(3). White screen
(4). Keypad Board
White screen
Measure Q406 base
is high level?
X401 oscillate
waveform is normal
Check Q406, Q405 is broken
or CN406 solder?
Check Correspondent
component.
Replace Panel
Check Correspondent
component.
Replace U401
OK
OK
Replace X401
OK
NG
NG
NG
NG
Check reset circuit of
U401 is normal