PHILIPS Respironics Dreamstation User Manual Download Page 5

3

System Features and Contents

Important:

 Read and understand the entire manual for your therapy device before attempting to use this humidifier.

This figure illustrates many of the device features and contents, described in the following table.

#

Device Feature

Description

1

Humidifier

Connect your therapy device here.

2

Air Inlet Port

Connects to the outlet port on the therapy device.

3

Air Outlet Port

Connect the tubing here. 

4

Humidifier Lid Release Latch

Slide this latch to open the humidifier lid.

5

Water Tank

This one piece removable water tank holds the water for humidification. 

6

Maximum Fill Lines

The fill lines indicates the maximum water level for safe operation.

7

Humidifier Lid

Open the lid to access the water tank.

8

Humidifier Lid Seal

Seals the water tank to the humidifier lid.

9

Flexible Heated Tubing (optional)

The optional heated tube connects from the humidifier to the patient’s mask.

10

Humidifier Connector End

Connect this end of the tubing to the humidifier.

11

Heater Plate

Warms the water in the water tank.

12

Humidifier Release Button

Press this button to remove the humidifier from the therapy device. Refer to the 
“Disconnecting the Therapy Device” section of this manual to see this button.

13

Therapy Device

The heated humidifier connects to the back of the therapy device.

Note:

 This humidifier is specified for use with Philips Respironics DreamStation therapy devices only.

How to Contact Philips Respironics

Should you experience trouble with this equipment or require assistance setting up, using, or maintaining the device 
or accessories, please contact your home care provider. If you need to contact Philips Respironics directly, call 
the Philips Respironics Customer Service department at 1-800-345-6443 or 1-724-387-4000. You can also use the 

following address:

Respironics, Inc.
1001 Murry Ridge Lane
Murrysville, PA 15668

Summary of Contents for Dreamstation

Page 1: ...User manual DreamStation Heated Humidifier...

Page 2: ...ting the Tubing 4 Daily Use 5 Disconnecting the Tubing 6 Disconnecting the Therapy Device 7 Checking the Humidifier Lid Seal 7 Home Cleaning Instructions Water Tank 8 Home Cleaning Instructions Humidi...

Page 3: ...and discontinue use Contact your home care provider Before cleaning the humidifier always remove from the therapy device Empty and clean the water tank daily to prevent mold and bacteria growth Repair...

Page 4: ...ormance tubing 15 mm non heated performance tubing or optional 12 mm performance tubing For information related to the mask to be used including any need for a separate exhalation device consult the i...

Page 5: ...nal The optional heated tube connects from the humidifier to the patient s mask 10 Humidifier Connector End Connect this end of the tubing to the humidifier 11 Heater Plate Warms the water in the wate...

Page 6: ...against each other Connecting the Tubing 1 To attach the heated tube to the heated humidifier line up the connector 1 at the top of the heated tube to the top of the air outlet port 2 on the humidifie...

Page 7: ...k with water 2 no higher than the maximum fill line To avoid spilling the water level should not rise above the bottom of the tube 3 in the back of the water tank Note Clean the water tank before firs...

Page 8: ...having trouble with your mask refer to the instructions included with the mask 8 Refer to your therapy device manual for complete instructions on how to adjust both the Heated Humidifier and the opti...

Page 9: ...ompletely on both sides Allow the seal to air dry Inspect the seal for damage If the humidifier lid seal show signs of wear or damage contact your home care provider for a replacement To install or re...

Page 10: ...er plate by wiping it with a damp cloth Allow the platform to air dry before reconnecting to the therapy device 2 Inspect the humidifier base for any damage and replace it if necessary 3 Clean the hum...

Page 11: ...ng tears or damage etc Discard and replace if damaged 2 After the final water rinse described in the chemical disinfection instructions separately rinse the tank seal and heated tubing a minimum of 1...

Page 12: ...and humidifier lid seal are in present in their proper orientation and fully seated If a seal has come loose gently press around the edges of the seal to reseat it The humidifier is cracked or damage...

Page 13: ...ier seals and tube are connected properly and not leaking You may also choose to lower your humidifier and or heated tube settings or change the humidification mode from Fixed to Adaptive humidificati...

Page 14: ...eated humidifier is used with a Philips Respironics therapy device AC Power Consumption with 80W power supply 100 240 VAC 50 60 Hz 2 0 1 0 A DC Power Consumption 12 VDC 6 67 A Type of Protection Again...

Page 15: ...ized distributors of Respironics Inc products and Respironics Inc reserves the right to charge dealers for warranty service of failed product not purchased directly from Respironics Inc or authorized...

Page 16: ...1120833 1120833 R04 HM 12 05 2018 EN DOM...

Reviews: