6.1 Susceptibility of display to external environment
Operating
- Temperature : 0 to 35 degree C
- Humidity : 80% max
- Altitude : 0-3658m
- Air pressure : 600-1100 mBAR
Storage
- Temperature : -20 to 60 degree C
- Humidity : 85% max ( < 40
℃
)
- Altitude : 0-12192m
- Air pressure : 300-1100 mBAR
Note: recommend at 5 to 35
°
C, Humidity less than 60 %
6.2 Display disturbances from external environment
According to IEC 801-2 for ESD disturbances
6.3 Display disturbances to external environment
Refer to Safety requirement
7. Reliability
7.1 Mean Time Between Failures
System MTBF (Excluding the LCD panel and CCFL) : 50,000 hrs
8. Quality assurance requirements
8.1 Acceptance test
According to MIL-STD-105D Control II level
AQL: 0.4 (major) 1.5 (minor)
(Please also refer to annual quality agreement)
Customer acceptance criteria: UAW0377/00
9. Serviceability
The serviceability of this monitor should fulfill the requirements which are prescribed in UAW-0346 and must be
checked with the check list UAT-0361.