2.6 Power Supply
2.6.1 Features
•
AC line voltage range -
90Vac ~ 264Vac.
•
AC line frequency range -
50/60 Hz
±
3 Hz.
•
Input voltage transient -
300Vac for 10 seconds (China), 280Vac for 10 seconds (RoW).
•
Inrush current -
< 50 A at 240Vac cold start.
•
Earth leakage current -
< 1.0mA at 240Vac.
•
Power factor correction -
According to EN61000-3-2
2.6.2 Power consumption
It is equipped with two-stage power saving management. A delay of 5 seconds before entering the power saving
state is required to avoid misunderstanding of display resolution and timing mode changes.
•
Power on -
< 75w. (Test requirements refer to EN61000-3-2)
•
Active off -
< 2w at 120Vac / 240Vac.
•
Switch off -
< 2w at 120Vac / 240Vac.
2.6.3 Power saving conditions
The monitor enters DPM off mode when no H&V sync or one of H-sync / V-sync input is absent. No message
appears before entering DPM mode.
Timing 10.
Resolution 1280
x
960
Pixel clock
108.000 MHz
H. Frequency
60.000 kHz
H. Total
16.667 us
H. Active display
11.852 us
H. Back porch
2.889 us
H. Sync. Width
1.037 us
V. Frequency
60.000 Hz
V. Total display
16.667 ms
V. Active display
16.000 ms
V. Back porch
0.600 ms
V. Sync. Width
0.050 ms
H/V sync
polarity
+ / +
Summary of Contents for 107T7
Page 12: ...17 CDT Color Monitor 107T7 12 ...
Page 18: ...17 CDT Color Monitor 107T7 18 Fig 4 Fig 5 Fig 6 ...
Page 33: ...17 CDT Color Monitor 107T7 33 8 Mechanical of cabinet front dis assembly ...
Page 48: ...17 CDT Color Monitor 107T7 48 12 PCB Layout 12 1 Main PCB layout ...
Page 49: ...17 CDT Color Monitor 107T7 49 12 2 CRPC Board layout ...