17” CDT Color Monitor
107T7
13
4-3 Adjustment method
1. TP901, B + & HV voltage adjustment:
A. Chroma-2135 Signal generator or PC equivalent set mode 6, UVGA 640X480 pattern 101 .
B. Connect a DC Volt meter between TP902 and ground, then adjust VR902 to be 57
±
0.2 VDC for CPT and
LPDCRT.
C. Set the contrast and brightness max,and then adjust G2=600V for CPT CRT and G2=560V for LG CRT.
2. Factory preset Timings Adjustment:
A. Press MENU Key to show OSD window press Up or Down Key to switch the functional controls.
B. Press the Up Key to select the "ZOOM" function, then press the MENU Key. While do not release the
MENU Key until the OSD window changed to the Factory preset window.
C. The Factory preset window contains the following functional controls. Select one of the control. Then press
the Up/Down Key to adjust its value for the optimum picture.
SR
Save SRGB color
VO
V Offset
55
Save 5500C color
VG
V Gain
OS
User OSD size
HM
H size Max
LH
Brightness
HR
H Size Range
SB
SBQ
HS
HSUB Size Range
BI
Set Burn/in Off & On
HG
H Gain
SW
Set H/Freq Max 85~72K
HBRIOSD VC
DC
DCOffset ADJ
HBRIOSD HC
AB
ABL
User adjustment
OV
User OSD VC
Save and Exit
OH
User OSD HC
Degauss
EA
EHT Auto Adjustment
B-Bias
HE
HEHT Gain
G-Bias
VE
VEHT Gain
R-Bias
EO
EHT Offset
G-Gain
Summary of Contents for 107T7
Page 12: ...17 CDT Color Monitor 107T7 12 ...
Page 18: ...17 CDT Color Monitor 107T7 18 Fig 4 Fig 5 Fig 6 ...
Page 33: ...17 CDT Color Monitor 107T7 33 8 Mechanical of cabinet front dis assembly ...
Page 48: ...17 CDT Color Monitor 107T7 48 12 PCB Layout 12 1 Main PCB layout ...
Page 49: ...17 CDT Color Monitor 107T7 49 12 2 CRPC Board layout ...