1. Controllers control actuators
2. Actuators report change of status back to controller
3. Sensors report change of status of measured values to controller
4. Sensors directly control actuators
5. Actuators control other actuators
6. Remote controls send signals to static controllers to trigger scenes or other actions
7. Remote controls control other actuators.

There are two different role a controller can have. There is always one single primary controller that is managing the 

network and including/excluding devices. The controller may have other functions - like control buttons - as well. All other 

controllers don't manage the network itself but can control other devices. They are called secondary controllers. The 

image also shows that its not possible to operate a sensor just from a remote control. Sensors only communicate with 

static controllers.

Product description

The Z-Wave 4 in 1 Sensor is designed with three detection sensors:

Door-/Window

PIR/Motion

Temperature

Illumination

The Philio Multi Sensor is a Z-Wave door/ window sensor, motion sensor, lighting sensor and temperature 

sensor in one package. Thanks to this the PSM02 can be uses as a security device or home automation 

device, e.g. to send an alarm when a motion is detected, turn the light on/ off automatically at night or to 

adjust the heater.

The product consists of two elements - the detector and the magnet. The magnet is mounted on the moving 

part of the window or of the door. The other part is placed on the frame.

Batteries

The unit is operated by batteries. Use only batteries of correct type. Never mix old and new batteries in the 

same device. Used batteries contain hazardous substances and should not be disposed of with household 

waste!

Battery Type:  1 * CR123A

Installation Guidelines

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 2 

Summary of Contents for Z-Wave PHI PSM02

Page 1: ...able and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Con...

Page 2: ... controllers Product description The Z Wave 4 in 1 Sensor is designed with three detection sensors Door Window PIR Motion Temperature Illumination The Philio Multi Sensor is a Z Wave door window sensor motion sensor lighting sensor and temperature sensor in one package Thanks to this the PSM02 can be uses as a security device or home automation device e g to send an alarm when a motion is detected...

Page 3: ...work This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is i...

Page 4: ...sensor to send the warning message After powering up the divice needs several minutes to setup and work properly The device has a tamper switch which starts alarm when the device is forcibly removed Node Information Frame NI The Node Information Frame is the business card of a Z Wave device It contains information about the device type and the technical capabilities The inclusion and exclusion of ...

Page 5: ... Set Level Parameter Number 2 Parameter Size 1 Setting the BASIC command value to turn on the light Value Description 255 0xFF 1 turns on the light Default 1 100 For dimmers 1 to 100 means the light strength PIR Sensitivity Parameter Number 3 Parameter Size 1 parameter to set the Sensitivity for the PIR Passiv Infrared Sensor Value Description 0 0 means disable the PIR motion 1 99 1 means the lowe...

Page 6: ...window closed Bit 5 Disable auto turn off the light after door window opened to turn on the light Notice If bit2 is zero this setting is useless Bit 6 Enable temperature monitoring When this bit enable the temperature changed 3 degree Fahrenheit it will report And also the temperature over 140 degree Fahrenheit it will report every 64 seconds Default 4 PIR Re Detect Interval Time Parameter Number ...

Page 7: ... tick is 12 6 hours Default 12 Auto Report Temperature Time Parameter Number 13 Parameter Size 1 interval time for auto report the temperature Value Description 1 127 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Default 12 Command Classes Supported Command Classes Battery version 1 Association version 2 Configuration version 1 Manufacturer Specific version 2 Versio...

Page 8: ...s of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines Th...

Reviews: