Open the casing and dissemble the front part of the case.

Put the included CR123A battery into the battery compartment and close the casing.

The sensor consists of two parts; a Detector and a Magnet. They are designed to be fitted to doors or 

windows with the Magnet mounted on the opening part and the Detector mounted on the fixed frame. If 

used for motion detection mount the device at a wall at about 2 m above surface. To enhance operation 

place the device on a position which can detect the room widely. Mount the device with the included screws 

or the adhesive tape on a plane surface.

Behavior within the Z-Wave network

I

 On factory default the device does not belong to any Z-Wave network. The device needs to join an 

existing wireless network to communicate with the devices of this network. This process is called Inclusion

Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the 

primary controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion 

mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or 

exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave 

the network. Leaving the network - i.e. being excluded - sets the device back to factory default.

If the device already belongs to a network, follow the exclusion process before including it in your network. 

Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to 

be reset first.

Tripple Click the Temper Switch on the backside confirms inclusion and exclusion.

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 3 

Summary of Contents for Z-Wave PHI PSM02

Page 1: ...able and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Con...

Page 2: ... controllers Product description The Z Wave 4 in 1 Sensor is designed with three detection sensors Door Window PIR Motion Temperature Illumination The Philio Multi Sensor is a Z Wave door window sensor motion sensor lighting sensor and temperature sensor in one package Thanks to this the PSM02 can be uses as a security device or home automation device e g to send an alarm when a motion is detected...

Page 3: ...work This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is i...

Page 4: ...sensor to send the warning message After powering up the divice needs several minutes to setup and work properly The device has a tamper switch which starts alarm when the device is forcibly removed Node Information Frame NI The Node Information Frame is the business card of a Z Wave device It contains information about the device type and the technical capabilities The inclusion and exclusion of ...

Page 5: ... Set Level Parameter Number 2 Parameter Size 1 Setting the BASIC command value to turn on the light Value Description 255 0xFF 1 turns on the light Default 1 100 For dimmers 1 to 100 means the light strength PIR Sensitivity Parameter Number 3 Parameter Size 1 parameter to set the Sensitivity for the PIR Passiv Infrared Sensor Value Description 0 0 means disable the PIR motion 1 99 1 means the lowe...

Page 6: ...window closed Bit 5 Disable auto turn off the light after door window opened to turn on the light Notice If bit2 is zero this setting is useless Bit 6 Enable temperature monitoring When this bit enable the temperature changed 3 degree Fahrenheit it will report And also the temperature over 140 degree Fahrenheit it will report every 64 seconds Default 4 PIR Re Detect Interval Time Parameter Number ...

Page 7: ... tick is 12 6 hours Default 12 Auto Report Temperature Time Parameter Number 13 Parameter Size 1 interval time for auto report the temperature Value Description 1 127 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Default 12 Command Classes Supported Command Classes Battery version 1 Association version 2 Configuration version 1 Manufacturer Specific version 2 Versio...

Page 8: ...s of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines Th...

Reviews: