Philio Z-Wave PHI PSM02 Quick Start Manual Download Page 5

1

group 1 is for receiving the report message, like triggered event, temperature, illumination etc. (max. 

nodes in group: 7)

2

group 2 is for light control, the device will send the “Basic Set” command to this group. (max. nodes 

in group: 7)

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can 

adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128 

… 255 the value sent in the application shall be the desired value minus 256. For example: to set a 

parameter to 200? it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value 

the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Basic Set Level (Parameter Number 2, Parameter Size 1) Setting the BASIC command value to turn on the 

light

Value

Description

255

0xFF(-1) turns on the light. (Default)

1 — 100 For dimmers 1 to 100 means the light strength

PIR Sensitivity (Parameter Number 3, Parameter Size 1) parameter to set the Sensitivity for the PIR (Passiv 

Infrared Sensor)

Value

Description

0

0 means disable the PIR motion;

1 — 99 1 means the lowest sensitivity, 99 means the highest sensitivity (Default 70)

Light Threshold (Parameter Number 4, Parameter Size 1) Setting the illumination threshold to turn on the 

light. When the event triggered and the environment illumination lower then the threshold, the device will 

turn on the light

Value

Description

0

0 means turn off illumination detected function And never turn on the light.

0 — 100

1 means darkest. 99 means brightest. 100 means turn off illumination detected function. 

And always turn on the light (Default 99)

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 5 

Summary of Contents for Z-Wave PHI PSM02

Page 1: ...able and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Con...

Page 2: ... controllers Product description The Z Wave 4 in 1 Sensor is designed with three detection sensors Door Window PIR Motion Temperature Illumination The Philio Multi Sensor is a Z Wave door window sensor motion sensor lighting sensor and temperature sensor in one package Thanks to this the PSM02 can be uses as a security device or home automation device e g to send an alarm when a motion is detected...

Page 3: ...work This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is i...

Page 4: ...sensor to send the warning message After powering up the divice needs several minutes to setup and work properly The device has a tamper switch which starts alarm when the device is forcibly removed Node Information Frame NI The Node Information Frame is the business card of a Z Wave device It contains information about the device type and the technical capabilities The inclusion and exclusion of ...

Page 5: ... Set Level Parameter Number 2 Parameter Size 1 Setting the BASIC command value to turn on the light Value Description 255 0xFF 1 turns on the light Default 1 100 For dimmers 1 to 100 means the light strength PIR Sensitivity Parameter Number 3 Parameter Size 1 parameter to set the Sensitivity for the PIR Passiv Infrared Sensor Value Description 0 0 means disable the PIR motion 1 99 1 means the lowe...

Page 6: ...window closed Bit 5 Disable auto turn off the light after door window opened to turn on the light Notice If bit2 is zero this setting is useless Bit 6 Enable temperature monitoring When this bit enable the temperature changed 3 degree Fahrenheit it will report And also the temperature over 140 degree Fahrenheit it will report every 64 seconds Default 4 PIR Re Detect Interval Time Parameter Number ...

Page 7: ... tick is 12 6 hours Default 12 Auto Report Temperature Time Parameter Number 13 Parameter Size 1 interval time for auto report the temperature Value Description 1 127 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Default 12 Command Classes Supported Command Classes Battery version 1 Association version 2 Configuration version 1 Manufacturer Specific version 2 Versio...

Page 8: ...s of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines Th...

Reviews: