage clamp terminal connections with push button release Simple installation and cabling Applications Road tunnel lighting Residential lighting Indoor and outdoor applications recommended outdoor luminaire classification IP 23 Quality Philips Quality assures optimum quality regarding System supplier As manu...

Page 109: ... packing EAN code bulk packing EOC 8711500 HID D 1 10V 100 S CDO 220 240V 50 60Hz 0 725 kg 10 39 8 cm x 16 cm x 11 1 cm 8711500931337 931320 30 HID D 1 10V 100 S SON 220 240V 50 60Hz 0 725 kg 10 39 8 cm x 16 cm x 11 1 cm 8711500749062 749055 30 HID D 1 10V 150 S CDO 220 240V 50 60Hz 0 725 kg 10 39 8 cm x 16 cm x 11 1 cm 8711500538109 538093 30 HID D 1 10V 150 S SON 220 240V 50 60Hz 0 725 kg 10 39 ...

Page 110: ...wer indication 60 100 Regulating light level see graph 50 100 EMC attention should be given with cable 3 mtr Run up time and fading down up rates are determined to guarantee reliable lamp operations Inrush current Conversion table for max quantities of drivers on other types of Miniature Circuit Breaker MCB type Rating Relative number of drivers B 16 A 100 see table above B 10 A 63 C 16 A 170 C 10...

Page 111: ...OEM Catalogue 2009 2010 3 111 HID Gear HID DynaVision SON and CDO ...

Page 112: ...ult conditions such as overtemperature and end of lamp life Suitable for use in outdoor luminaires Cage clamp terminal connections with push button release Simple installation and cabling Can operate SDW 100W lamps but only 100 power no dimming possible Applications Road tunnel lighting Residential lighting Indoor and outdoor applications recommended outdoor luminaire classification IP 23 Quality ...

Page 113: ...or operation 180 264V Mains frequency 50 60 Hz Power factor 100 power 0 98 Power factor 35 power 0 93 Earth leakage current 0 2 mA per driver Overvoltage protection 48 hrs at 325Vac 2 hrs at 366Vac 5 min at 400Vac Lamp operation Operation frequency typical 125 Hz Ignition voltage 3 4 kV Cable capacity SON 100 150W lamps 2 7 kV Max 1 nF CDO lamps 3 3 kV Max 0 5 nF Air and creepage distance from any...

Page 114: ...ve B 10 A 63 C 16 A 170 C 10 A 104 L I 16 A 108 L I 10 A 65 G U II 16 A 212 G U II 10 A 127 K III 16 A 254 K III 10 A 154 Notes 1 Data is based on a mains supply with an impedance of 400 mΩ equal to 15 m cable of 2 5 mm2 and other 20 m to the middle of the power distribution under worst case conditions With an impedance of 800 mΩ the number of drivers can be increased by 10 2 Measurements will be ...

Page 115: ...OEM Catalogue 2009 2010 3 115 HID Gear HID DynaVision DALI SON and CDO ...

Page 116: ...esidential tunnels Climatic suitability restricted to built in situations where relative humidity is limited luminaire classification min IP 54 Quality Philips Quality assures optimum quality regarding System supplier As manufacturers of lamps and electronic control gear Philips ensures that from the earliest development stage optimum lamp driver performance is maintained European standards Philip...

Page 117: ... 220 240 65 65 50 2 EXC 66 SOX E 220 240V 50 60Hz 1 66 5 50 60 220 240 65 65 50 2 EXC 91 SOX E 220 240V 50 60Hz 1 91 7 50 60 220 240 65 65 50 1 Ordering and packing data Type Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 EXC 35 SOX 220 240V 50 60Hz 0 266 kg 25 31 3 cm x 22 5 cm x 21 4 cm 8711500062390 062383 30 EXC 36 SOX E 220 240V 50 60Hz 0 267 kg 25 31 3 cm x...

Page 118: ...vents cycling of old lamps Size suitable for both luminaire and pole mounting and also for retrofit installations same footprint as electromagnetic systems Cage clamp terminal connections with pushbutton release Compact and environment friendly system Applications Road and street lighting Residential lighting City beautification Indoor and outdoor applications recommended outdoor luminaire classif...

Page 119: ... ºC T ambient Ignition Voltage kV Cable Cap outputwires mutual pF HID PXt 45 S CPO TW 220 240V 1 45 6 5 50 60 220 240 80 90 50 2 4 1000 HID PXt 60 S CPO TW 220 240V 1 60 7 3 50 60 220 240 80 90 50 2 4 1000 HID PXt 90 S CPO TW 220 240V 1 90 9 0 50 60 220 240 80 90 50 2 1 1000 HID PXt 140 S CPO TW 220 240V 1 140 12 7 50 60 220 240 80 90 50 2 1 1000 Ordering and packing data Type Weight Qty bulk pack...

Page 120: ... to use in Class 2 applications Stable flicker free lamp operation Self stopping facility prevents cycling of old lamps Size suitable for both luminaire and pole mounting and also for retrofit installations same footprint as electromagnetic systems Cage clamp terminal connections with pushbutton release Compact and environment friendly system Applications Road and street lighting Residential light...

Page 121: ... Line Frequency Hz Line Voltage V T case life ºC T case maximum ºC T ambient Ignition Voltage kV Cable Cap outputwires mutual pF HID DLS 1 60 7 3 50 60 220 240 70 70 50 2 4 1000 Ordering and packing data Type Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 HID DLS 6 Xt 60 S CPO TW 220 240V 0 85 kg 12 40 1 cm x 15 6 cm x 16 3 cm 8711500915092 915085 30 HID DLS 8 Xt...

Page 122: ...f the related lamps SON for continuous dimming in telecontrol or telemanagement system Can also be used as two level dimming system with switched line control when used in combination with an SDU Climatic suitability use in luminaries or poles under normal humid conditions IP 23 Quality Philips Quality assures optimum quality regarding System supplier As manufacturers of lamps and electronic contr...

Page 123: ... Voltage V T case life ºC T case maximum ºC T ambient HID DVC 250 SON 220 240V 50 60Hz 1 250 40 50 60 220 240 85 85 50 HID DVC 400 SON 220 240V 50 60Hz 1 400 50 50 60 220 240 85 85 50 BSH 250 400 L36 220 240V 50 60Hz 1 250 400 11 0 20 0 50 60 220 240 Electrical data Type T winding Delta T normal conditions ºC HID DVC 250 SON 220 240V 50 60Hz HID DVC 400 SON 220 240V 50 60Hz BSH 250 400 L36 220 240...

Page 124: ... never be disconnected otherwise circuitry could be damaged 2 Gear must be earthed 3 Power factor correction capacitor should be connected directly on the mains when installing this device in front of existing gear the original capacitor has to be removed Control characteristics Control input Control voltage input 1 10V Protected against mains voltage connection Yes Control resistance to be connec...

Page 125: ...OEM Catalogue 2009 2010 3 125 HID Gear HID DynaVision Control SON ...

Page 126: ... two level dimming is required combined with the advantages of electronic operation Quality Philips Quality assures optimum quality regarding System supplier As manufacturers of lamps and electronic control gear Philips ensures that from the earliest development stage optimum lamp gear performance is maintained European standards Philips HID electronic gears comply with all relevant international ...

Page 127: ...ulk packing Dimensions bulk packing EAN code bulk packing EOC 8727900 SDU 01 H 0 043 kg 20 20 cm x 17 5 cm x 11 cm 8711500747297 800845 00 SDU 01 L 0 043 kg 20 20 cm x 17 5 cm x 11 cm 8711500747273 800869 00 Electrical installation notes Mains operation With tolerances for performance 8 6 220 240V Control voltage 198 260V Max input current 160 mA Operation frequency 50 60 Hz Mechanical installatio...

Page 128: ...amps Applications Ideal for the following applications Recreational sports lighting indoor and outdoor Road and residential lighting Floodlighting of buildings and monuments Area lighting e g harbors building sites Canopy lighting e g petrol stations Horticulture Climatic suitability restricted to built in situations where relative humidity is limited Quality Philips Quality assures optimum qualit...

Page 129: ...elta T normal conditions ºC Input current with PF correct A BMH35L407ITS 1 35 8 1 8 3 50 230 240 130 65 70 0 24 BMH70L407ITS 1 70 12 7 13 9 50 230 240 130 65 70 0 45 BSN50L407ITS 1 50 11 3 11 9 50 230 240 130 70 75 0 3 BSN70L407ITS 1 70 12 8 13 2 50 230 240 130 65 0 6 BSN100L302I 1 100 14 9 50 230 130 75 0 6 BSN100L407ITS 1 100 13 5 14 1 50 230 240 130 70 75 0 6 BSN150L407I 1 150 16 3 50 230 240 1...

Page 130: ... cm x 14 9 cm x 13 7 cm 8711500738479 738479 30 BSN150L407ITS 1 82 6 24 2 cm x 14 9 cm x 13 7 cm 8711500739094 739087 30 BSN250L407I 2 9 6 24 2 cm x 17 5 cm x 13 7 cm 8711500738516 738516 30 BSN250L407ITS 2 9 6 24 2 cm x 17 5 cm x 13 7 cm 8711500739179 739162 30 BSN400L302I 4 3 2 21 cm x 17 9 cm x 9 cm 8711500746221 746221 30 BSN400L407ITS 4 3 2 21 cm x 17 9 cm x 9 cm 8711500934406 538635 31 BSN60...

Page 131: ...OEM Catalogue 2009 2010 3 131 HID Gear HID Basic BSN BMH semi parallel ignitor ...

Page 132: ...esidential lighting Recreational sports lighting indoor and outdoor Floodlighting of buildings and monuments Area lighting e g harbors building sites city centres shopping centres pedestrian areas Canopy lighting e g petrol stations Climatic suitability restricted to built in situations where relative humidity is limited Quality Philips Quality assures optimum quality regarding System supplier As ...

Page 133: ...z 1 150 250 13 2 27 1 50 230 240 130 40 80 0 85 1 4 BSN 250 400 L407 TS 230 240V 50Hz 1 250 400 18 7 32 4 50 230 240 130 40 60 1 40 2 20 Ordering and packing data Electrical installation notes Mains operation With tolerances for performance 8 6 With tolerances for operation 10 10 Operation frequency typical 50 Hz Power factor with specified capacitor minimum 0 85 Mechanical installation notes Wire...

Page 134: ...ins voltages frequencies on request Applications Ideal for the following applications Outdoor tunnels and parking areas Outside luminaire in the pole or electrical cabinet Road and residential lighting Area lighting e g harbors building sites city centres shopping centres pedestrian areas Climatic suitability use in luminaires under normal humidity conditions not drip proof Quality Philips Quality...

Page 135: ...50Hz 1 250 27 0 50 240 130 80 1 40 BSN 400 L33 TS 230V 50Hz 1 400 28 0 50 230 130 70 2 20 BSN 400 L34 TS 240V 50Hz 1 400 32 0 50 240 130 70 2 20 Ordering and packing data Type Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 BSN 50 L33 TS 230V 50Hz 1 kg 6 20 8 cm x 13 4 cm x 11 4 cm 8711500748232 748225 30 BSN 50 L34 240V 50Hz 1 kg 6 20 8 cm x 13 4 cm x 11 4 cm 871...

Page 136: ...llation notes Mains operation With tolerances for performance 8 6 With tolerances for operation 10 10 Operation frequency typical 50 Hz Power factor with specified capacitor minimum 0 85 Mechanical installation notes Wire cross section On the mains side 0 75 2 5 mm2 Strip length 6 mm BSN ...

Page 137: ...OEM Catalogue 2009 2010 3 137 HID Gear HID HeavyDuty BSN semi parallel ignitor ...

Page 138: ...y stations Road and residential lighting Recreational sports lighting indoor and outdoor Floodlighting of buildings and monuments Area lighting e g harbors building sites Canopy lighting e g petrol stations Climatic suitability restricted to built in situations where relative humidity is limited Quality Philips Quality assures optimum quality regarding System supplier As manufacturers of lamps and...

Page 139: ... data Type Number of Lamps x Rated Gear Lamp Power Power losses gear W Line Frequency Hz Line Voltage V T winding Delta T normal conditions ºC Input current with PF correct A BHL50L307 1 50 8 7 50 230 240 130 55 0 30 BHL80L307 1 80 11 6 50 230 240 130 75 0 45 BHL125L202 1 125 14 0 50 230 130 85 0 70 BHL125L307 1 125 14 0 50 230 240 130 85 0 70 BHL250L200 1 250 17 2 50 220 130 70 1 35 BHL250L202 1 ...

Page 140: ...41 737434 30 BHL250L202 1 85 kg 6 24 2 cm x 14 1 cm x 13 7 cm 8711500738172 738165 30 BHL250L307 1 85 kg 6 24 2 cm x 14 1 cm x 13 7 cm 8711500737236 737229 30 BHL400L200 2 95 kg 6 24 2 cm x 14 1 cm x 13 7 cm 8711500737502 737496 30 BHL400L202 2 95 kg 6 24 2 cm x 16 6 cm x 13 7 cm 8711500739216 739209 30 BHL400L307 2 95 kg 6 24 2 cm x 16 6 cm x 13 7 cm 8711500737267 737250 30 Electrical installatio...

Page 141: ...OEM Catalogue 2009 2010 3 141 HID Gear HID Basic BHL HPL HPI ...

Page 142: ...dings and monuments Area lighting e g harbors building sites Canopy lighting e g petrol stations High bay lighting e g industrial workshops exhibition halls hypermarkets shopping malls DIY stores churches airports railway stations Climatic suitability use in luminaires under normal humidity conditions not drip proof Quality Philips Quality assures optimum quality regarding System supplier As manuf...

Page 143: ...L40 230V 50Hz 1 250 19 5 50 230 130 85 1 35 BHL 400 L32 240V 50Hz 1 400 23 0 50 240 130 85 2 15 BHL 400 L40 230V 50Hz 1 400 22 0 50 230 130 80 2 15 Ordering and packing data Type Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 BHL 50 80 L48 230V 50Hz 1 25 kg 6 20 8 cm x 13 9 cm x 11 4 cm 8711500061768 919649 31 BHL 80 L32 240V 50Hz 1 kg 6 20 8 cm x 13 4 cm x 11 4 ...

Page 144: ...ration With tolerances for performance 8 6 With tolerances for operation 10 10 Operation frequency typical 50 Hz Power factor with specified capacitor minimum 0 85 Mechanical installation notes Wire cross section On the mains side 0 75 2 5 mm2 Strip length 6 mm BHL 50 80 80 80 125 125 BHL 250 400 ...

Page 145: ...OEM Catalogue 2009 2010 3 145 HID Gear HID HeavyDuty BHL HPL HPI ...

Page 146: ...ites industrial complexes Quality Philips Quality assures optimum quality regarding System supplier As manufacturers of lamps and electromagnetic control gear Philips ensures that from the earliest development stage optimum lamp gear performance is maintained European standards Philips HID electromagnetic gears comply with all relevant international rules and regulations Compliances and approvals ...

Page 147: ... 8 5 kg 1 22 cm x 13 cm x 10 5 cm 8711500062314 062314 00 BHL 1000 L78 230 240V 50Hz 8 5 kg 1 22 cm x 13 cm x 10 5 cm 8711500062376 062376 00 BSN 1000 L02 220V 50Hz 12 5 kg 1 27 cm x 13 cm x 10 5 cm 8711500062284 062284 00 BSN 1000 L43 220V 60Hz 12 5 kg 1 27 cm x 13 cm x 10 5 cm 8711500062277 062277 00 BSN 1000 L78 230 240V 50Hz 12 5 kg 1 27 cm x 13 cm x 10 5 cm 8711500062369 062369 00 BMH 1800 L4...

Page 148: ...OEM Catalogue 2009 2010 3 148 HID HighPower MH HPI HPL SON SN 56 SN 59 SN 61 SI 52 SI 54 Series ignitor ...

Page 149: ...OEM Catalogue 2009 2010 3 149 HID Gear HID HighPower MH HPI HPL SON ...

Page 150: ...ocks quarries foundries and rolling mills Security and orientation lighting Climatic suitability use in luminaires or poles under normal humidity conditions not drip proof Quality Philips Quality assures optimum quality regarding System supplier As manufacturers of lamps and electromagnetic control gear Philips ensures that from the earliest development stage optimum lamp gear performance is maint...

Page 151: ... data Type Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 BSX 26 L80 220V 50Hz 0 77 kg 24 27 8 cm x 23 cm x 13 5 cm 8711500943965 920461 30 BSX 26 L81 230V 50Hz 0 77 kg 24 27 8 cm x 23 cm x 13 5 cm 8711500943996 920492 30 BSX 26 L82 240V 50Hz 0 77 kg 24 27 8 cm x 23 cm x 13 5 cm 8711500944023 920515 30 BSX 35 L80 220V 50Hz 0 925 kg 24 27 8 cm x 23 cm x 13 5 cm 87...

Page 152: ...g railway marshalling yards and crossings airports harbors and docks quarries foundries and rolling mills Security and orientation lighting Climatic suitability use in luminaires or poles under normal humidity conditions not drip proof Quality Philips Quality assures optimum quality regarding System supplier As manufacturers of lamps and electromagnetic control gear Philips ensures that from the e...

Page 153: ... 0 50 Ordering and packing data Type Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 BSX 35 L40 230V 50Hz 0 9 kg 6 20 8 cm x 13 4 cm x 11 4 cm 8711500061911 919991 31 BSX 35 55 L32 240V 50Hz 0 9 kg 6 20 8 cm x 13 4 cm x 11 4 cm 8711500061928 920003 31 BSX 90 L32 240V 50Hz 1 26 kg 6 20 8 cm x 13 9 cm x 11 4 cm 8711500061874 915344 31 BSX 90 L40 230V 50Hz 1 26 kg 6 ...

Page 154: ... harbors and docks quarries foundries and rolling mills Security and orientation lighting Climatic suitability restricted to built in situations where relative humidity is limited Quality Philips Quality assures optimum quality regarding System supplier As manufacturers of lamps and electromagnetic control gear Philips ensures that from the earliest development stage optimum lamp gear performance ...

Page 155: ... 130 70 BSX 180 H96 220 240V 50Hz 1 180 32 0 50 220 240 130 70 Ordering and packing data Type Weight Qty bulk packing Dimensions bulk packing EAN code bulk packing EOC 8711500 BSX 36 H66 230 240V 50Hz 1 7 kg 12 27 5 cm x 21 cm x 17 5 cm 8711500938411 920034 30 BSX 55 H26 220 230V 50Hz 1 7 kg 12 27 5 cm x 21 cm x 17 5 cm 8711500932129 919960 30 BSX 90 H26 220 230V 50Hz 2 16 kg 10 33 cm x 20 cm x 13...

Page 156: ...lts in limited ballast coil volume and reduced weight with minimum watt losses Ballasts standard equipped with screw terminal blocks Earthing while mounting facilrty HID Standard ballasts Simple installation and cabling Applications For application with SON HPI PLUS which are used in road lighting public lighting industry lighting HID basic ballasts should be restricted to built in situations wher...

Page 157: ...N58 T5 230 50 1 80 0 40 18 250 1 20 0 85 17 0 70 I CDM 150W SN58TI5 MH 150W SN58TI5 BSN150L304I SON 150W SN58 T5 230 50 1 80 0 40 18 250 1 20 0 85 18 0 70 I BSN 150L304ITS SON 150W SN58 T5 230 50 1 80 0 40 18 250 1 20 0 85 18 0 70 I CDM 150W SN58TI5 MH 150W SN58TI5 BSN250L300I SON 250W SN58 T5 220 50 3 00 0 45 32 250 2 30 1 40 22 2 70 I BSN250L300I HPI Plus 250W SN58 220 50 t b a 0 45 32 250 2 30 ...

Page 158: ...6 26 0 x 15 0 x 16 1 11 5 504 871016303470630 BSN150L301ITS 1 85 6 26 0 x 15 0 x 16 1 11 5 504 871016303472030 BSN250L301I 2 7 6 26 0 x 17 5 x 16 1 16 5 288 871016303471330 BSN400L301I 4 45 4 22 6 x 19 0 x 19 8 19 192 871016303473730 BSN70L302I 1 1 6 21 0 x 14 8 x 14 2 7 630 BSN100L302I 1 2 6 18 2 x 12 5 x 13 3 7 5 630 871016303142230 BSN150L302I 1 85 6 26 0 x 15 0 x 16 1 11 5 504 871016303129330 ...

Page 159: ...9430 BSN150L301ITS 1 85 6 26 0 x 15 0 x 16 1 11 5 504 871016303121730 BSN250L301I 2 7 6 26 0 x 17 5 x 16 1 16 5 288 871016303120030 BSN400L301I 4 45 4 22 6 x 19 0 x 19 8 19 192 871016303132330 BSN100L302I 1 2 6 21 0 x 14 8 x 14 2 7 5 630 871016303141530 BSN150L302I 1 85 6 18 2 x 12 5 x 13 3 11 5 504 871016303128630 BSN150L302ITS 1 85 6 26 0 x 15 0 x 16 1 11 5 504 871016303102630 BSN250L302I 2 7 6 ...

Page 160: ...le mounting facility HID Standard ballasts Simple installation and cabling Applications For application with HPL HPI and HPI plus lamps such as industry lighting flood lighting sports lighting shop lighting public lighting road lighting HID basic ballasts should be restricted to built in situations where relative humidity is limited Compliances and approvals Safety EN 60922 Perfonmance EN 60923 Qu...

Page 161: ... 2 BHL 250L202 HPL 250W N A 230 50 2 13 0 55 18 250 2 2 1 35 18 5 75 1 HPL 250W SI51 230 50 2 15 0 55 18 250 2 2 1 35 18 5 75 2 BHL 250L204 HPL 250W N A 240 50 2 13 0 55 18 250 2 2 1 35 20 0 75 1 HPL 250W SI51 240 50 2 15 0 55 18 250 2 2 1 35 20 0 75 2 BHL 400L200 HPI 400W N A 220 50 3 25 0 60 25 250 3 9 2 15 21 8 70 1 HPI 400W SI51 220 50 3 40 0 55 28 250 3 9 2 15 23 8 75 2 BHL 400L201 HPI 400W N...

Page 162: ...3170530 BHL250L204 1 95 6 26 0 x 15 0 x 16 1 12 504 871016303111830 BHL400L204 2 95 6 26 0 x 17 5 x 16 1 18 288 871016303127930 BHL1000L202 6 1 16 5 x 12 5 x 13 3 7 871016305800930 Marking Made in China Ordering and packing data Type Weight Carton packing Qty pcs Carton packing Dimensions l x w x h cm Weight gross kg Pallet unit carton pcs EOC BHL125L200 1 2 6 18 2 x 12 5 x 13 3 9 630 871016303167...

Page 163: ...OEM Catalogue 2009 2010 3 163 HID Lamps HID Basic ballasts for HPL HPI plus lamps ...

Page 164: ...tor after 5 or 15 minutes with failing lamp to prevent cycling Compact dimensions and light weight Simple screw or click fit mounting or stud mounting for rapid assembly Applications Similar to those of the related lamps and gears Compliances and approvals Safety EN 61347 2 1 Performance EN 60927 RFI EN 55015 Harmonic current emissions EN 61000 3 2 EMC immunity EN 61547 Approval marking ENEC CE ma...

Page 165: ...57 SN 58 SN 58T5 SN 58T15 SND 58 84 5 65 0 41 0 38 0 4 3 SX 131 85 5 41 5 38 5 HID ignitors A1 A2 B1 C1 D1 Type A1Nom A2Nom B1Nom C1Nom D1Nom SN 56 SI 54 SN 61 SX 26 SND 88 114 5 95 0 41 0 38 0 4 3 A1 B1 C1 D1 M8 A2 Type A1Nom A2Nom B1Nom C1Nom D1Nom SND 57 S SN 57T15 S SI 51 S SN 57 S 89 0 70 0 41 5 38 5 4 3 SND 88 89 SN 58T5 S ...

Page 166: ...75 5 0 SND 88 400V 1 600 1 5 50 60 400 290 80 20 75 5 0 SND 90 480V 1 600 1 5 60 480 370 80 20 75 5 0 SN 57T15 220 240V 1 50 70 1 0 50 60 220 240 195 80 20 75 2 50 2 1 SN 57T5 220 240V 1 50 70 1 0 50 60 220 240 195 80 20 75 2 50 2 2 SN 58T15 220 240V 1 35 250 1 0 50 60 220 240 195 80 20 75 5 00 2 1 SN 58T15 S 220 240V 1 35 250 1 0 50 60 220 240 195 80 20 75 5 00 2 1 SN 58T5 220 240V 1 100 600 1 0 ...

Page 167: ...0Hz 8711500934062 0 064 kg 20 23 5 cm x 22 5 cm x 10 cm 8711500934079 934062 30 SND 91 480V 60Hz 8711500934062 0 064 kg 120 43 cm x 23 5 cm x 26 cm 8711500934697 934062 40 SN 57T15 220 240V 50 60Hz 8711500744692 0 046 kg 48 25 2 cm x 18 cm x 17 4 cm 8711500744708 744692 30 SN 57T15 S 220 240V 50 60Hz 8711500745972 0 048 kg 20 20 cm x 17 5 cm x 11 cm 8711500745989 745972 30 SN 57T5 220 240V 50 60Hz...

Page 168: ...OEM Catalogue 2009 2010 3 168 HID ignitors SI 52 SN 50 56 57 57 S 58 58 S 59 SU SUD SX 70 72 74 76 SX 131 73 SN 61 SND SI 51 51 S 54 ...

Page 169: ...OEM Catalogue 2009 2010 3 169 HID Gear HID ignitors ...

Page 170: ... PLUS MASTER SON PIA PLUS MASTER SON T PIA SON 50W SON 70W SON 100W SON 150W SON 250W SON 400W SON 600W SON 600W 400V SON 1000W HID DV 1 10V 070 S SON HID DV 1 10V 100 S SON HID DV 1 10V 150 S SON HID PV 070 SON CDO HID PV 100 SON CDO HID PV 150 SON CDO SON I SON I 50W SON I 70W SON H SON H 110W SON H 220W SON H 350W MASTER HPI PLUS HPI PLUS 250W BU HPI PLUS 400W BU HPI PLUS 400W BUS HPI T HPI T 1...

Page 171: ...0V BSN 50 BSN 70 10uF 250V 12uF 250V BHL 125 BHL 250 BHL 400 10uF 250V 18uF 250V 25uF 250V BHL 250 BHL 400 BHL 400 SI 51 SI 51 18uF 250V 25uF 250V 25uF 250V BHL 1000 BHL 2000 L78 BHL 2000 L76 SI 52 SI 52 SI 54 65uF 250V 125uF 250V 35uF 250V BHL 50 BHL 80 BHL 125 BHL 250 BHL 400 BHL 1000 7uF 250V 8uF 250V 10uF 250V 18uF 250V 25uF 250V 65uF 250V BMH 1800 L78 BHD 2000 L76 BHD 2000 L76 SN56 SN59 380MZ...

Page 172: ......

Reviews: